Close Go back Collapse all sections
Process Data set: Medium-voltage switchgear UniGear ZS1 24.12.32 BT 800mm(w/LPITs, CB) (en) en

Key Data Set Information
Location CH
Geographical representativeness description Europe
Reference year 2025
Name
Medium-voltage switchgear UniGear ZS1 24.12.32 BT 800mm(w/LPITs, CB)
Use advice for data set The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage.
Technical purpose of product or process This Environmental Product Declaration is a “specific product EPD”, and the declared product is the Air-insulated switchgear UniGear ZS1 24.12.32 BT 800mm (w/LPITs, CB), including related accessories and packaging. General technical information of the Air-insulated switchgear UniGear ZS1 24.12.32 BT 800mm (w/LPITs, CB) are presented below. The constituent materials of UG ZS1 24.12.32 BT 800mm (with KECA 80C184, KEVA 24B, VD4/P 24.06.25 p.210) is presented below. Weights of VD4/P 24.06.25 p.210, 3 pcs of KEVA 24B and 3 pcs of KECA 80C184 are included to bellow table. Type Material Weight [kg] Weight % Metals Steel (Magnelis®) 387.25 49.65 Steel, stainless steel 227.24 29.13 Copper 62.14 7.97 Aluminum 9.17 1.18 Brass 4.58 0.59 Other metals 0.40 0.05 Plastics Plastics (PA, PP, PVC, ABS) 71.53 9.17 Rubber 3.38 0.43 Others Epoxy resin 9.61 1.23 Safety glass 3.16 0.41 Ceramics 0.92 0.12 Others 0.66 0.08 Total 780.04 100
Classification
Class name : Hierarchy level
  • EPDNorge: Construction
General comment on data set Both primary and secondary data are used. The main sources for primary data are the bill of materials, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. According to PCR, the cut-off criteria can be set to a maximum of 2 % of the overall environmental impacts. In this LCA, stickers have been excluded as their weights are negligible. Process black oxide and phosphate conversion coating have also been excluded due to the model complexity and unavailability of data.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-05-20 - 2030-05-20
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Input
  • 1.187E+4
  • 11.6
  • 1.18
  • 3.82E+4
  • 78.7
Input
  • 3.67E+3
  • 0
  • 0
  • 0
  • 0
Input
  • 1.554E+4
  • 11.6
  • 1.18
  • 3.82E+4
  • 78.7
Input
  • 5.493E+4
  • 7.5E+2
  • 62.7
  • 1.99E+5
  • 844
Input
  • 2008
  • 0
  • 0
  • 0
  • 0
Input
  • 1.554E+4
  • 7.5E+2
  • 62.7
  • 1.99E+5
  • 844
Input
  • 200.9
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 45.32
  • 0.107
  • -0.0243
  • 156
  • 0.404
Output
  • 0.443
  • 0.00477
  • 0.000375
  • 0.252
  • 0.00316
Output
  • 1.2E+3
  • 36.7
  • 3.94
  • 546
  • 111
Output
  • 0.154
  • 0.000244
  • 0.0000199
  • 1.45
  • 0.00158
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 477
  • 0
  • 0
  • 0
  • 573
Output
  • 37.1
  • 0
  • 157
  • 0
  • 1.63
Output
  • 78.4
  • 0
  • 353
  • 0
  • 7.18
Output
  • 148
  • 0
  • 635
  • 0
  • 12.9

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Abiotic depletion potential - fossil resources (ADPF)
  • 5.69E+4
  • 7.5E+2
  • 62.7
  • 1.99E+5
  • 844
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.8297
  • 0.00017
  • 0.0000137
  • 0.0172
  • 0.0006
Acidification potential, Accumulated Exceedance (AP)
  • 74.73
  • 0.218
  • 0.0381
  • 43.4
  • 0.337
Global Warming Potential - biogenic (GWP-biogenic)
  • -226.9
  • 0.0479
  • 227
  • 319
  • 23.7
Global Warming Potential - fossil fuels (GWP-fossil)
  • 4.66E+3
  • 52.6
  • 10.8
  • 8.65E+3
  • 74.5
Global Warming Potential - total (GWP-total)
  • 4444
  • 52.6
  • 238
  • 8.99E+3
  • 98.4
Global Warming Potential - land use and land use change (GWP-luluc)
  • 5.242
  • 0.0257
  • 0.00209
  • 21.6
  • 0.0896
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 5.886
  • 0.0037
  • 0.00126
  • 7.89
  • 0.0231
Eutrophication potential - marine (EP-marine)
  • 6.711
  • 0.083
  • 0.0184
  • 7.72
  • 0.173
Eutrophication potential - terrestrial (EP-terrestrial)
  • 79.36
  • 0.886
  • 0.182
  • 68.1
  • 0.891
Photochemical Ozone Creation Potential (POCP)
  • 24.98
  • 0.319
  • 0.0514
  • 21.9
  • 0.284
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.0000982
  • 0.00000115
  • 1.09E-7
  • 0.000155
  • 8.45E-7
Water (user) deprivation potential (WDP)
  • 1383
  • 3.04
  • -1.52
  • 2.03E+3
  • 10.9

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0