Close Go back Collapse all sections
Process Data set: Protecta FR Putty (en) en

Key Data Set Information
Location GB
Geographical representativeness description Global. Transport to market is not included in this EPD.
Reference year 2024
Name
Protecta FR Putty
Use advice for data set The life cycle analysis is a cradle-to-gate (A1 - A3) study. It includes the extraction and production of raw materials and packaging, transportation to the manufacturing site, as well as the manufacturing process itself. A1: Wooden pallets and the wrapping around the pallets are excluded on the basis that the product is shipped in boxes.
Technical purpose of product or process Protecta FR Putty is an easy-to-apply fire and sound-rated sealant supplied as a non-setting putty. The putty is hand-workable, re-useable and re-serviceable due to its non-setting properties. The putty is manufactured and supplied in different shapes and forms for different applications. Putty Pads for sockets When electrical sockets and switches are installed in dry-lining partitions, the original fire rating of the partition is compromised. Fitting Putty Pads will reinstate the fire rating of the partition for up to two hours (depending on the partition fire rating) preventing the passage of smoke and flames in a fire, and sound and air movement during service life, through the electrical socket, into the cavity. Putty Cords for fire sealing services The putty cord is designed to be easily fitted around service penetrations where the gap around the services is very small, or there are no gaps at all so a conventional fire-rated sealant is impossible or difficult to fit due to the required depth and backing material. The putty cords are fitted to cover the gap around the services and do not need to fill the gap to the required depth. Putty Pads for water supply boxes When tap water wall boxes are installed in dry-lining partitions, the original fire rating of the partition is compromised. Fitting Putty Pads will reinstate the fire rating of the partition preventing the passage of smoke and flames in a fire, and sound and air movement during service life, through the tap water wall boxes, into the cavity.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Technical-chemical building materials products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-09-24" - "2029-09-24"
Technological representativeness
Technology description including background system The product has third-party verified ETAs and UKTAs issued in accordance with regulation (EU) No 305/2011 on the basis of EAD 350454-00-1104. The product holds the following approval marks; CE-mark for Europe, UKCA-mark for UK, UL-EU Certificate Internationally, UAE Certificate of Compliance & AS assessment for Australia and New Zealand. For more information, please see https://protecta.co.uk/product/fire-rated-putty-pad-for-electrical-sockets/, https://protecta.co.uk/product/fire-rated-putty-pad-tap-water/ and https://protecta.co.uk/product/fire-rated-putty-cord/

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Input
  • 13.02
  • 0.02321
  • 0.2939
  • 0.03136
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 13.02
  • 0.02321
  • 0.2939
  • 0.03136
Input
  • 89.02
  • 1.673
  • 1.067
  • 3.183
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 89.02
  • 1.673
  • 1.067
  • 3.183
Input
  • 0.02036
  • 0
  • 0
  • 0
Input
  • 0.1245
  • 0.0009351
  • 0.0004263
  • 0.001004
Input
  • 0.01678
  • 0.002828
  • 0.0004959
  • 0.002586
Input
  • 0.05527
  • 0.0001986
  • 0.0004301
  • 0.0002361
Output
  • 0.02329
  • 0.00009227
  • 0.00321
  • 0.0001444
Output
  • 3.526
  • 0.1226
  • 0.006311
  • 0.07245
Output
  • 0.0001757
  • 0.00001141
  • 0.000008584
  • 0.00002197
Output
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0003075
  • 0
  • 0.0108
  • 0
Output
  • 0.00004023
  • 0
  • 0.01415
  • 0
Output
  • 0.00003813
  • 0
  • 0.00841
  • 0
Output
  • 0.0005769
  • 0
  • 0.1272
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Abiotic depletion potential - fossil resources (ADPF)
  • 88.88
  • 1.673
  • 1.067
  • 3.182
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00007169
  • 0.000001802
  • 6.494E-7
  • 0.000003509
Acidification potential, Accumulated Exceedance (AP)
  • 0.04433
  • 0.0005532
  • 0.0001831
  • 0.004804
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.002828
  • 0.00005006
  • 0.001684
  • 0.00007445
Global Warming Potential - fossil fuels (GWP-fossil)
  • 7.579
  • 0.1071
  • 0.0523
  • 0.2318
Global Warming Potential - total (GWP-total)
  • 7.588
  • 0.1072
  • 0.05405
  • 0.232
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.006321
  • 0.00005544
  • 0.0000597
  • 0.0001194
  • 7.586
  • 0.1072
  • 0.06291
  • 0.232
Eutrophication potential - freshwater (EP-freshwater)
  • 0.000219
  • 8.989E-7
  • 0.000001339
  • 0.000001276
Eutrophication potential - marine (EP-marine)
  • 0.00812
  • 0.0001536
  • 0.000037
  • 0.001185
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.09026
  • 0.001703
  • 0.0004028
  • 0.01317
Photochemical Ozone Creation Potential (POCP)
  • 0.02716
  • 0.0005325
  • 0.0001048
  • 0.003478
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.0005194
  • 2.46E-8
  • 4.667E-9
  • 4.888E-8
Water (user) deprivation potential (WDP)
  • 161.6
  • 1.425
  • 4.617
  • 1.709

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.2034
  • 0.007342
  • 0.0172
  • 0.01378
Potential incidence of disease due to PM emissions (PM) 2
  • 4.967E-7
  • 8.408E-9
  • 7.27E-10
  • 9.499E-9
Potential Soil quality index (SQP) 2
  • 53.71
  • 1.754
  • 0.8973
  • 1.211
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.662E-7
  • 1.068E-9
  • 6.56E-10
  • 2.404E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 7.032E-9
  • 0
  • 1.9E-11
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 377.3
  • 1.22
  • 0.772
  • 2.055