| Key Data Set Information | |
| Location | NO |
| Geographical representativeness description | Norway, Northern Europe and North America. The scenarios are based on the Norwegian market. |
| Reference year | 2020 |
| Name |
|
| Technical purpose of product or process | Fibo wall panels are a waterproof panel system based on plywood covered with high-pressure laminate (HPL) on the front and a thinner balancing layer on the back. Fibo wall panels can be used as water proof layer on walls in bathrooms. The panels are also suitable for wardrobes, washing rooms, cleaning rooms, laboratories, commercial kitchens, sport facilities, camping sites, hotels, schools, etc. Wall panels are made both as bathroom panels in a size of 60 cm x 240 cm and as kitchen board in a size of 60 cm x 58 cm. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Manufacturing data is collected in 2019 and is based on average data for 2018. Data for exported energy from waste processing are based on Statistics Norway and are representative for 2017 (2018a, b, c). Data for manufacturing of HPL is collected from an EPD (IBU, 2017). The remaining data are from Ecoinvent v3.5 "Allocation cut-off by classification" (2018), but adjusted to improve representativeness. Modelling and LCA calculations is performed with SimaPro version 9.0.0.48. The allocation is made in accordance with the provisions of EN 15804. No allocation has been utilized in the production at Fibo AS. All incoming and outgoing materials and energy are allocated to the main product. Allocation in upstream processes is used by default in Ecoinvent v3.5. All major raw materials and all the essential energy is included. The production process for raw materials and energy flows that are included with very small amounts (<1%) are not included. This cut-off rule does not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Time representativeness | |
| Data set valid until | 2025 |
| Time representativeness description | "17.03.2020" - "17.03.2025" |
| Technological representativeness | |
| Technology description including background system | Plywood has 7 layers of veener in accordance to NS-EN 13986 with water resistant glue, a thickness of 9 mm and a density of 680 kg/m3. HPL in accordance to EN 438-3 with a thickness of 0.6-0.8 mm on the frontside and a balancing layer of 0.2-0.3 mm on the backside. The density of the HPL is 1350 kg/m3. |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data entry by | |
| Time stamp (last saved) | 2021-08-10T13:00:40 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | c24912e7-abb7-49be-9528-cb8a2db8e624 |
| Date of last revision | 2021-05-03T13:45:57.7583928Z |
| Data set version | 00.03.001 |
| Registration number | NEPD-2105-950-EN |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
Indicators of life cycle