Process Data set: Zaptec PRO MID (Norway) (en) en

Key Data Set Information
Location NO
Geographical representativeness description Europe
Reference year 2025
Name
Zaptec PRO MID (Norway)
Use advice for data set The analysis is a cradle-to-grave study made for one charger manufactured , installed and used under ordinary conditions over its lifetime. Modules A1-A5 are included in the analysis. It includes the extraction and production of raw materials, transportation to the factory, the production process itself, transportation to market and installation of the product. B6 is the operational energy usage based on a normal use. C1-C4, D are mandatory modules which include end of life treatment of materials and the benefits from recycling.
Technical purpose of product or process Zaptec Pro MID is an alternating current (AC) wall or column mounted charging station in accordance with IEC61851-1, EVSE mode 2. The charging station is for large scale deployment such as public parking, offices, multi-family housing etc.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.2332237698 kg
  • Carbon content (biogenic) - packaging: 0.137183906342 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-10-31 - 2030-10-31
Technological representativeness
Technology description including background system Dimensions: 392 mm W: 258 mm D: 112 mm Installation circuit: Max. 63A circuit breaker on installation circuit for charging stations. Backplate connection box Cable cross section 2.5–10 mm2 Cable diameter 10–18,5mm Installation network, Voltages: TN, IT and TT 230VAC ±10% 400VAC ±10% Max. current and charging output: 22 kW at 32A / 3-phase (applicable to TN networks only)* 12,7 kW at 32A / 3-phase (IT network)* 7,4 kW at 32A / 1-phase (IT/TN network)* 3W at standby Integrated circuit breaker: Built-in 3 x 40A MCB (miniature circuit breaker) type C Charging socket: IEC 62196-2 Type 2 with integrated self-closing cover. Electronic lock can be locked permanently by the user. Earth fault protection: Built-in type B RCD Calibration and a self-test are carried out before the start of every charging cycle. RCD can be automatically reset by disconnecting from the charging connector. Integrated Power Meter: MID class B certified (EN 50470) Display showing total energy (kWh) Theft protection: The front cover of the Zaptec Pro can only be opened using a special tool. The charging cable can be locked permanently to the charging station. Load balancing: Together with other Zaptec Pro charging stations, available power in the installation will be distributed automatically between the devices and phases. Phase balancing: The charging station will dynamically select any single phase or 3-phase in a system with other Zaptec Pro charging stations, depending on the available power Communications interface and cloud connection/network: 4G LTE-M Wi-Fi 2.4 GHz, IEEE 802.11 b/g/n (channels 1-11) Powerline (PLC) – HomePlug Green PHY®, 10 Mbit/s Identification and configuration: Bluetooth 5.1 (BR/EDR/BLE) RFID/NFC reader – ISO/IEC 14443 A (Type A, 13.56 MHz) ISO/IEC 15693 (Mifare classic, 13.56 MHz) Plug and Charge - Hardware support for ISO15118 RGBW LED-circle for status of unit Standards and approvals: CE compliance in accordance with the Radio Equipment Directive 2014/53/EU and ROHS Directive 2011/65/EU, and compliance with IEC 61851-1 (TUV SÜD) and IEC 61851-21-2 Temperature range: –30°C to +40°C Degree of protection: IP54, indoor and outdoor use IK10 impact protection UL94 5VB flammability rating UV resistant Electrical protection Protection class I Overvoltage category III (4kV) Integration services Third-party integration alternatives (API, Webhooks) OCPP 1.6J cloud-to-cloud Message subscription

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 330.2
  • 0.1414
  • 58.72
  • 0.2514
  • 0.001689
  • 1485
  • 0
  • 0.02036
  • 0.4255
  • 0.511
  • -26.55
Input
  • 8.15
  • 0
  • 0
  • 0
  • -1.03
  • 0
  • 0
  • 0
  • -7.12
  • 0
  • 0
Input
  • 338.4
  • 0.1414
  • 58.72
  • 0.2514
  • -1.028
  • 1485
  • 0
  • 0.02036
  • -6.695
  • 0.511
  • -26.55
Input
  • 2.72E+3
  • 9.504
  • 3.252
  • 14.54
  • 0.08826
  • 7678
  • 0
  • 1.178
  • 2.623
  • 1.683
  • -178.3
Input
  • 3.663
  • 0
  • 0
  • 0
  • -0.1943
  • 0
  • 0
  • 0
  • -3.468
  • 0
  • -31.84
Input
  • 2724
  • 9.504
  • 3.252
  • 14.54
  • -0.106
  • 7678
  • 0
  • 1.178
  • -0.8459
  • 1.683
  • -210.1
Input
  • 1.231
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0129
  • 0.164
Input
  • 0.049
  • 0.0000444
  • 0.00004018
  • 0.00008411
  • 0.00005119
  • 108.3
  • 0
  • 0.000006811
  • 0.003547
  • 0.001426
  • -0.03767
Input
  • 0.008228
  • 0
  • 0.0002463
  • 0
  • 0.0004473
  • 25.72
  • 0
  • 0
  • -0.0006041
  • 0.1121
  • -0.5644
Input
  • 2.017
  • 0.001124
  • 0.4161
  • 0.001958
  • 0.00005343
  • 6.508
  • 0
  • 0.0001585
  • 0.004663
  • 0.001106
  • -0.1407
Output
  • 19.75
  • 0.01296
  • 0.02705
  • 0.02086
  • 0.00192
  • 1.154
  • 0
  • 0.001689
  • 0.0002981
  • 0.605
  • -0.04326
Output
  • 743
  • 0.2559
  • 0.623
  • 0.4403
  • 0.008869
  • 25.97
  • 0
  • 0.03565
  • 0.4025
  • 1.152
  • -2.052
Output
  • 0.005811
  • 0.00002967
  • 0.00002714
  • 0.00000461
  • 5.207E-7
  • 0.0548
  • 0
  • 3.733E-7
  • 0.00001481
  • 0.000001885
  • -0.0004597
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.008963
  • 0
  • 0.1312
  • 0
  • 0
  • 0
  • 0.3155
  • 0.00008713
  • -0.006958
Output
  • 0
  • 0
  • 0.004882
  • 0
  • 0.1823
  • 0
  • 0
  • 0
  • 0.9714
  • 0.000002131
  • -0.003187
Output
  • 0
  • 0
  • 0.003082
  • 0
  • 0.1284
  • 0
  • 0
  • 0
  • 1.492
  • 0.0001382
  • -0.006159
Output
  • 0
  • 0
  • 0.04663
  • 0
  • 1.943
  • 0
  • 0
  • 0
  • 22.58
  • 0.002091
  • -0.09318

