Close Go back Collapse all sections
Process Data set: AXLJ-TTCL TSLF 1x185/35 AFR 36kV (en) en

Key Data Set Information
Location SE
Geographical representativeness description Scandinavia (B6 calculations done with Danish el.mix)
Reference year 2024
Name
AXLJ-TTCL TSLF 1x185/35 AFR 36kV
Technical purpose of product or process Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before, during and after installation. Ripcords for easier and safer stripping of the outer sheath. Conductor design: Round, stranded aluminum conductor, class 2 Conductor material: Aluminium Core insulation material: XLPE Screen construction: Aluminium tape and copper wire Material outer sheath: MDPE Laminated sheath: Yes Longitudinal water blocking screen: Yes Rip cord: Yes UV resistant: Yes
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-09-06" - "2029-09-06"
Technological representativeness
Technology description including background system AXLJ-TTCL TSLF 18/30(36) KV SAPcode 20102189 STANDARDS, CERTIFICATIONS AND APPROVALS: SS 424 14 16 Construction standard 12-36 kV CENELEC HD 620 Part 10 Section K Harmonized construction standard CENELEC HD 620 Part 10 Section M Harmonized construction and testing standard

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 24.11
  • 0.05687
  • 4.036
  • 0.0302
  • 0.5655
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2139
  • 0
  • 0
  • 0.01806
  • 0.002866
  • 0.01679
  • -19.19
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 24.11
  • 0.05687
  • 4.036
  • 0.0302
  • 0.5655
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2139
  • 0
  • 0
  • 0.01806
  • 0.002865
  • 0.01679
  • -19.19
Input
  • 154.9
  • 3.658
  • 8.528
  • 2.4
  • 3.422
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2491
  • 0
  • 0
  • 1.28
  • 0.09459
  • 0.1974
  • -34.57
Input
  • 41.28
  • 0
  • 0
  • 0
  • 0.03054
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -39.75
  • 0
  • 0
Input
  • 196.2
  • 3.658
  • 8.528
  • 2.4
  • 3.453
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2491
  • 0
  • 0
  • 1.28
  • -39.65
  • 0.1974
  • -34.57
Input
  • 0.1377
  • 0
  • 0
  • 0
  • 0.002779
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001217
  • 0.01107
Input
  • 0.2343
  • 0.001673
  • 0.01584
  • 0.001056
  • 0.005079
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.008042
  • 0
  • 0
  • 0.0006465
  • 0.00007955
  • 0.0003501
  • -0.005079
Input
  • 0.05063
  • 0.008657
  • 0.05099
  • 0.003541
  • 0.002359
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00004257
  • 0
  • 0
  • 0.002308
  • 0
  • 0.00183
  • -0.3994
Input
  • 0.1632
  • 0.0004319
  • 0.009868
  • 0.0002732
  • 0.003489
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0007936
  • 0
  • 0
  • 0.0001348
  • 0.0002855
  • 0.0002486
  • -0.07487
Output
  • 0.09006
  • 0.0002199
  • 0.04071
  • 0.0001314
  • 0.003083
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003293
  • 0
  • 0
  • 0.00006528
  • 0
  • 0.02296
  • 0.01049
Output
  • 2.662
  • 0.1907
  • 0.06208
  • 0.2087
  • 0.07826
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00152
  • 0
  • 0
  • 0.06117
  • 0
  • 0.7283
  • -0.8015
Output
  • 0.0003808
  • 0.00002458
  • 0.0001268
  • 0.00001638
  • 0.00001117
  • 0
  • 0
  • 0
  • 0
  • 0
  • 7.845E-7
  • 0
  • 0
  • 0.000008727
  • 0
  • 0.000001329
  • -0.0001417
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.002675
  • 0
  • 0.01015
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5047
  • 0.00004469
  • -0.0004333
Output
  • 0
  • 0
  • 0.1526
  • 0
  • 0.01251
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4729
  • 0.00003183
  • -0.00005705
Output
  • 0
  • 0
  • 0.08888
  • 0
  • 0.02004
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.9129
  • 0.0003407
  • -0.0001398
Output
  • 0
  • 0
  • 1.345
  • 0
  • 0.3032
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 13.81
  • 0.005154
  • -0.002115

