Process Data set: Rectangular electric duct heaters VFL, VFLPG, VTL and VRA (en) en

Key Data Set Information
Location SE
Geographical representativeness description Europe
Reference year 2025
Name
Rectangular electric duct heaters VFL, VFLPG, VTL and VRA
Technical purpose of product or process VEAB’s rectangular duct heaters are supplied in customised sizes and with an output of up to 2000 kW. They are used to heat up the inlet air in duct systems, in centralised air handling units and for various industrial processes. When they are properly dimensioned, rectangular duct heaters can handle heating an entire house or building.
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2030
Technological representativeness
Technology description including background system • Output range 0.5 kW – 2000 kW • Protection class IP43 standard, IP55 or IP65 on request • Integrated control equipment or for external feedback control • Integrated overheating protection devices, at least on with automatic reset and one with manual reset • Enclosed stainless tubular heating elements • 50/60 Hz • Can be mounted horizontally or vertically

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 696.9
  • 0.4415
  • 0.005664
  • 0.07359
  • 0.07384
  • 0.05471
  • -26.74
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 696.9
  • 0.4415
  • 0.005664
  • 0.07359
  • 0.07384
  • 0.05471
  • -26.74
Input
  • 2.94E+3
  • 35.1
  • 1.047
  • 5.85
  • 0.7722
  • 1.205
  • -264.9
Input
  • 7.012
  • 0
  • 0
  • 0
  • -3.742
  • 0
  • 0
Input
  • 2948
  • 35.1
  • 1.047
  • 5.85
  • -2.97
  • 1.205
  • -264.9
Input
  • 22.85
  • 0
  • 0.0005142
  • 0
  • 0
  • 0.0003342
  • 0.1352
Input
  • 5.997
  • 0.01544
  • 0.0001393
  • 0.002574
  • 0.001557
  • 0.0009791
  • 1.088
Input
  • 69.16
  • 0.05176
  • 0.00205
  • 0.008627
  • -0.0005001
  • 0.003747
  • 31.32
Input
  • 2.635
  • 0.003994
  • 0.00005389
  • 0.0006657
  • 0.008973
  • 0.002491
  • -0.09462
Output
  • 2.109
  • 0.00192
  • 0.00003082
  • 0.0003201
  • 0.002658
  • 0.03705
  • -0.1571
Output
  • 124.4
  • 3.051
  • 0.00124
  • 0.5085
  • 0.3932
  • 6.197
  • -12.64
Output
  • 0.01127
  • 0.0002397
  • 0.000007271
  • 0.00003994
  • 0.000001523
  • 0.000001812
  • 0.00003716
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 16.29
  • 0
  • 0.0005049
  • 0
  • 50.9
  • 0.00002267
  • -0.005292
Output
  • 1.17
  • 0
  • 0.000001566
  • 0
  • 0.1417
  • 6.751E-7
  • -0.0006968
Output
  • 0.753
  • 0
  • 0.000005367
  • 0
  • 0.6102
  • 0.00002482
  • -0.001707
Output
  • 11.39
  • 0
  • 0.0000812
  • 0
  • 9.232
  • 0.0003756
  • -0.02583

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2946
  • 35.1
  • 1.047
  • 5.85
  • 0.7721
  • 1.205
  • -265
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.1112
  • 0.00003851
  • 1.167E-7
  • 0.000006418
  • 9.638E-7
  • 8.329E-7
  • -0.0009484
Acidification potential, Accumulated Exceedance (AP)
  • 2.039
  • 0.006958
  • 0.0007959
  • 0.00116
  • 0.000495
  • 0.0004083
  • -0.2311
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.698
  • 0.0009256
  • 0.00001426
  • 0.0001543
  • 0.0005458
  • 0.0001379
  • -0.02212
Global Warming Potential - fossil fuels (GWP-fossil)
  • 229.2
  • 2.161
  • 0.07608
  • 0.3601
  • 1.283
  • 0.1194
  • -31.06
Global Warming Potential - total (GWP-total)
  • 230.3
  • 2.162
  • 0.0761
  • 0.3604
  • 1.283
  • 0.1196
  • -31.11
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.3621
  • 0.0006584
  • 0.000005996
  • 0.0001097
  • 0.00005197
  • 0.00006104
  • -0.02874
  • 230.2
  • 2.162
  • 0.0761
  • 0.3604
  • 1.283
  • 0.1198
  • -45.65
Eutrophication potential - freshwater (EP-freshwater)
  • 0.01573
  • 0.00001719
  • 2.77E-7
  • 0.000002866
  • 0.000002344
  • 0.000001255
  • -0.002389
Eutrophication potential - marine (EP-marine)
  • 0.2743
  • 0.001524
  • 0.0003513
  • 0.0002539
  • 0.0001785
  • 0.0001523
  • -0.03455
Eutrophication potential - terrestrial (EP-terrestrial)
  • 5.579
  • 0.01699
  • 0.003855
  • 0.002832
  • 0.001853
  • 0.001467
  • -0.3705
Photochemical Ozone Creation Potential (POCP)
  • 1.004
  • 0.006673
  • 0.00106
  • 0.001112
  • 0.0004694
  • 0.0004255
  • -0.1654
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00001589
  • 5.21E-7
  • 1.644E-8
  • 8.683E-8
  • 1.368E-8
  • 1.591E-8
  • -0.001014
Water (user) deprivation potential (WDP)
  • 3.375E+4
  • 26.91
  • 0.2225
  • 4.485
  • 2.255
  • 3.728
  • 1135

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 17.37
  • 0.1534
  • 0.004487
  • 0.02557
  • 0.003016
  • 0.005191
  • 0.05875
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00002346
  • 1.985E-7
  • 2.106E-8
  • 3.308E-8
  • 3.502E-9
  • 7.015E-9
  • -0.000002691
Potential Soil quality index (SQP) 2
  • 5017
  • 40.24
  • 0.1329
  • 6.706
  • 0.282
  • 3.302
  • -29.25
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.00001529
  • 2.481E-8
  • 5.19E-10
  • 4.135E-9
  • 9.678E-9
  • 4.367E-8
  • 0.000002231
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.000001708
  • 0
  • 0
  • 0
  • 1.42E-10
  • 6.65E-10
  • -1.555E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1.063E+4
  • 25.66
  • 0.5723
  • 4.277
  • 12.21
  • 55.65
  • -2389