Close Go back Collapse all sections
Process Data set: MS-100 (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe.
Reference year 2024
Name
MS-100
Technical purpose of product or process Splitter sound attenuator with high insertion loss, even in the low-frequency range. For more information see: https://www.trox.de/en/splitter-sound-attenuators/ms-7db0ac71f60e1f06. Splitter sound attenuators used for the reduction of fan noise and air-regenerated noise in ventilation and air conditioning systems. Attenuation effect due to absorption and resonance. Energy-saving as well as hygiene tested and certified. Splitter sound attenuator that consist of a duct with connections and integral type MK splitters or a splitter set. Splitters consist of an aerodynamically formed frame (bullnose radius 20 mm), sound absorbing material, and resonating panels. The splitter frame reduces pressure losses and air-regenerated noise. The profiled frame with bullnose edges increase the stiffness of the splitter. Insertion loss and sound power level of air-regenerated noise measured according to EN ISO 7235. For requirements in areas with potentially explosive atmospheres (ATEX), zones 1, 2, 21 and 22 (outside) according to Directive 1999/92/EC. The duct meets leakage class C and pressure class 2 according to EN 15727. This EPD includes the environmental data of the product series MS-100. The following represents a specific dataset of the most sold variant in the declared sales year (MS-F/500x250x1200/2x100/P).
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-09-04" - "2029-09-04"
Technological representativeness
Technology description including background system Splitter thickness: 100, 200, 230 mm. Nominal sizes (B × H × L): Type MS 100: 150 × 150 × 500 mm – 2400 × 1800 × 1500 mm. Type MS 200: 250 × 150 × 500 mm – 2400 × 1800 × 1500 mm. Type MS 230: 288 × 150 × 500 mm – 2400 × 1800 × 1500 mm. Width subdivided: 2401 – 4800 mm. Height subdivide: 1801 – 3600 mm. Length subdivided: 1501 – 3000 mm. Intermediate sizes: In increments of 1 mm. Operating temperature: Up to 100 °C, variant L up to 300 °C for 8 h max. The length (L) of splitter sound attenuators refers to the airflow direction. For more technical information see: https://www.trox.de/en/splitter-sound-attenuators/ms-7db0ac71f60e1f06#technical-information.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 278.3
  • 1.928
  • 0.006043
  • 0.1205
  • 0.00009571
  • 0.06101
  • -3.721
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 278.3
  • 1.928
  • 0.006043
  • 0.1205
  • 0.00009571
  • 0.06101
  • -3.721
Input
  • 1827
  • 134.7
  • 1.117
  • 8.417
  • 0.003256
  • 6.177
  • -42.83
Input
  • 1.402
  • 0
  • 0
  • 0
  • -1.402
  • 0
  • 0
Input
  • 1828
  • 134.7
  • 1.117
  • 8.417
  • -1.398
  • 6.177
  • -42.83
Input
  • 15.46
  • 0
  • 0.0005486
  • 0
  • 0
  • 0
  • 0
Input
  • 6.944
  • 0.06897
  • 0.0001487
  • 0.004311
  • 0.000002697
  • 0.001383
  • 0.1836
Input
  • 35.85
  • 0.2466
  • 0.002188
  • 0.01541
  • 0
  • 0.006015
  • 5.332
Input
  • 1.539
  • 0.0144
  • 0.0000575
  • 0.0009001
  • 0.000009196
  • 0.006648
  • -0.011
Output
  • 0.982
  • 0.006946
  • 0.00003289
  • 0.0004341
  • 0
  • 0.0009442
  • -0.02644
Output
  • 33.57
  • 6.549
  • 0.001323
  • 0.4093
  • 0
  • 41.8
  • -2.08
Output
  • 0.006373
  • 0.0009174
  • 0.000007757
  • 0.00005734
  • 0
  • 0.00003831
  • 0.00001381
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.7521
  • 0
  • 0.0005387
  • 0
  • 19.76
  • 0.001485
  • 0
Output
  • 0.244
  • 0
  • 0.00000167
  • 0
  • 0.0165
  • 0.00001203
  • 0
Output
  • 0.1435
  • 0
  • 0.000005726
  • 0
  • 0.032
  • 0.000106
  • 0
Output
  • 2.171
  • 0
  • 0.00008664
  • 0
  • 0.4841
  • 0.001604
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 1829
  • 134.7
  • 1.117
  • 8.417
  • 0.003256
  • 6.176
  • -42.85
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.07933
  • 0.000246
  • 1.245E-7
  • 0.00001538
  • 1.742E-9
  • 0.000002009
  • -0.00008779
Acidification potential, Accumulated Exceedance (AP)
  • 1.33
  • 0.0256
  • 0.0008491
  • 0.0016
  • 0.000006232
  • 0.002087
  • -0.0253
Global Warming Potential - biogenic (GWP-biogenic)
  • 1.76
  • 0.003686
  • 0.00001522
  • 0.0002304
  • 4.025E-7
  • 0.0001567
  • -0.002811
Global Warming Potential - fossil fuels (GWP-fossil)
  • 138.2
  • 8.907
  • 0.08117
  • 0.5567
  • 0.04978
  • 0.2219
  • -5.088
Global Warming Potential - total (GWP-total)
  • 140.1
  • 8.914
  • 0.08119
  • 0.5571
  • 0.04978
  • 0.2221
  • -5.093
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.1161
  • 0.00317
  • 0.000006398
  • 0.0001981
  • 5.91E-8
  • 0.00006098
  • -0.002375
  • 1.4E+2
  • 8.913
  • 0.08119
  • 0.5571
  • 0.04977
  • 0.2221
  • -7.62
Eutrophication potential - freshwater (EP-freshwater)
  • 0.007245
  • 0.00007116
  • 2.955E-7
  • 0.000004447
  • 3.816E-9
  • 0.000002456
  • -0.0003132
Eutrophication potential - marine (EP-marine)
  • 0.1498
  • 0.005065
  • 0.0003748
  • 0.0003166
  • 0.000002992
  • 0.0007226
  • -0.005238
Eutrophication potential - terrestrial (EP-terrestrial)
  • 3.643
  • 0.05665
  • 0.004112
  • 0.003541
  • 0.00003236
  • 0.007948
  • -0.05354
Photochemical Ozone Creation Potential (POCP)
  • 0.6041
  • 0.0217
  • 0.001131
  • 0.001356
  • 0.000007748
  • 0.002307
  • -0.0255
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00001146
  • 0.000002018
  • 1.754E-8
  • 1.261E-7
  • 3.8E-11
  • 9.092E-8
  • -0.0002046
Water (user) deprivation potential (WDP)
  • 1.536E+4
  • 130.3
  • 0.2373
  • 8.141
  • 0.007374
  • 4.164
  • 263.2

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 7.403
  • 0.5886
  • 0.004787
  • 0.03679
  • 0.000005503
  • 0.02558
  • 0.018
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001149
  • 5.453E-7
  • 2.247E-8
  • 3.408E-8
  • 2.4E-11
  • 4.06E-8
  • -4.235E-7
Potential Soil quality index (SQP) 2
  • 1977
  • 94.2
  • 0.1418
  • 5.887
  • 0.0003951
  • 13.12
  • -3.47
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000006669
  • 1.091E-7
  • 5.54E-10
  • 6.816E-9
  • 4.2E-11
  • 2.798E-9
  • 5.315E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.908E-7
  • 0
  • 0
  • 0
  • 1E-12
  • 9E-11
  • -2.447E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 4106
  • 99.83
  • 0.6105
  • 6.239
  • 0.009721
  • 129.9
  • -283.7