Close Go back Collapse all sections
Process Data set: 4X240 PEX-M-AL 1KV DGREY (en) en

A more recent version of this data set exists in the database.

Most recent version of this data set:00.04.000

Key Data Set Information
Location DK
Geographical representativeness description Denmark
Reference year 2023
Name
4X240 PEX-M-AL 1KV DGREY
Technical purpose of product or process For fixed installation, indoors and outdoors, in the ground, in concrete and in water. Installation of the product should only be carried out by personnel trained and qualified for electrical works. The product is designed according to recognized standards. Applicable rules of installation must be applied at all times. 1. Aluminium conductor 2. XLPE insulation 3. Bedding 4. PE sheath
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electrical cables and wires
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2028
Time representativeness description "2023-12-25" - "2028-12-25"
Technological representativeness
Technology description including background system Norm (standard): HD 603-5B Rated voltage Uo/U: 0,6/1 kV Test voltage: 4 (AC) kV Maximal short-circuit temperature: 250 °C Maximal operating conductor temperature: 90 °C Temperature range: from -35 up to +90 °C Minimal temperature for laying and manipulation: -15 °C Minimal storage temperature: -35 °C Self-extinguishing of one cable: no CPR-Classification (reaction on fire): Fca UV stability: Yes Max. permitted pulling force: 30 N/mm2 Minimal radius of bend: 10 * D mm RoHS: Yes REACH: Yes CE Conformity: Yes LVD Conformity: Yes

