Close Go back Collapse all sections
Process Data set: KSFS (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe.
Reference year 2024
Name
KSFS
Technical purpose of product or process Ducted particulate filter for Mini Pleat filter panels, Mini Pleat filter cells, and activated carbon filter cells. Fitting of filter elements for the separation of suspended particles in areas with critical requirements. For more information see: https://www.trox.de/en/ducted-particulate-filters-for-critical-requirements/ksfs-d27e8a0e089344fd Ducted particulate filters KSFS for critical requirements as filter casings for installation into the ductwork of ventilation systems. Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air; also for the fitting of activated carbon filter cells for the adsorption of gaseous odorous substances and contaminants. Filter casings are available as one-stage construction or two-stage construction for the fitting of fine dust filters as prefilter stage and of particulate filters as second filter stage. Ducted particulate filter KSFS with robust, doubled-edged connecting flanges with pre-drilled holes. Clamping mechanism made of stainless steel with tensioning lever for uniform sealing integrity between the casing and filter element. Filter casing with sealing integrity test facility, available with optional double-groove service board and plastic service bag for contamination-free filter change. The cover plate is fitted with a profiled seal and 4 clamping screws with star grips. Pressure measurement points are part of the supply package but must be set up on site by others. Leakage classes D according to EN 15727 and L1 according to EN 1886. Leakage test for every casing. Optional: Filter casing KSFS with explosion protection, use in areas with a potentially explosive atmosphere of zones 1 and 2, as well as zones 21 and 22 (Ex II 2G Ex IIC T6 Gb and Ex II 2D Ex IIIB T80 °C Db). The filter casings must be connected to the earth potential. All conductive and dissipative parts must be connected together and grounded. Conductive dusts are excluded from the application. Under no circumstances should metallic foreign materials enter the filter casing.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-04 - 2029-12-04
Technological representativeness
Technology description including background system For technical data see: https://www.trox.de/en/ducted-particulate-filters-for-critical-requirements/ksfs-d27e8a0e089344fd#technical-information

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 383.8
  • 2.086
  • 0.006021
  • 0.1304
  • 0.3476
  • -3.523
  • -51.64
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 383.8
  • 2.086
  • 0.006021
  • 0.1304
  • 0.3476
  • -3.523
  • -51.64
Input
  • 2.61E+3
  • 145.7
  • 1.113
  • 9.106
  • 2.327
  • -44.5
  • -378
Input
  • 130.9
  • 0
  • 0
  • 0
  • -129.8
  • 0
  • 0
Input
  • 2719
  • 145.7
  • 1.113
  • 9.106
  • -127.5
  • -44.5
  • -378
Input
  • 5.782
  • 0
  • 0.0005467
  • 0
  • 0
  • 0.003808
  • -0.06534
Input
  • 5.318
  • 0.07462
  • 0.0001481
  • 0.004663
  • 0.007786
  • 0.1969
  • 1.543
Input
  • 108.8
  • 0.2668
  • 0.00218
  • 0.01667
  • 0
  • 5.742
  • 44.42
Input
  • 1.961
  • 0.01558
  • 0.00005729
  • 0.0009738
  • 0.005089
  • -0.01027
  • -0.1348
Output
  • 1.75
  • 0.007514
  • 0.00003277
  • 0.0004696
  • 0
  • 0.1928
  • -0.2341
Output
  • 97.91
  • 7.086
  • 0.001318
  • 0.4428
  • 0.1762
  • 0.7965
  • -18.1
Output
  • 0.007236
  • 0.0009925
  • 0.00000773
  • 0.00006203
  • 0
  • 0.00001859
  • 0.00006892
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.7666
  • 0
  • 0.0005368
  • 0
  • 50.91
  • 0.0002007
  • -0.008797
Output
  • 0.2486
  • 0
  • 0.000001664
  • 0
  • 1.598
  • 0.000004925
  • -0.001061
Output
  • 0.1477
  • 0
  • 0.000005706
  • 0
  • 2.511
  • 0.0003148
  • -0.006678
Output
  • 2.235
  • 0
  • 0.00008633
  • 0
  • 37.98
  • 0.004763
  • -0.101

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2716
  • 145.7
  • 1.113
  • 9.106
  • 2.327
  • -44.52
  • -378.1
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.02486
  • 0.0002662
  • 1.241E-7
  • 0.00001664
  • 0.000002166
  • -0.00009314
  • -0.005926
Acidification potential, Accumulated Exceedance (AP)
  • 1.328
  • 0.02769
  • 0.0008461
  • 0.001731
  • 0.00141
  • -0.02653
  • -0.2979
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.8728
  • 0.003988
  • 0.00001516
  • 0.0002493
  • 0.001123
  • -0.002925
  • -0.0292
Global Warming Potential - fossil fuels (GWP-fossil)
  • 215.1
  • 9.636
  • 0.08088
  • 0.6022
  • 6.556
  • -5.11
  • -44.45
Global Warming Potential - total (GWP-total)
  • 216.2
  • 9.643
  • 0.0809
  • 0.6027
  • 6.558
  • -5.115
  • -44.5
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.1594
  • 0.00343
  • 0.000006375
  • 0.0002144
  • 0.0001412
  • -0.00209
  • -0.0284
  • 216.1
  • 9.643
  • 0.0809
  • 0.6027
  • 6.557
  • -7.808
  • -66.05
Eutrophication potential - freshwater (EP-freshwater)
  • 0.01328
  • 0.00007698
  • 2.944E-7
  • 0.000004812
  • 0.00001117
  • -0.0003316
  • -0.003335
Eutrophication potential - marine (EP-marine)
  • 0.2173
  • 0.00548
  • 0.0003735
  • 0.0003425
  • 0.0004706
  • -0.005193
  • -0.04922
Eutrophication potential - terrestrial (EP-terrestrial)
  • 2.672
  • 0.06129
  • 0.004098
  • 0.003831
  • 0.005068
  • -0.05566
  • -0.5218
Photochemical Ozone Creation Potential (POCP)
  • 0.9904
  • 0.02348
  • 0.001127
  • 0.001467
  • 0.00128
  • -0.02666
  • -0.2348
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00002458
  • 0.000002183
  • 1.748E-8
  • 1.364E-7
  • 6.283E-8
  • -1.605E-7
  • -0.01605
Water (user) deprivation potential (WDP)
  • 6532
  • 140.9
  • 0.2365
  • 8.808
  • 9.79
  • 288.2
  • 2202

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 7.36
  • 0.6368
  • 0.00477
  • 0.0398
  • 0.009646
  • 0.02356
  • 0.09411
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001677
  • 5.899E-7
  • 2.239E-8
  • 3.687E-8
  • 1.27E-8
  • -4.425E-7
  • -0.000003885
Potential Soil quality index (SQP) 2
  • 2434
  • 101.9
  • 0.1413
  • 6.369
  • 0.7782
  • 0.245
  • -57.77
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000009521
  • 1.18E-7
  • 5.52E-10
  • 7.374E-9
  • 9.41E-9
  • 6.402E-7
  • 0.00000358
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.000001642
  • 0
  • 0
  • 0
  • 6.12E-10
  • -2.485E-8
  • -2.206E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1.094E+4
  • 108
  • 0.6084
  • 6.75
  • 18.01
  • -3E+2
  • -3212