Process Data set: Powerline wall box w/o mounting bracket (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norway, Sweden, Finland
Reference year 2024
Name
Powerline wall box w/o mounting bracket
Use advice for data set The analysis is a cradle-to-gate (A1 - A3) study, with option A4 transport to market. It includes the extraction and production of raw materials, transportation to the production site, the production process itself and transport to the market. A5, installation, is included for the transport of packaging waste from the construction site and the treatment of this waste - not the installation of the products.
Technical purpose of product or process The Powerline wall box has a standard size, with two different fronts—one for single modules and one for one-and-a-half modules. The box can be screwed directly onto the wall or mounted with a wall bracket if preferred. This EPD declares wall box without bracket. The conduit openings have a sealing flap that can be pressed down with a screwdriver to open. The wall box has three openings on each side: two 16 mm and one 20 mm on each side. It can be connected in series if needed. The products covered by this EPD have small variations in composition and are manufactured with the same type of equipment. The composition below represents an average for these products manufactured in 2021.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming electricity and water are allocated according to measured electricity consumption for the actual production department. Water is used for cooling and it is assumed that the amount of water for cooling corresponds to the amount of energy used. Diesel and waste production in-house are allocated equally among all products through mass allocation. Cut-off criteria: All raw materials and all the essential energy are included.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-11-18" - "2029-11-18"
Technological representativeness
Technology description including background system Wall box for electrical installations Designed for use in concealed electrical systems with conduit Diameter: 71 mm (hole saw 73 mm) Mounting screws c-c 60 mm Halogen-free: Yes Material: Polypropylene See our product catalogue on our website: https://www.pipelife.no/

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 19.92
  • 0.003535
  • 0.002292
  • 0
  • 0
  • 0.00153
  • 0.003363
  • -3.689
Input
  • 4.916
  • 0
  • -4.916
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 24.84
  • 0.003535
  • -4.914
  • 0
  • 0
  • 0.00153
  • 0.003363
  • -3.689
Input
  • 29.65
  • 0.247
  • 0.1161
  • 0
  • 0
  • 0.05039
  • 0.07187
  • -0.6905
Input
  • 19.23
  • 0
  • -0.08919
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 48.88
  • 0.247
  • 0.02694
  • 0
  • 0
  • 0.05039
  • 0.07187
  • -0.6905
Input
  • 0.03821
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.05446
  • 0.0001265
  • 0.00006837
  • 0
  • 0
  • 0.0000421
  • 0.00007073
  • -0.0002393
Input
  • 0.07671
  • 0.0004522
  • 0.0006802
  • 0
  • 0
  • 0
  • 0.001149
  • -0.2065
Input
  • 0.1259
  • 0.00002641
  • 0.0000783
  • 0
  • 0
  • 0.0001391
  • 0.0000881
  • -0.004457
Output
  • 0.003966
  • 0.00001274
  • 0
  • 0
  • 0
  • 0
  • 0.007358
  • -0.00008638
Output
  • 0.2092
  • 0.01201
  • 0.3971
  • 0
  • 0
  • 0
  • 0.3001
  • -0.01867
Output
  • 0.00004698
  • 0.000001682
  • 0
  • 0
  • 0
  • 0
  • 4.681E-7
  • -0.000003089
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.006073
  • 0
  • 0.09902
  • 0
  • 0
  • 0.0152
  • 0.00002619
  • 0
Output
  • 0.002861
  • 0
  • 0.297
  • 0
  • 0
  • 0.2919
  • 6.405E-7
  • 0
Output
  • 0.003161
  • 0
  • 0.2075
  • 0
  • 0
  • 0.4752
  • 0.00004155
  • 0
Output
  • 0.04782
  • 0
  • 3.139
  • 0
  • 0
  • 7.19
  • 0.0006286
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 47.18
  • 0.247
  • 0.1161
  • 0
  • 0
  • 0.05038
  • 0.07187
  • -0.6906
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00002074
  • 4.512E-7
  • 1.688E-7
  • 0
  • 0
  • 2.728E-8
  • 2.484E-8
  • -6.084E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.006501
  • 0.00004694
  • 0.00007095
  • 0
  • 0
  • 0.00009378
  • 0.00002443
  • -0.0003992
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.6086
  • 0.000006761
  • 0.6214
  • 0
  • 0
  • 0.000006142
  • 0.000003239
  • -0.00009226
Global Warming Potential - fossil fuels (GWP-fossil)
  • 1.532
  • 0.01633
  • 0.009665
  • 0
  • 0
  • 0.7439
  • 0.03383
  • -0.05291
Global Warming Potential - total (GWP-total)
  • 0.9254
  • 0.01635
  • 0.6311
  • 0
  • 0
  • 0.7439
  • 0.03384
  • -0.05444
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.002531
  • 0.000005814
  • 0.000002575
  • 0
  • 0
  • 9.389E-7
  • 7.263E-7
  • -0.001441
  • 1.471
  • 0.01635
  • 0.4504
  • 0
  • 0
  • 0.7438
  • 0.03386
  • -0.05939
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00004205
  • 1.305E-7
  • 1.078E-7
  • 0
  • 0
  • 6.245E-8
  • 3.658E-8
  • -0.000004395
Eutrophication potential - marine (EP-marine)
  • 0.001313
  • 0.000009289
  • 0.00002975
  • 0
  • 0
  • 0.00004485
  • 0.00004335
  • -0.0001238
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01429
  • 0.0001039
  • 0.0003177
  • 0
  • 0
  • 0.0004852
  • 0.00009649
  • -0.001332
Photochemical Ozone Creation Potential (POCP)
  • 0.005739
  • 0.0000398
  • 0.00008259
  • 0
  • 0
  • 0.0001167
  • 0.00003454
  • -0.0003911
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.816E-8
  • 3.7E-9
  • 1.615E-9
  • 0
  • 0
  • 5.85E-10
  • 9.7E-10
  • -0.003037
Water (user) deprivation potential (WDP)
  • 240.5
  • 0.2389
  • 0.1736
  • 0
  • 0
  • 0.1172
  • 0.6124
  • -6.84

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.05648
  • 0.001079
  • 0.0004371
  • 0
  • 0
  • 0.00008775
  • 0.0003466
  • -0.003767
Potential incidence of disease due to PM emissions (PM) 2
  • 6.858E-8
  • 1E-9
  • 8.89E-10
  • 0
  • 0
  • 4.39E-10
  • 4.8E-10
  • -2.174E-8
Potential Soil quality index (SQP) 2
  • 26.21
  • 0.1728
  • 0.06854
  • 0
  • 0
  • 0.006358
  • 0.2677
  • -3.992
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.832E-8
  • 2E-10
  • 5.98E-10
  • 0
  • 0
  • 6.33E-10
  • 6.6E-11
  • -1.934E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.042E-9
  • 0
  • 1.3E-11
  • 0
  • 0
  • 1.7E-11
  • 2E-12
  • -1.13E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 28.24
  • 0.1831
  • 0.1367
  • 0
  • 0
  • 0.1491
  • 0.08888