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 125.6
  • 0.0348
  • 9.311
  • 0.02363
  • 2.706
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6521
  • 0
  • 0
  • 0.03545
  • 0.002526
  • 0.03942
  • -62.84
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 125.6
  • 0.0348
  • 9.311
  • 0.02363
  • 2.706
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6521
  • 0
  • 0
  • 0.03545
  • 0.002526
  • 0.03942
  • -62.84
Input
  • 454.8
  • 3.463
  • 4.955
  • 1.651
  • 9.568
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.7595
  • 0
  • 0
  • 2.477
  • 0.08594
  • 0.3532
  • -156.5
Input
  • 38.84
  • 0
  • 0
  • 0
  • 0.03711
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -36.99
  • 0
  • 0
Input
  • 493.7
  • 3.463
  • 4.955
  • 1.651
  • 9.605
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.7595
  • 0
  • 0
  • 2.477
  • -36.91
  • 0.3532
  • -156.5
Input
  • 0.3756
  • 0
  • 0
  • 0
  • 0.007587
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003749
  • 0
Input
  • 0.6424
  • 0.001111
  • 0.001445
  • 0.0008455
  • 0.013
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02452
  • 0
  • 0
  • 0.001268
  • 0.00007119
  • 0.0008191
  • -0.02413
Input
  • 0.1217
  • 0.003917
  • 0.01183
  • 0.003023
  • 0.002941
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001298
  • 0
  • 0
  • 0.004535
  • 0
  • 0.001718
  • -0.305
Input
  • 0.7393
  • 0.0002624
  • 0.003652
  • 0.0001766
  • 0.01489
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00242
  • 0
  • 0
  • 0.0002648
  • 0.0002427
  • 0.0004536
  • -0.3153
Output
  • 0.2863
  • 0.0001593
  • 0.01228
  • 0.00008515
  • 0.006804
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001004
  • 0
  • 0
  • 0.0001277
  • 0
  • 0.04078
  • 0.05149
Output
  • 8.799
  • 0.0807
  • 0.03104
  • 0.08029
  • 0.2065
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004635
  • 0
  • 0
  • 0.1204
  • 0
  • 1.195
  • -3.578
Output
  • 0.00172
  • 0.00002388
  • 0.000005592
  • 0.00001125
  • 0.00003647
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000002392
  • 0
  • 0
  • 0.00001687
  • 0
  • 0.000002421
  • -0.0006411
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.0001372
  • 0
  • 0.03461
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.73
  • 0.00004597
  • 0
Output
  • 0
  • 0
  • 0.05239
  • 0
  • 0.008739
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4355
  • 0.0000946
  • 0
Output
  • 0
  • 0
  • 0.03104
  • 0
  • 0.01759
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.8445
  • 0.0008934
  • 0
Output
  • 0
  • 0
  • 0.4696
  • 0
  • 0.2662
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 12.78
  • 0.01352
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 492
  • 3.463
  • 4.955
  • 1.651
  • 10.31
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.7593
  • 0
  • 0
  • 2.476
  • 0.08593
  • 0.3532
  • -156.5
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0008116
  • 0.000003917
  • 0.00000728
  • 0.000003016
  • 0.00001668
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.216E-7
  • 0
  • 0
  • 0.000004524
  • 4.598E-8
  • 1.186E-7
  • 0.00001805
Acidification potential, Accumulated Exceedance (AP)
  • 0.2487
  • 0.005041
  • 0.0006827
  • 0.0003138
  • 0.00541
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002349
  • 0
  • 0
  • 0.0004707
  • 0.0001645
  • 0.0001193
  • -0.0834
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.3301
  • 0.00008244
  • 0.006137
  • 0.00004519
  • 0.006736
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000607
  • 0
  • 0
  • 0.00006779
  • 0.00001062
  • 0.000004881
  • -0.05634
Global Warming Potential - fossil fuels (GWP-fossil)
  • 36.45
  • 0.2519
  • 0.3484
  • 0.1092
  • 0.7891
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05857
  • 0
  • 0
  • 0.1638
  • 1.314
  • 0.06123
  • -12.3
Global Warming Potential - total (GWP-total)
  • 37.25
  • 0.2521
  • 0.3546
  • 0.1093
  • 0.8053
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05925
  • 0
  • 0
  • 0.1639
  • 1.314
  • 0.06124
  • -12.59
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.4705
  • 0.000134
  • 0.00004235
  • 0.00003886
  • 0.009422
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00007886
  • 0
  • 0
  • 0.00005829
  • 0.00000156
  • 0.000005242
  • -0.2348
  • 37.18
  • 0.2521
  • 0.3483
  • 0.1093
  • 0.8036
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.08194
  • 0
  • 0
  • 0.1639
  • 1.314
  • 0.06341
  • -12.02
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001564
  • 0.000001415
  • 0.000002397
  • 8.723E-7
  • 0.00003146
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000004794
  • 0
  • 0
  • 0.000001309
  • 1.007E-7
  • 2.492E-7
  • -0.0004793
Eutrophication potential - marine (EP-marine)
  • 0.03266
  • 0.001225
  • 0.0002062
  • 0.00006209
  • 0.000764
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000395
  • 0
  • 0
  • 0.00009314
  • 0.00007897
  • 0.00009433
  • -0.01064
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.3608
  • 0.01362
  • 0.00211
  • 0.0006945
  • 0.008432
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005639
  • 0
  • 0
  • 0.001042
  • 0.0008542
  • 0.0004781
  • -0.1171
Photochemical Ozone Creation Potential (POCP)
  • 0.1172
  • 0.003615
  • 0.0006593
  • 0.000266
  • 0.002669
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001202
  • 0
  • 0
  • 0.0003991
  • 0.0002045
  • 0.000146
  • -0.03936
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000002805
  • 5.533E-8
  • 4.382E-8
  • 2.473E-8
  • 6.202E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.992E-9
  • 0
  • 0
  • 3.71E-8
  • 1.007E-9
  • 4.425E-9
  • -0.005397
Water (user) deprivation potential (WDP)
  • 1.453E+4
  • 1.893
  • 1.571
  • 1.597
  • 290.9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 11.8
  • 0
  • 0
  • 2.395
  • 0.1946
  • 7.287
  • -7.02E+3

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.814
  • 0.01499
  • 0.004053
  • 0.007216
  • 0.0376
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003713
  • 0
  • 0
  • 0.01082
  • 0.0001453
  • 0.002166
  • -0.6831
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000002346
  • 9.506E-9
  • 8.641E-9
  • 6.685E-9
  • 4.797E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.151E-9
  • 0
  • 0
  • 1.003E-8
  • 6.44E-10
  • 2.146E-9
  • -8.91E-7
Potential Soil quality index (SQP) 2
  • 74.17
  • 1.343
  • 0.2704
  • 1.155
  • 1.606
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.248
  • 0
  • 0
  • 1.732
  • 0.01043
  • 0.8251
  • -8.411
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001156
  • 2.319E-9
  • 3.159E-9
  • 1.337E-9
  • 2.342E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.84E-10
  • 0
  • 0
  • 2.005E-9
  • 1.101E-9
  • 4.73E-10
  • -3.661E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 7.427E-8
  • 0
  • 2.41E-10
  • 0
  • 1.492E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.7E-11
  • 0
  • 0
  • 0
  • 2.9E-11
  • 2.3E-11
  • -3.106E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 826.1
  • 2.253
  • 2.049
  • 1.224
  • 25.93
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.351
  • 0
  • 0
  • 1.836
  • 0.2566
  • 459.1
  • -190.3