Close Go back Collapse all sections
Process Data set: Pelare Uddevalla Biobetong 2 (en) en

Key Data Set Information
Location SE
Geographical representativeness description Sweden
Reference year 2024
Name
Pelare Uddevalla Biobetong 2
Technical purpose of product or process A precast concrete column element is a robust pillar designed for structural support in construction. It offers load-bearing capabilities, architectural versatility, and is engineered for easy installation and long-term durability, making it a fundamental component in modern building frameworks.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Concrete goods
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-06-07" - "2029-06-07"
Technological representativeness
Technology description including background system Declared unit is 1 tonne concrete column with concrete quality C45/55, w/c ratio 0.45, and contains an average reinforcement amount of 32,9kg/ton and an average amount of cast-in materials of 2,47kg/ton. The declared unit applies to a wide range of dimensions with average amounts of reinforcement and cast-in materials. Cement is Heidelberg Materials Bascement CEM II 42.5 R. See EPD-HCG-20210157-CAA1-EN Concrete strength C45/55. Exposure classes up to XC4-XS2-XD2-XF3. Life length class up to L100 (100 years). More technical data and information on load capacity for different dimensions is available at Heidelberg Materials Precast Contiga's concrete factory in Uddevalla.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 153.7
  • 0.5442
  • 71.74
  • 1.513
  • 0.2289
  • 0.5289
  • 1.513
  • 7.445
  • 0.6812
  • -14.56
Input
  • 0.275
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 154
  • 0.5442
  • 71.74
  • 1.513
  • 0.2289
  • 0.5289
  • 1.513
  • 7.445
  • 0.6812
  • -14.56
Input
  • 1262
  • 43.76
  • 19.16
  • 120.3
  • 42.32
  • 97.39
  • 120.3
  • 14.47
  • 44.27
  • -132.9
Input
  • 14.78
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1277
  • 43.76
  • 19.16
  • 120.3
  • 42.32
  • 97.39
  • 120.3
  • 14.47
  • 44.27
  • -132.9
Input
  • 64.66
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 93.62
  • 0.01897
  • 0.06163
  • 0.05291
  • 0.005632
  • 0.005632
  • 0.05291
  • 0
  • 0.01408
  • 0.3336
Input
  • 207.1
  • 0.06307
  • 0.1705
  • 0.1773
  • 0.08287
  • 0.08287
  • 0.1773
  • 0
  • 0.04047
  • 13.13
Input
  • 1.141
  • 0.004914
  • 0.5829
  • 0.01368
  • 0.002178
  • 0.005013
  • 0.01368
  • 0.02478
  • 0.05273
  • -0.9598
Output
  • 0.3596
  • 0.00238
  • 0.01243
  • 0.00658
  • 0.001246
  • 0.002867
  • 0.00658
  • 0.001445
  • 0
  • -0.07165
Output
  • 629.2
  • 3.719
  • 6.377
  • 10.45
  • 0.05011
  • 0.1153
  • 10.45
  • 0.04565
  • 320.4
  • -5.339
Output
  • 0.007609
  • 0.0002989
  • 0.0001349
  • 0.0008211
  • 0.0002939
  • 0.0006763
  • 0.0008211
  • 0.000153
  • 0
  • -0.0001667
Output
  • 0.001353
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 5.978
  • 0
  • 0
  • 0
  • 0
  • 679.6
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01049
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.005677
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.08588
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 1175
