Close Go back Collapse all sections
Process Data set: Prefix Tec-Flex PP 40 5G10 0,6/1,0kV RV-K (en) en

Key Data Set Information
Location ES
Geographical representativeness description Nordic
Reference year 2025
Name
Prefix Tec-Flex PP 40 5G10 0,6/1,0kV RV-K
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Tec Flex RV-K 0,6/1 kV power cables are specially indicated for its use in distribution networks, power stations, industries or buildings, and electrical installations in steel ships. For electrical energy transport and distribution, distribution networks, protected or not. For indoor and outdoor installations. Non-suitable for facilities of feeding of submerged pumps Surface mounted (directly installed or on cable trays, cable ladders, cleats, brackets or in cable ducting (conduit, pipes or similar closed systems)). Embedded (directly or in cable ducting). In building voids and cavities (directly or on cable trays, cable ladders, in cable ducting). Buried in ground (directly or in conduit) General: UNE 21-123-91; IEC 60502-21-123-91/1; HD 603-1 Flexible installation cable 0,6/1,0kV
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.03720750003 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-29 - 2030-04-29
Technological representativeness
Technology description including background system Cable Standard IEC 60502-1 Conductor Annealed electrolytic flexible multi-stranded copper conductor, class 5, IEC 60228 Insulation XLPE – according to standard IEC 60502-1 Coloured According to HD 308 S2 Colour code Cenelec. Yellow/Green; Blue, brown, Black, Grey Bedding PVC Jacket PVC, White or Grey. UV stabilized. (PVC type ST2 according to IEC 60502-1) Marking RV-K 0,6/1,0kV xx G mm² Year/lot Rated Voltage U0/U 0,6/1,0kV Volatge test 3500V Service temp 90° C Short circuit temp 250° C Fire performance EN 50575:2014+A1:2016 Flame retardant EN 60332-1-2 CPR EN50575 Eca Temperature – service -25- 60° Temperature – installation 0 - 50° Bending radius 10 x D Marking – Approvals – directives RohS Low Voltage Directive CPR compliant Marine approval Registered for use in Swan Buildings

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 7.485
  • 0.01594
  • 1.039
  • 0.03011
  • 0.1675
  • 1.403
  • 0
  • 0.009143
  • 0.02573
  • 0.01097
  • -3.275
Input
  • 1.249
  • 0
  • 0
  • 0
  • -1.224
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 8.735
  • 0.01594
  • 1.039
  • 0.03011
  • -1.057
  • 1.403
  • 0
  • 0.009143
  • 0.02572
  • 0.01097
  • -3.275
Input
  • 40.78
  • 1.228
  • 3.61
  • 2.103
  • 0.8469
  • 0.1085
  • 0
  • 0.6387
  • 0.2141
  • 0.1111
  • -5.191
Input
  • 10.76
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -10.76
  • 0
  • -1.029
Input
  • 51.55
  • 1.228
  • 3.61
  • 2.103
  • 0.8469
  • 0.1085
  • 0
  • 0.6387
  • -10.55
  • 0.1111
  • -6.22
Input
  • 0.07899
  • 0
  • 0
  • 0
  • 0.001596
  • 0
  • 0
  • 0
  • 0
  • 0.000826
  • 0.1174
Input
  • 0.2047
  • 0.0005536
  • 0.006338
  • 0.001077
  • 0.0041
  • 0.001102
  • 0
  • 0.0003271
  • 0.0004699
  • 0.0002339
  • 0.009087
Input
  • 0.00881
  • 0.002349
  • 0.01698
  • 0.003852
  • 0.0008037
  • 0.002745
  • 0
  • 0.00117
  • 0
  • 0.0005679
  • -0.08321
Input
  • 0.04954
  • 0.0001194
  • 0.002282
  • 0.0002249
  • 0.00108
  • 0.01048
  • 0
  • 0.0000683
  • 0.004775
  • 0.0001359
  • -0.01264
Output
  • 0.03249
  • 0.00006139
  • 0.0002057
  • 0.0001085
  • 0.0008132
  • 0.00006957
  • 0
  • 0.00003294
  • 0
  • 0.009613
  • -0.004596
Output
  • 0.9126
  • 0.04966
  • 0.01479
  • 0.1023
  • 0.1166
  • 0.008347
  • 0
  • 0.03106
  • 0
  • 0.3439
  • -0.2022
Output
  • 0.0001453
  • 0.000008394
  • 0.00002776
  • 0.00001433
  • 0.000003775
  • 9.702E-7
  • 0
  • 0.000004351
  • 0
  • 6.783E-7
  • -0.000006514
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00006814
  • 0
  • 0
  • 0
  • 0.0049
  • 0
  • 0
  • 0
  • 0.2768
  • 0.00001641
  • -0.004612
Output
  • 0.0001597
  • 0
  • 0
  • 0
  • 0.09203
  • 0
  • 0
  • 0
  • 0.166
  • 0.00002098
  • -0.0006806
Output
  • 0.000297
  • 0
  • 0
  • 0
  • 0.06517
  • 0
  • 0
  • 0
  • 0.2333
  • 0.0002066
  • -0.001614
Output
  • 0.004494
  • 0
  • 0
  • 0
  • 0.986
  • 0
  • 0
  • 0
  • 3.529
  • 0.003126
  • -0.02442

