Close Go back Collapse all sections
Process Data set: K 100 M sileo (en) en

Key Data Set Information
Location SE
Geographical representativeness description Europe
Reference year 2025
Name
K 100 M sileo
Technical purpose of product or process The K fans are circular duct fans intended to use for supply or extract air, designed to be installed in any position, for a variety of commercial and domestic applications. K-fan range from size 100 to 315 with capacities from approximately 180 m³/h to 1,256 m³/h The EPD data is provided for size 100 (reference).
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-02-04 - 2030-02-04
Technological representativeness
Technology description including background system Airtight, seamed casing made from galvanized steel. Leakage rate compliant with tightness class C, according to EN 12237:2003. For more information see: https://www.systemair.com/en The composition of materials is the same for all sizes, and the ratio of materials is almost equal among the sizes. Key EPD data for the full range is provided in the following table, including suggested conversion factors. Size specific EPDs are also available upon request.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 18.76
  • 0.01495
  • 0.0002372
  • 0.002492
  • 0.008414
  • 0.001696
  • -4.219
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 18.76
  • 0.01495
  • 0.0002372
  • 0.002492
  • 0.008414
  • 0.001696
  • -4.219
Input
  • 148.4
  • 1.188
  • 0.04385
  • 0.1981
  • 0.03961
  • 0.05216
  • -20.63
Input
  • 4.443
  • 0
  • 0
  • 0
  • -4.443
  • 0
  • 0
Input
  • 152.8
  • 1.188
  • 0.04385
  • 0.1981
  • -4.403
  • 0.05216
  • -20.63
Input
  • 1.443
  • 0
  • 0.00002153
  • 0
  • 0.000009346
  • 8.377E-7
  • 0.03627
Input
  • 0.2179
  • 0.0005229
  • 0.000005834
  • 0.00008715
  • 0.0001851
  • 0.00003788
  • 0.05264
Input
  • 1.411
  • 0.001753
  • 0.00008585
  • 0.0002921
  • 0.00000244
  • 0.00005712
  • 1.477
Input
  • 0.1462
  • 0.0001352
  • 0.000002257
  • 0.00002254
  • 0.00008814
  • 0.00007981
  • -0.02138
Output
  • 0.1126
  • 0.00006502
  • 0.000001291
  • 0.00001084
  • 0.00004096
  • 0.0002802
  • -0.006067
Output
  • 3.99
  • 0.1033
  • 0.00005191
  • 0.01722
  • 0.005708
  • 0.292
  • -0.8077
Output
  • 0.0004172
  • 0.000008114
  • 3.045E-7
  • 0.000001352
  • 1.327E-7
  • 1.322E-7
  • -0.00002926
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.5543
  • 0
  • 0.00002114
  • 0
  • 2.067
  • 0.000006039
  • -0.001419
Output
  • 0.07142
  • 0
  • 6.555E-8
  • 0
  • 0.000001255
  • 1.525E-7
  • -0.0001869
Output
  • 0.03995
  • 0
  • 2.247E-7
  • 0
  • 0.006754
  • 0.000008468
  • -0.0004579
Output
  • 0.6044
  • 0
  • 0.0000034
  • 0
  • 0.1022
  • 0.0001281
  • -0.006927

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 152.8
  • 1.188
  • 0.04385
  • 0.1981
  • 0.03959
  • 0.05216
  • -20.63
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.006189
  • 0.000001304
  • 4.888E-9
  • 2.173E-7
  • 4.634E-8
  • 1.864E-8
  • -0.0001397
Acidification potential, Accumulated Exceedance (AP)
  • 0.1332
  • 0.0002356
  • 0.00003333
  • 0.00003926
  • 0.00002644
  • 0.00001705
  • -0.03189
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.04032
  • 0.00003134
  • 5.972E-7
  • 0.000005223
  • 0.0000101
  • 0.000003266
  • -0.004162
Global Warming Potential - fossil fuels (GWP-fossil)
  • 11.84
  • 0.07316
  • 0.003186
  • 0.01219
  • 0.1511
  • 0.008822
  • -2.131
Global Warming Potential - total (GWP-total)
  • 11.92
  • 0.07321
  • 0.003187
  • 0.0122
  • 0.1511
  • 0.008826
  • -2.147
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.04278
  • 0.00002229
  • 2.511E-7
  • 0.000003715
  • 0.000003221
  • 7.599E-7
  • -0.0124
  • 11.88
  • 0.07321
  • 0.003187
  • 0.0122
  • 0.1511
  • 0.008997
  • -2.745
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0009251
  • 5.821E-7
  • 1.16E-8
  • 9.702E-8
  • 1.283E-7
  • 2.811E-8
  • -0.0002498
Eutrophication potential - marine (EP-marine)
  • 0.01393
  • 0.00005159
  • 0.00001471
  • 0.000008598
  • 0.000009796
  • 0.00001304
  • -0.002812
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.3021
  • 0.0005754
  • 0.0001614
  • 0.00009589
  • 0.00009869
  • 0.00006684
  • -0.03367
Photochemical Ozone Creation Potential (POCP)
  • 0.05425
  • 0.0002259
  • 0.00004438
  • 0.00003766
  • 0.00002437
  • 0.00002049
  • -0.01253
Depletion potential of the stratospheric ozone layer (ODP)
  • 9.09E-7
  • 1.764E-8
  • 6.89E-10
  • 2.94E-9
  • 1.027E-9
  • 7.34E-10
  • -2.331E-7
Water (user) deprivation potential (WDP)
  • 1159
  • 0.9111
  • 0.009315
  • 0.1519
  • 1.333
  • 0.2355
  • -272.2

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.5579
  • 0.005194
  • 0.0001879
  • 0.0008656
  • 0.0002958
  • 0.0002357
  • -0.03028
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00002747
  • 6.72E-9
  • 8.82E-10
  • 1.12E-9
  • 1.63E-10
  • 3.25E-10
  • -2.001E-7
Potential Soil quality index (SQP) 2
  • 78.17
  • 1.362
  • 0.005564
  • 0.227
  • 0.01613
  • 0.1765
  • -3.374
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001166
  • 8.4E-10
  • 2.2E-11
  • 1.4E-10
  • 3.5E-10
  • 2.163E-8
  • -1.039E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.645E-8
  • 0
  • 0
  • 0
  • 1.2E-11
  • 3.15E-10
  • -1.096E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 843.6
  • 0.8689
  • 0.02396
  • 0.1448
  • 0.4077
  • 3.478
  • -278.4