| Key Data Set Information | |
| Location | CN |
| Geographical representativeness description | Nordic + Northwestern Europe. |
| Reference year | 2024 |
| Name |
|
| Technical purpose of product or process | Junistar Bio sets a new standard for easy installation of downlights. New, patented, springs minimize the installation time. Junistar Bio can be installed in all false ceilings >2 mm, directly in insulation or in a downlightbox. The springs also work in concrete holes, and can therefore replace fixtures with flange springs. Build-in height of 56 mm. Install and dismount in a few seconds - without hurting the fingers.It includes a junction box that provides strain relief for several types of cables, as well as fixtion for plastic tubing. Junistar Bio has super efficiency with high quality of light and no flicker. Phase cut dimmable and tiltable steps in two directions, totally 2x25°. The luminaire is developed with focus on sustainability and is produced with bio-circular material; made of waste and residues of biological origin. It also has less material than a traditional downlight: ~40% weight reduction. Virgin polycarbonate is used as a proxy for bio-circular material due to the lack of LCA data for the bio material. System Wattage: 5 W. Luminous flux: 500lm. Efficacy: 100 lm/W. Colour temperature: 2700K. Colour rendering: Ra>9. MacAdams factor: SDCM: 2. Lifetime: L80/B20>50.000. Light distribution: Direct. Control/Dimming: Trailing edge dimming. Luminiare class: Class II. Housing: Polycarbonat (PC).Height: 59 mm. Diameter: 94 mm. EAN: 7021989052500. The EPD also covers the following products: EAN: 7021989052517 - JUNISTAR BIO HVIT 3000K EAN: 7021989052524 - JUNISTAR BIO HVIT 4000K EAN: 7021989052531 - JUNISTAR BIO SORT 2700K EAN: 7021989052548 - JUNISTAR BIO SORT 3000K EAN: 7021989052555 - JUNISTAR BIO SORT 4000K Please note that the above has been calculated with the Norwegian energy-mix. If you want an EPD with a specific energy-mix, please send us a request. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) can be excluded. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-06-24" - "2029-06-24" |
| Technological representativeness | |
| Technology description including background system | Link to product data on our website: https://www.sg-as.com/products/junistar-bio/905250/pdf/specification_905250.pdf Link to CE Declaration: https://www.sg-as.com/storage/data/703020_Junistar%20Bio/50/703020_Junistar%20Bio.pdf |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-11-18T15:55:45 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | af60b4a5-eb5a-461f-b128-1a9f032e6498 |
| Date of last revision | 2024-06-20T10:10:01.6980524Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-6964-6353 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle