Close Go back Collapse all sections
Process Data set: ÖLFLEX® CLASSIC 110 4G2,5 (en) en

Key Data Set Information
Location FR
Geographical representativeness description Norway
Reference year 2025
Name
ÖLFLEX® CLASSIC 110 4G2,5
Technical purpose of product or process ÖLFLEX CLASSIC 110 cables are VDE approved control cables for occasional flexible use and fixed installation for medium mechanical load conditions. They are also suitable for use in dry, damp or wet areas. If using outdoors, observe the indicated temperature range and use with UV protection. They are largely resistant to acids, alkalis and certain oils at room temperature. ÖLFLEX CLASSIC 110 cables are limited suitable for free and continuously recurring movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. Application range: As connecting cable for control systems in machine tools, plant engineering and construction, industrial machinery, conveyor systems, production and assembly lines as well as in measuring and control technology and data processing systems. This cable is suitable for torsion application in wind turbines. The torsional load is limited to applications, which are typical for the loop in wind turbine generators (WTG). Design Design based on EN 50525-2-51 Certification VDE-REG 7030 limited to following dimension range: 0.5 mm² - 2.5 mm² 2 - 65 cores 4 mm² - 16 mm² 2 - 7 cores 25 mm² - 120 mm² 2 - 5 cores EN 13501-6 and EN 50575 Classification of fire behaviour (article/dimension range see www.lappkabel.com/cpr) Conductor Fine wire strands of bare copper, acc. to IEC 60228 resp. EN IEC 60228, Class 5 Insulation PVC compound TI2 acc. to EN 50363-3 with increased requirements acc. to Lapp specification Core identification code acc. to VDE 0293-1, with or without GN/YE ground conductor black cores with white numbers acc. to EN 50334 Cable assembly Cores are stranded in layers Outer sheath PVC compound TM2 acc. to EN 50363-4-1 with increased requirements acc. to LAPP specification colour: Silver Grey, similar RAL 7001
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.002067083335 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-07-28 - 2030-07-28
Technological representativeness
Technology description including background system Electrical properties at 20 °C Nominal voltage U0 /U: 300/500V Test voltage core / core: 4000 V AC Mechanical and thermal properties Minimum bending radius Occasional flexing: 10 x outer diameter Fixed installation: 4 x outer diameter Temperature range Occasional flexing: - 15°C up to +70°C max. conductor temp. Fixed installation: - 40°C up to +80°C max. conductor temp. Bending cycles and power chain Power Chain Operation parameters Limited to 2-7 cores and 0.5 – 2.5 mm² Min. bending radius: 15 x outer diameter temperature range: -5 °C up to +70 °C max. conductor temp. Travelling distance up to 5 m: 0.2 … 1 million bending cycles Torsional stress in WTG: TW-0 (5000 cycles at = +5°C) TW-1 (2000 cycles at = -20°C) ± 150°/m at 1 revolution per minute Flammability Flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 Oil resistance acc. to EN 50290-2-22 TM54 Tests acc. to IEC 60811 resp. EN 60811, EN 50395, EN 50396 General requirements These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive). A part of these cables (see www.lappkabel.com/cpr) are classified in accordance with the EU-Regulation no. 305/2011 (CPR). Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS).

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.576
  • 0.004108
  • 0.2514
  • 0.006544
  • 0.05405
  • 0
  • 0.0004898
  • 0.01127
  • 0.002946
  • -0.7624
Input
  • 0.0694
  • 0
  • 0
  • 0
  • -0.06593
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.646
  • 0.004108
  • 0.2514
  • 0.006544
  • -0.01188
  • 0
  • 0.0004898
  • 0.01127
  • 0.002946
  • -0.7624
Input
  • 7.961
  • 0.287
  • 1.654
  • 0.5203
  • 0.3234
  • 0
  • 0.03422
  • 0.08832
  • 0.03063
  • -1.22
Input
  • 1.441
  • 0
  • 0
  • 0
  • 0.02394
  • 0
  • 0
  • -1.893
  • 0
  • 0
Input
  • 9.402
  • 0.287
  • 1.654
  • 0.5203
  • 0.3473
  • 0
  • 0.03422
  • -1.805
  • 0.03063
  • -1.22
Input
  • 0.0164
  • 0
  • 0
  • 0
  • 0.0004276
  • 0
  • 0
  • 0
  • 0.000001153
  • 0.03841
Input
  • 0.04065
  • 0.000147
  • 0.001814
  • 0.0002289
  • 0.00113
  • 0
  • 0.00001752
  • 0.0002038
  • 0.00006377
  • 0.003601
Input
  • 0.001315
  • 0.0005255
  • 0.004628
  • 0.0007672
  • 0.0003194
  • 0
  • 0.00006266
  • 0
  • 0.0001301
  • -0.009439
Input
  • 0.0105
  • 0.00003069
  • 0.001526
  • 0.0000592
  • 0.0003896
  • 0
  • 0.000003659
  • 0.002113
  • 0.00003653
  • -0.003563
Output
  • 0.005963
  • 0.0000148
  • 0.003326
  • 0.00002846
  • 0.0003734
  • 0
  • 0.000001765
  • 0
  • 0.001921
  • -0.001489
Output
  • 0.213
  • 0.01396
  • 0.01596
  • 0.04522
  • 0.01467
  • 0
  • 0.001664
  • 0
  • 0.08786
  • -0.06438
Output
  • 0.00003091
  • 0.000001955
  • 0.00002099
  • 0.000003552
  • 0.000002021
  • 0
  • 2.331E-7
  • 0
  • 1.737E-7
  • -0.000001566
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01209
  • 0
  • 0.002015
  • 0
  • 0
  • 0.0576
  • 0.000003947
  • -0.001503
Output
  • 0
  • 0
  • 0.01426
  • 0
  • 0.005672
  • 0
  • 0
  • 0.0335
  • 9.653E-8
  • -0.0001979
Output
  • 0
  • 0
  • 0.00873
  • 0
  • 0.004423
  • 0
  • 0
  • 0.03427
  • 0.000006262
  • -0.0004849
Output
  • 0
  • 0
  • 0.1321
  • 0
  • 0.06692
  • 0
  • 0
  • 0.5185
  • 0.00009474
  • -0.007337