  • 43.75
  • 19.16
  • 120.3
  • 42.32
  • 97.39
  • 120.3
  • 14.46
  • 44.26
  • -131.5
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001647
  • 0.00004743
  • 0.00003433
  • 0.0001319
  • 0.000004719
  • 0.00001086
  • 0.0001319
  • 0.000005911
  • 0.00001214
  • -0.0003509
Acidification potential, Accumulated Exceedance (AP)
  • 0.5735
  • 0.01101
  • 0.01276
  • 0.02384
  • 0.03217
  • 0.07403
  • 0.02384
  • 0.00377
  • 0.01339
  • -0.07618
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.176
  • 0.001148
  • 0.01267
  • 0.003171
  • 0.0005765
  • 0.001327
  • 0.003171
  • 0.004024
  • 0.001167
  • -0.03692
Global Warming Potential - fossil fuels (GWP-fossil)
  • 181.3
  • 2.71
  • 1.389
  • 7.403
  • 3.075
  • 7.075
  • 7.403
  • 0.4657
  • 1.372
  • -14.11
Global Warming Potential - total (GWP-total)
  • 181.6
  • 2.712
  • 1.404
  • 7.409
  • 3.076
  • 7.076
  • 7.409
  • 0.4723
  • 1.373
  • -14.15
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.1529
  • 0.0008503
  • 0.001813
  • 0.002256
  • 0.0002424
  • 0.0005577
  • 0.002256
  • 0.0006445
  • 0.000269
  • -0.006664
  • 181.4
  • 2.712
  • 1.401
  • 7.408
  • 3.076
  • 7.076
  • 7.408
  • 0.4664
  • 1.373
  • -20.49
Eutrophication potential - freshwater (EP-freshwater)
  • 0.01078
  • 0.00002124
  • 0.00003454
  • 0.0000589
  • 0.00001119
  • 0.00002576
  • 0.0000589
  • 0.00002943
  • 0.00001024
  • -0.0008158
Eutrophication potential - marine (EP-marine)
  • 0.0889
  • 0.002488
  • 0.004503
  • 0.00522
  • 0.0142
  • 0.03268
  • 0.00522
  • 0.001105
  • 0.00502
  • -0.01765
Eutrophication potential - terrestrial (EP-terrestrial)
  • 1.483
  • 0.02773
  • 0.05013
  • 0.05822
  • 0.1558
  • 0.3558
  • 0.05822
  • 0.01273
  • 0.05531
  • -0.1876
Photochemical Ozone Creation Potential (POCP)
  • 0.548
  • 0.009947
  • 0.0138
  • 0.02286
  • 0.04283
  • 0.09858
  • 0.02286
  • 0.003408
  • 0.01582
  • -0.07771
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00000611
  • 6.503E-7
  • 2.381E-7
  • 0.000001785
  • 6.641E-7
  • 0.000001528
  • 0.000001785
  • 9.184E-8
  • 6.679E-7
  • -6.735E-7
Water (user) deprivation potential (WDP)
  • 2905
  • 32.98
  • 972.7
  • 92.2
  • 8.992
  • 20.69
  • 92.2
  • 1596
  • 93.18
  • -537.6

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 6025
  • 0.1912
  • 0.1595
  • 0.5256
  • 0.1814
  • 0.4214
  • 0.5256
  • 0.2427
  • 0.1921
  • -0.1879
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000009157
  • 2.439E-7
  • 2.713E-7
  • 6.8E-7
  • 8.509E-7
  • 0.000005917
  • 6.8E-7
  • 6.035E-8
  • 2.851E-7
  • -0.000001334
Potential Soil quality index (SQP) 2
  • 435.5
  • 49.15
  • 5.337
  • 137.8
  • 5.371
  • 12.06
  • 137.8
  • 8.18
  • 161.4
  • 49.73
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000005544
  • 3.093E-8
  • 3.656E-8
  • 8.5E-8
  • 2.126E-8
  • 4.926E-8
  • 8.5E-8
  • 9.183E-9
  • 1.281E-8
  • 0.000001286
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 7.447E-7
  • 0
  • 1.551E-9
  • 0
  • 8.98E-10
  • 1.898E-9
  • 0
  • 6.56E-10
  • 6.4E-10
  • -6.196E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2706
  • 31.83
  • 33.23
  • 87.92
  • 23.13
  • 53.23
  • 87.92
  • 10.25
  • 21.9
  • -728.9