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 193.7
  • 3.657
  • 8.509
  • 2.399
  • 4.198
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.249
  • 0
  • 0
  • 1.28
  • 0.09458
  • 0.1974
  • -34.57
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0005742
  • 0.000004052
  • 0.000003012
  • 0.000002634
  • 0.00001173
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.711E-7
  • 0
  • 0
  • 0.000002299
  • 5.146E-8
  • 6.732E-8
  • -0.00003239
Acidification potential, Accumulated Exceedance (AP)
  • 0.1193
  • 0.002304
  • 0.0005433
  • 0.0006485
  • 0.002468
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00007704
  • 0
  • 0
  • 0.000347
  • 0.00018
  • 0.00006692
  • -0.02464
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.1133
  • 0.0001107
  • 0.01867
  • 0.00006331
  • 0.002643
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001991
  • 0
  • 0
  • 0.00003461
  • 0.00001181
  • 0.00000529
  • -0.0123
Global Warming Potential - fossil fuels (GWP-fossil)
  • 13.74
  • 0.2515
  • 0.1618
  • 0.1543
  • 0.3175
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01921
  • 0
  • 0
  • 0.08488
  • 1.42
  • 0.0584
  • -2.72
Global Warming Potential - total (GWP-total)
  • 13.93
  • 0.2517
  • 0.1852
  • 0.1544
  • 0.3216
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01943
  • 0
  • 0
  • 0.08494
  • 1.42
  • 0.05841
  • -2.784
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.06922
  • 0.0001025
  • 0.004654
  • 0.00004504
  • 0.001481
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002587
  • 0
  • 0
  • 0.00002967
  • 0.000001754
  • 0.000002553
  • -0.05223
  • 13.85
  • 0.2517
  • 0.1812
  • 0.1544
  • 0.32
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02688
  • 0
  • 0
  • 0.08494
  • 1.42
  • 0.05917
  • -2.641
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0007759
  • 0.000002197
  • 0.000005292
  • 0.000001176
  • 0.00001571
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000001572
  • 0
  • 0
  • 6.666E-7
  • 1.116E-7
  • 1.242E-7
  • -0.0001506
Eutrophication potential - marine (EP-marine)
  • 0.01454
  • 0.0007104
  • 0.0001347
  • 0.000195
  • 0.000317
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001296
  • 0
  • 0
  • 0.0001029
  • 0.00008641
  • 0.00007999
  • -0.0027
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1706
  • 0.007852
  • 0.001334
  • 0.002156
  • 0.003685
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000185
  • 0
  • 0
  • 0.001138
  • 0.0009333
  • 0.0002664
  • -0.03085
Photochemical Ozone Creation Potential (POCP)
  • 0.05241
  • 0.00219
  • 0.0003216
  • 0.0006934
  • 0.001125
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003943
  • 0
  • 0
  • 0.0003484
  • 0.0002235
  • 0.00008708
  • -0.009994
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.809E-7
  • 5.422E-8
  • 3.719E-8
  • 3.564E-8
  • 1.662E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.53E-10
  • 0
  • 0
  • 1.935E-8
  • 1.12E-9
  • 2.549E-9
  • -0.005834
Water (user) deprivation potential (WDP)
  • 2085
  • 2.784
  • 849.4
  • 1.841
  • 58.87
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.87
  • 0
  • 0
  • 1.221
  • 0.2303
  • 3.094
  • -1504

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.3906
  • 0.0158
  • 0.2873
  • 0.01049
  • 0.01422
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001218
  • 0
  • 0
  • 0.005595
  • 0.0001626
  • 0.001104
  • -0.1517
Potential incidence of disease due to PM emissions (PM) 2
  • 9.626E-7
  • 1.96E-8
  • 4.254E-9
  • 1.358E-8
  • 2.016E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.77E-10
  • 0
  • 0
  • 6.111E-9
  • 7.09E-10
  • 1.248E-9
  • -2.345E-7
Potential Soil quality index (SQP) 2
  • 33.52
  • 2.95
  • 3.839
  • 2.752
  • 0.8906
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4094
  • 0
  • 0
  • 0.8824
  • 0.01168
  • 0.5733
  • -8.68
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 9.933E-7
  • 2.946E-9
  • 3.983E-9
  • 1.697E-9
  • 2.009E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.9E-10
  • 0
  • 0
  • 1.018E-9
  • 1.233E-9
  • 2.31E-10
  • -1.534E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.686E-8
  • 0
  • 1.64E-10
  • 0
  • 5.41E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9E-12
  • 0
  • 0
  • 0
  • 3.3E-11
  • 1E-11
  • -7.526E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 813
  • 2.798
  • 5.037
  • 1.755
  • 19.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4432
  • 0
  • 0
  • 0.9427
  • 0.3227
  • 151.1
  • -104