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 50.88
  • 1.228
  • 3.61
  • 2.103
  • 0.953
  • 0.1083
  • 0
  • 0.6387
  • 0.2141
  • 0.1111
  • -6.133
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0009218
  • 0.000001974
  • 0.000001309
  • 0.000003843
  • 0.00001855
  • 5.919E-7
  • 0
  • 0.000001167
  • 3.253E-7
  • 4.015E-8
  • -0.0003782
Acidification potential, Accumulated Exceedance (AP)
  • 0.1058
  • 0.0007406
  • 0.001402
  • 0.0003998
  • 0.002166
  • 0.00006202
  • 0
  • 0.0001214
  • 0.0001177
  • 0.00003943
  • -0.06776
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.08768
  • 0.00003236
  • 0.0004613
  • 0.00005758
  • 0.1347
  • 0.0002194
  • 0
  • 0.00001748
  • 0.0000632
  • 0.000003144
  • -0.002189
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.825
  • 0.08383
  • 0.1557
  • 0.1391
  • 0.06459
  • 0.007937
  • 0
  • 0.04224
  • 0.3948
  • 0.02429
  • -0.484
Global Warming Potential - total (GWP-total)
  • 2.74
  • 0.08389
  • 0.1576
  • 0.1392
  • 0.1993
  • 0.00819
  • 0
  • 0.04227
  • 0.3949
  • 0.0243
  • -0.4873
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.002691
  • 0.00003563
  • 0.001389
  • 0.00004951
  • 0.00008241
  • 0.00003274
  • 0
  • 0.00001503
  • 0.00001204
  • 0.000001652
  • -0.001143
  • 2.847
  • 0.08389
  • 0.1631
  • 0.1392
  • 0.06534
  • 0.008173
  • 0
  • 0.04227
  • 0.3952
  • 0.01326
  • -0.2698
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00086
  • 6.047E-7
  • 0.000007449
  • 0.000001111
  • 0.00001733
  • 5.709E-7
  • 0
  • 3.375E-7
  • 4.623E-7
  • 1.021E-7
  • -0.0004568
Eutrophication potential - marine (EP-marine)
  • 0.007156
  • 0.0001723
  • 0.0001996
  • 0.00007911
  • 0.0001575
  • 0.000006817
  • 0
  • 0.00002402
  • 0.00003594
  • 0.00003327
  • -0.002858
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1038
  • 0.00192
  • 0.002255
  • 0.0008849
  • 0.00223
  • 0.00008873
  • 0
  • 0.0002687
  • 0.0003868
  • 0.0001527
  • -0.04391
Photochemical Ozone Creation Potential (POCP)
  • 0.02727
  • 0.0005508
  • 0.0006045
  • 0.000339
  • 0.0005798
  • 0.00002386
  • 0
  • 0.0001029
  • 0.0001026
  • 0.00004694
  • -0.01201
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.538E-7
  • 1.881E-8
  • 1.701E-8
  • 3.151E-8
  • 8.713E-9
  • 5.44E-10
  • 0
  • 9.568E-9
  • 5.128E-9
  • 1.372E-9
  • -0.001491
Water (user) deprivation potential (WDP)
  • 182.1
  • 1.021
  • -81.88
  • 2.034
  • 2.033
  • 18.89
  • 0
  • 0.6177
  • 4.074
  • 2.034
  • 16.48

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.1595
  • 0.005348
  • 0.03894
  • 0.009193
  • 0.004244
  • 0.001966
  • 0
  • 0.002792
  • 0.0009889
  • 0.0006463
  • -0.007431
Potential incidence of disease due to PM emissions (PM) 2
  • 2.997E-7
  • 4.092E-9
  • 3.254E-9
  • 8.517E-9
  • 6.348E-9
  • 4.45E-10
  • 0
  • 2.586E-9
  • 7.01E-10
  • 6.51E-10
  • -1.468E-7
Potential Soil quality index (SQP) 2
  • 27.99
  • 0.736
  • 0.7787
  • 1.471
  • 0.6303
  • 0.05457
  • 0
  • 0.4467
  • 0.07405
  • 0.2989
  • -9.879
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001659
  • 8.19E-10
  • 2.649E-9
  • 1.703E-9
  • 3.346E-8
  • 5.55E-10
  • 0
  • 5.17E-10
  • 2.438E-9
  • 2.13E-10
  • -7.516E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.186E-8
  • 0
  • 7.9E-11
  • 0
  • 4.42E-10
  • 2.4E-11
  • 0
  • 0
  • 2.7E-11
  • 8E-12
  • -8.788E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1232
  • 0.8756
  • 3.022
  • 1.559
  • 26.96
  • 0.4936
  • 0
  • 0.4734
  • 9.524
  • 101.1
  • -621.7