Close Go back Collapse all sections
Process Data set: PP Sewer and Storm Water pipe (non-pressure) (en) en

Key Data Set Information
Location NO
Geographical representativeness description Mainly Norway.
Reference year 2024
Name
PP Sewer and Storm Water pipe (non-pressure)
Use advice for data set The system boundary for this EPD is modules A1-A4. A4: Distance for transport from manufacturer to building site has been set to 300 km. This distance is given in newer PCRs as a default value for Norway. A5: Has not been included, but can be provided for project specific EPD on request. This, due to various installation practices. C1-C4: Has not been included as it is assumed that the pressure pipes are left as is after end of life.
Technical purpose of product or process PP sewer and storm water pipes for all non-pressure underground sewer and storm water systems. The PP pipes are orange-brown or black according to the product standards. This EPD is for orange-brown pipes, and representative for all dimensions. Project specific EPD for other colours can be provided. For more information: www.hallingplast.no The product standard for these non-pressure pipes is NS-EN 1852.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on registered EPDs according to EN 15804, Ostfold Research databases, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-06-02" - "2029-06-02"
Technological representativeness
Technology description including background system The material density for these products is 900 kg/m3. The dimensions given for these products, i.e. diameter and wall thickness, are mean values based on the dimensions given in the product standards. For additional technical information: www.hallingplast.no

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 3.054
  • 0.01087
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 3.054
  • 0.01087
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 45.44
  • 0.7595
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 33.51
  • 0
  • 0
  • 0
  • 0
  • -32.7
  • 0
  • 0
Input
  • 78.95
  • 0.7595
  • 0
  • 0
  • 0
  • -32.7
  • 0
  • 0
Input
  • 0.000298
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.06476
  • 0.0003889
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.01634
  • 0.001391
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.03617
  • 0.00008122
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.002162
  • 0.00003917
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.2096
  • 0.03693
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00004943
  • 0.000005173
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.001717
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.003765
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.002441
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.03693
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 76.16
  • 0.7594
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00002379
  • 0.000001387
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Acidification potential, Accumulated Exceedance (AP)
  • 0.008658
  • 0.0001444
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.01023
  • 0.00002079
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.2
  • 0.05023
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - total (GWP-total)
  • 2.211
  • 0.05027
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0006492
  • 0.00001788
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.083
  • 0.05026
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0000326
  • 4.013E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - marine (EP-marine)
  • 0.001519
  • 0.00002856
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01685
  • 0.0003195
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Photochemical Ozone Creation Potential (POCP)
  • 0.007353
  • 0.0001224
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.789E-8
  • 1.138E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Water (user) deprivation potential (WDP)
  • 91.89
  • 0.7346
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.05115
  • 0.003319
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 7.474E-8
  • 3.075E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 4.087
  • 0.5312
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.441E-8
  • 6.15E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.11E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 12.1
  • 0.563
  • 0
  • 0
  • 0
  • 0
  • 0