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 9.398
  • 0.287
  • 1.654
  • 0.5203
  • 0.3698
  • 0
  • 0.03422
  • 0.0883
  • 0.03063
  • -1.22
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0002077
  • 5.243E-7
  • 3.713E-7
  • 5.707E-7
  • 0.000005172
  • 0
  • 6.251E-8
  • 1.414E-7
  • 1.15E-8
  • -0.0001235
Acidification potential, Accumulated Exceedance (AP)
  • 0.02289
  • 0.00005455
  • 0.00008092
  • 0.0001031
  • 0.0005775
  • 0
  • 0.000006504
  • 0.00003882
  • 0.00001119
  • -0.02207
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.002495
  • 0.000007856
  • 0.001574
  • 0.00001372
  • 0.007532
  • 0
  • 9.367E-7
  • 0.00002734
  • 0.00000106
  • -0.0006171
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.6013
  • 0.01898
  • 0.02351
  • 0.03203
  • 0.0201
  • 0
  • 0.002263
  • 0.06712
  • 0.006843
  • -0.1346
Global Warming Potential - total (GWP-total)
  • 0.6044
  • 0.019
  • 0.0251
  • 0.03205
  • 0.02765
  • 0
  • 0.002265
  • 0.06715
  • 0.006844
  • -0.1354
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0006029
  • 0.000006756
  • 0.00001437
  • 0.000009758
  • 0.00001726
  • 0
  • 8.055E-7
  • 0.000005244
  • 4.672E-7
  • -0.0002525
  • 0.6113
  • 0.01899
  • 0.02478
  • 0.03205
  • 0.02036
  • 0
  • 0.002265
  • 0.06732
  • 0.005704
  • -0.06566
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001864
  • 1.516E-7
  • 5.799E-7
  • 2.548E-7
  • 0.000004661
  • 0
  • 1.808E-8
  • 1.976E-7
  • 3.257E-8
  • -0.0001488
Eutrophication potential - marine (EP-marine)
  • 0.001589
  • 0.00001079
  • 0.00001773
  • 0.00002258
  • 0.00004274
  • 0
  • 0.000001287
  • 0.000009475
  • 0.00000899
  • -0.0009142
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.023
  • 0.0001207
  • 0.0001678
  • 0.0002519
  • 0.0006032
  • 0
  • 0.0000144
  • 0.0001016
  • 0.00004255
  • -0.01414
Photochemical Ozone Creation Potential (POCP)
  • 0.005828
  • 0.00004625
  • 0.0000467
  • 0.00009891
  • 0.0001556
  • 0
  • 0.000005514
  • 0.00002875
  • 0.00001296
  • -0.00384
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.146E-7
  • 4.3E-9
  • 7.578E-9
  • 7.722E-9
  • 4.224E-9
  • 0
  • 5.13E-10
  • 2.206E-9
  • 3.74E-10
  • -0.000241
Water (user) deprivation potential (WDP)
  • 35.19
  • 0.2776
  • 25.02
  • 0.3989
  • 2.202
  • 0
  • 0.0331
  • 1.803
  • 0.5473
  • 6.597

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.03373
  • 0.001254
  • 0.01631
  • 0.002274
  • 0.001805
  • 0
  • 0.0001496
  • 0.0004291
  • 0.0001756
  • -0.001759
Potential incidence of disease due to PM emissions (PM) 2
  • 6.595E-8
  • 1.162E-9
  • 4.91E-10
  • 2.942E-9
  • 1.838E-9
  • 0
  • 1.39E-10
  • 2.52E-10
  • 1.74E-10
  • -4.572E-8
Potential Soil quality index (SQP) 2
  • 6.325
  • 0.2007
  • 0.09679
  • 0.5964
  • 0.2101
  • 0
  • 0.02393
  • 0.03216
  • 0.08573
  • -2.889
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.7E-7
  • 2.32E-10
  • 4.46E-10
  • 3.68E-10
  • 9.144E-9
  • 0
  • 2.8E-11
  • 9.97E-10
  • 7.1E-11
  • -2.455E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.918E-9
  • 0
  • 1.8E-11
  • 0
  • 1.22E-10
  • 0
  • 0
  • 9E-12
  • 2E-12
  • -2.866E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 272.6
  • 0.2127
  • 0.594
  • 0.3804
  • 7.397
  • 0
  • 0.02537
  • 4.232
  • 23.81
  • -203