| Key Data Set Information | |
| Location | DE |
| Geographical representativeness description | Europe. |
| Reference year | 2024 |
| Name |
|
| Technical purpose of product or process | Splitter with high insertion loss and broadband attenuation even in the low frequency range. Sound attenuator splitters with resonating panels, ready to be used in ventilation and air conditioning systems. For more information see: https://www.trox.de/en/splitters/mk-1349ac4f5547bf7f Sound attenuator splitters used for the reduction of fan noise and air-regenerated noise in air conditioning systems. Attenuation effect due to absorption and resonance. Energy-saving as well as hygiene tested.Installation kit consists of an aerodynamically profiled frame (bullnose radius of 20 mm), sound absorbing material and resonating panels. The splitter frame reduces pressure losses and air-regenerated noise. The special profile helps to reduce the weight and increase the rigidity of the splitters. Frame edges with bullnose to protect the sound absorbing infill. Insertion loss and sound power level of the air-regenerated noise tested to ISO 7235. Meets the hygiene requirements of VDI 6022, VDI 3803 Part 1 and DIN 1946 Part 4. For use in areas with potentially explosive atmospheres (ATEX), zones 1, 2, 21 and 22 (outside) according to Directive 1999/92/ EC. This EPD includes the environmental data of the product series MK 100. The following represents a specific dataset of the most sold variant in the declared sales year (MK-F/100x1220x918). |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | 2024-08-15 - 2029-08-15 |
| Technological representativeness | |
| Technology description including background system | Splitter thickness: 100, 200, 230 mm. Nominal sizes (H × L): 150 × 450 – 1500 × 2500 mm, 450 × 150 – 2500 × 1500 mm. Height subdivide: 2501 – 5000 mm or if H and L > 1500 mm. Length subdivided: 2501 – 5000 mm or if H and L > 1500 mm. Intermediate sizes In increments of 1 mm. Operating temperature: Up to 100 °C, variant L up to 300 °C for 8 h max. The length (L) of sound attenuator splitters refers to the airflow direction. For more technical information see: https://www.trox.de/en/splitters/mk-1349ac4f5547bf7f#technical-information. |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-03-10T15:50:01 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | f0730941-53b0-4df4-9212-c7e9318cac56 |
| Date of last revision | 2024-10-11T06:01:41.0528508Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-7237-6642 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle