Process Data set: SafeRing/SafePlus 12/24 kV type CCV 20kA Arc Classified (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norway
Reference year 2024
Name
SafeRing/SafePlus 12/24 kV type CCV 20kA Arc Classified
Technical purpose of product or process ABB SafeRing/SafePlus Switchgear is a medium voltage gas insulated ring main unit for secondary distribution. The main function of the switchgears is to “establish and cut off the supply of a downstream installation from an electrical and/or mechanical control and to protect people and premises at risk of fire or explosion against insulation defects”. SafeRing/SafePlus can be supplied in a number of different configurations suitable for most switching applications in 12/24 kV distribution networks. SafeRing/SafePlus 12 / 24 kV type CCV 20 kA Arc Classified switchgear consist of two load-break switch units (C-module) plus one circuit breaker (V-module). The manufacturer proclaims a minimum product service life of 30 years but the calculations are based on 20 years as the PCR dictates. The functional unit of this study is described as 1 piece of SafeRing/SafePlus 12 / 24 kV type CCV 20 kA Arc Classified including heat loss during a 20 year product lifetime. The functional unit is IAC classified.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804, Norsus, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through time allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 2%) might not be included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 14.25874084483 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-01-02 - 2029-01-02
Technological representativeness
Technology description including background system Parameter Amount Rated voltage: 12 / 24 kV Rated frequency: 50 Hz Rated nominal current: 630 A Rated power frequency withstand voltage: 28 / 50 kV Rated lightning impulse withstand voltage: 95 / 125 kV Rated short-time withstand current: 25 / 21 kA Rated duration of short-circuit: 3 s Rated peak withstand current: 62.5 / 52.5 kA Insulating medium: SF6 Rated filling pressure at 20 degree Celsius: 0.14 MPa (absolute) Internal arc classification: IAC AFL 20 kA, 1.0 s

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 5463
  • 2.037
  • 0.2241
  • 0
  • 5.879E+4
  • 0
  • 2.037
  • 4.169
  • 3.119
  • -773.3
Input
  • 478.8
  • 0
  • -478.8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 5942
  • 2.037
  • -478.5
  • 0
  • 5.879E+4
  • 0
  • 2.037
  • 4.169
  • 3.119
  • -773.3
Input
  • 3.051E+4
  • 144.3
  • 10.91
  • 0
  • 4287
  • 0
  • 144.3
  • 99.65
  • 25.78
  • -2822
Input
  • 630.8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 3.066E+4
  • 144.3
  • 10.91
  • 0
  • 4287
  • 0
  • 144.3
  • 99.65
  • 25.78
  • -2822
Input
  • 76.37
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01394
  • 14.54
Input
  • 15.45
  • 0.07289
  • 0.006537
  • 0
  • 45.97
  • 0
  • 0.07289
  • 0.004475
  • 0.06449
  • 8.405
Input
  • 138.6
  • 0.2602
  • 0.07445
  • 0
  • 121
  • 0
  • 0.2602
  • 0
  • 0.03404
  • 199.6
Input
  • 31.32
  • 0.0152
  • 0.00794
  • 0
  • 439.3
  • 0
  • 0.0152
  • 0.1028
  • 0.03485
  • -3.275
Output
  • 8.651
  • 0.007361
  • 0
  • 0
  • 0.8093
  • 0
  • 0.007361
  • 0.0003442
  • 0.1829
  • -1.372
Output
  • 7713
  • 6.898
  • 34.49
  • 0
  • 337.9
  • 0
  • 6.898
  • 4.571
  • 96.72
  • -121.3
Output
  • 0.07739
  • 0.0009841
  • 0
  • 0
  • 0.04002
  • 0
  • 0.0009841
  • 0.0005698
  • 0.0001852
  • -0.002895
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.0008094
  • 0
  • 0
  • 0
  • 0
  • 283.4
  • 0.000953
  • -0.5691
Output
  • 0.5054
  • 0
  • 34.21
  • 0
  • 0
  • 0
  • 0
  • 20.3
  • 0.0003466
  • -0.07493
Output
  • 1.7
  • 0
  • 23.8
  • 0
  • 0
  • 0
  • 0
  • 29.41
  • 0.004349
  • -0.1836
Output
  • 11.69
  • 0
  • 3.6E+2
  • 0
  • 0
  • 0
  • 0
  • 350.7
  • 0.0658
  • -2.778