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2725
  • 9.504
  • 3.252
  • 14.54
  • 0.08825
  • 7665
  • 0
  • 1.178
  • 2.622
  • 1.681
  • -207.3
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.07159
  • 0.000001853
  • 0.000007472
  • 0.000003389
  • 1.326E-7
  • 0.002724
  • 0
  • 2.745E-7
  • 0.000004045
  • 8.277E-7
  • -0.01554
Acidification potential, Accumulated Exceedance (AP)
  • 1.661
  • 0.005978
  • 0.001205
  • 0.003238
  • 0.00004856
  • 2.169
  • 0
  • 0.0002622
  • 0.001477
  • 0.0006906
  • -0.7311
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.3071
  • 0.0004034
  • 0.008856
  • 0.0007901
  • 0.5034
  • 2.612
  • 0
  • 0.00006397
  • 0.8562
  • 0.0001216
  • -0.0394
Global Warming Potential - fossil fuels (GWP-fossil)
  • 208.4
  • 0.6969
  • 0.2684
  • 1.036
  • 0.01043
  • 371.5
  • 0
  • 0.08385
  • 2.638
  • 0.2407
  • -12.6
Global Warming Potential - total (GWP-total)
  • 208.5
  • 0.6976
  • 0.2787
  • 1.037
  • 0.5138
  • 375
  • 0
  • 0.08395
  • 3.495
  • 0.242
  • -12.66
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.3768
  • 0.0002624
  • 0.001481
  • 0.0003659
  • 0.000001964
  • 0.864
  • 0
  • 0.00002963
  • 0.0007645
  • 0.001129
  • -0.02002
  • 209.2
  • 0.6973
  • 0.2764
  • 1.036
  • 0.01129
  • 375
  • 0
  • 0.0839
  • 2.639
  • 0.242
  • -12.23
Eutrophication potential - freshwater (EP-freshwater)
  • 0.2736
  • 0.00003947
  • 0.00008892
  • 0.00006867
  • 7.522E-8
  • 0.03967
  • 0
  • 0.00000556
  • 0.000003721
  • 0.000005828
  • -0.004121
Eutrophication potential - marine (EP-marine)
  • 0.2983
  • 0.001656
  • 0.0002125
  • 0.001092
  • 0.00002034
  • 0.2753
  • 0
  • 0.00008842
  • 0.0004353
  • 0.0002696
  • -0.03734
Eutrophication potential - terrestrial (EP-terrestrial)
  • 3.222
  • 0.01825
  • 0.002335
  • 0.01188
  • 0.0002124
  • 3.394
  • 0
  • 0.0009616
  • 0.004664
  • 0.001665
  • -0.5163
Photochemical Ozone Creation Potential (POCP)
  • 0.9528
  • 0.005908
  • 0.0007443
  • 0.005076
  • 0.00005607
  • 0.8607
  • 0
  • 0.000411
  • 0.001268
  • 0.0007629
  • -0.1489
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000009192
  • 1.184E-8
  • 7.627E-9
  • 2.142E-8
  • 1.245E-9
  • 0.00003146
  • 0
  • 1.734E-9
  • 3.127E-8
  • 1.018E-8
  • -0.009537
Water (user) deprivation potential (WDP)
  • 87.36
  • 0.0414
  • 17.85
  • 0.07143
  • 0.132
  • 1.152E+5
  • 0
  • 0.005784
  • 48.55
  • 4.413
  • -346.3

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 23.65
  • 0.01024
  • 0.1247
  • 0.01855
  • 0.0003426
  • 67.14
  • 0
  • 0.001502
  • 0.01495
  • 0.003534
  • -0.5337
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001217
  • 4.166E-8
  • 1.56E-8
  • 8.032E-8
  • 6.25E-10
  • 0.000005687
  • 0
  • 6.504E-9
  • 8.419E-9
  • 1.271E-8
  • -0.000001558
Potential Soil quality index (SQP) 2
  • 1064
  • 4.529
  • 0.7929
  • 8.656
  • 0.05637
  • 1851
  • 0
  • 0.7009
  • 0.9917
  • 4.505
  • -119.8
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000008312
  • 5.704E-9
  • 7.209E-9
  • 1.071E-8
  • 3.86E-10
  • 0.000005172
  • 0
  • 8.67E-10
  • 5.981E-7
  • 4.238E-9
  • -0.000002474
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.3E-7
  • 0
  • 2.57E-10
  • 0
  • 8E-12
  • 1.498E-7
  • 0
  • 0
  • 1.018E-8
  • 5.74E-10
  • -3.35E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 5447
  • 1.11
  • 2.778
  • 1.91
  • 0.1015
  • 5.37E+3
  • 0
  • 0.1546
  • 10.54
  • 113.1
  • -5336