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 3.051E+4
  • 144.3
  • 10.91
  • 0
  • 4.28E+3
  • 0
  • 144.3
  • 99.67
  • 25.77
  • -2823
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.363
  • 0.0002593
  • 0.00001505
  • 0
  • 0.007714
  • 0
  • 0.0002593
  • 0.00004482
  • 0.000009383
  • -0.05012
Acidification potential, Accumulated Exceedance (AP)
  • 46.03
  • 0.03912
  • 0.007462
  • 0
  • 1.236
  • 0
  • 0.03912
  • 0.03576
  • 0.01207
  • -9.711
Global Warming Potential - biogenic (GWP-biogenic)
  • -50.78
  • 0.003902
  • 52.29
  • 0
  • 9.125
  • 0
  • 0.003902
  • 0.0005916
  • 63.33
  • -0.5907
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.56E+3
  • 9.571
  • 0.9281
  • 1.81E+3
  • 307.6
  • 0
  • 9.571
  • 48.35
  • 5.531
  • -303.6
Global Warming Potential - total (GWP-total)
  • 2512
  • 9.578
  • 53.21
  • 1.81E+3
  • 318.1
  • 0
  • 9.578
  • 48.36
  • 68.86
  • -305.4
Global Warming Potential - land use and land use change (GWP-luluc)
  • 2.542
  • 0.003346
  • 0.000238
  • 0
  • 1.353
  • 0
  • 0.003346
  • 0.004124
  • 0.0004022
  • -1.232
  • 2561
  • 9.578
  • 0.9283
  • 1581
  • 357.2
  • 0
  • 9.578
  • 48.25
  • 4.364
  • -375
Eutrophication potential - freshwater (EP-freshwater)
  • 0.8026
  • 0.00007516
  • 0.00001112
  • 0
  • 0.01312
  • 0
  • 0.00007516
  • 0.0004457
  • 0.0004211
  • -0.07072
Eutrophication potential - marine (EP-marine)
  • 4.321
  • 0.0116
  • 0.003202
  • 0
  • 0.2152
  • 0
  • 0.0116
  • 0.008829
  • 0.107
  • -0.5986
Eutrophication potential - terrestrial (EP-terrestrial)
  • 53.65
  • 0.1283
  • 0.0343
  • 0
  • 2.692
  • 0
  • 0.1283
  • 0.09568
  • 0.03734
  • -7.969
Photochemical Ozone Creation Potential (POCP)
  • 15.93
  • 0.03929
  • 0.008816
  • 0
  • 0.7061
  • 0
  • 0.03929
  • 0.0251
  • 0.02857
  • -2.625
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.0001775
  • 0.000002182
  • 1.482E-7
  • 0
  • 0.0000205
  • 0
  • 0.000002182
  • 0.000002446
  • 3.217E-7
  • -0.1713
Water (user) deprivation potential (WDP)
  • 2.104E+4
  • 137.7
  • 16.79
  • 0
  • 7.92E+5
  • 0
  • 137.7
  • 29.43
  • 630.7
  • -1.796E+4

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 112.8
  • 0.6309
  • 0.03953
  • 0
  • 81.81
  • 0
  • 0.6309
  • 0.4222
  • 0.1725
  • -3.003
Potential incidence of disease due to PM emissions (PM) 2
  • 0.0002434
  • 6.89E-7
  • 9.123E-8
  • 0
  • 0.00001149
  • 0
  • 6.89E-7
  • 3.005E-7
  • 1.611E-7
  • -0.00003804
Potential Soil quality index (SQP) 2
  • 2.216E+4
  • 99.5
  • 6.114
  • 0
  • 2011
  • 0
  • 99.5
  • 21.31
  • 84.03
  • -1.33E+3
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.0004995
  • 1.148E-7
  • 6.629E-8
  • 1E-12
  • 0.00000769
  • 0
  • 1.148E-7
  • 2.097E-7
  • 3.986E-8
  • -0.00007386
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.00002037
  • 0
  • 1.38E-9
  • 1E-12
  • 4.055E-7
  • 0
  • 0
  • 1.434E-8
  • 3.135E-9
  • -0.000002175
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 4.694E+5
  • 106.3
  • 12.42
  • 0.005712
  • 7467
  • 0
  • 106.3
  • 450.7
  • 1837
  • -8.881E+4