Close Go back Collapse all sections
Process Data set: Langfoss Maxi 27000 (en) en

Key Data Set Information
Location CN
Geographical representativeness description Nordic + Northwestern Europe
Reference year 2025
Name
Langfoss Maxi 27000
Technical purpose of product or process Langfoss Maxi is a powerful floodlight luminaire suitable for lighting large spaces, transport and storage areas, playgrounds, courts and car parks. Can also be used as facade lighting. Nordic design for Nordic conditions.The sloping top allows snow to slide off, and the bracket can withstand heavy loads. Asymmetrical optics send the light where it is needed, and the mounting bracket can be angled as required. Super simple installation with two-piece mounting bracket with hooks. Die-cast powder-coated aluminium with tempered glass front. Accessories for flexible installation: bracket for side mounting on post, corner bracket and extension cable. System Wattage: 192.0 W. Luminous flux: 24980lm. Efficacy: 130 lm/W. Colour temperature: 3000K. Colour rendering: Ra>70. MacAdams factor: SDCM: 3. Lifetime: L90/B50>50,000, . Light distribution: Asymmetric. Control/Dimming: On/Off. Luminiare class: Class I. Housing: Die-cast aluminium. Optics: Tempered glass. Height: 85.0mm. Length: 552.0 mm. Width: 443.0 mm. EAN: 7021986419207 The EPD also covers the following product: EAN: 7021986419436 - LANGFOSS MAXI 27000 4000K  Please note that the above has been calculated with the Norwegian Energy-mix. If you want an EPD with a specific energy-mix, please send us a request.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) can be excluded. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.940193920409 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-01-13 - 2030-01-13
Technological representativeness
Technology description including background system Link to product data on our website: https://www.sg-as.com/products/langfoss-maxi/641920/pdf/specification_641920.pdf Link to CE Declaration: https://www.sg-as.com/assets/product/default/data/701269_Langfoss%20Maxi/50/701269_Langfoss%20Maxi.pdf

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 322.1
  • 0.02228
  • 5.16
  • 1.017
  • 0.007566
  • 1.461E+4
  • 0
  • 0.128
  • 0.5416
  • 0.6154
  • -6.741
Input
  • 11.93
  • 0
  • 0
  • 0
  • -11.93
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 334.1
  • 0.02228
  • 5.16
  • 1.017
  • -11.92
  • 1.461E+4
  • 0
  • 0.128
  • 0.5416
  • 0.6154
  • -6.741
Input
  • 2336
  • 1.969
  • 51.27
  • 89.49
  • 0.4596
  • 1.13E+3
  • 0
  • 11.31
  • 3.371
  • 2.494
  • -77.49
Input
  • 30.02
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -36.21
  • 0
  • 0.006556
Input
  • 2366
  • 1.969
  • 51.27
  • 89.49
  • 0.4596
  • 1.13E+3
  • 0
  • 11.31
  • -32.84
  • 2.494
  • -77.48
Input
  • 8.026
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.013
  • 0.04432
Input
  • 1.81
  • 0.0004358
  • 0.004536
  • 0.0335
  • 0.0002509
  • 11.47
  • 0
  • 0.002503
  • 0.007708
  • 0.003516
  • 0.07303
Input
  • 3.397
  • 0.003701
  • 0.0427
  • 0.1795
  • 0.001034
  • 28.58
  • 0
  • 0.02125
  • -0.000329
  • 0.1132
  • 1.669
Input
  • 1.891
  • 0.0002202
  • 0.1398
  • 0.007694
  • 0.0002168
  • 109.1
  • 0
  • 0.001264
  • 0.003315
  • 0.002125
  • -0.03202
Output
  • 1.372
  • 0.0001779
  • 0.007083
  • 0.004364
  • 0
  • 0.7243
  • 0
  • 0.001022
  • 0.0001552
  • 0.6967
  • -0.04064
Output
  • 39.71
  • 0.09451
  • 0.479
  • 2.763
  • 2.031
  • 86.89
  • 0
  • 0.5428
  • 0.211
  • 3.65
  • -1.367
Output
  • 0.006324
  • 0.00001292
  • 0.00003921
  • 0.0006141
  • 0
  • 0.0101
  • 0
  • 0.00007421
  • 0.000007952
  • 0.000006138
  • -0.0001752
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.1527
  • 0
  • 1.889
  • 0
  • 0
  • 0
  • 7.847
  • 0.00002681
  • -0.001752
Output
  • 0
  • 0
  • 0.03294
  • 0
  • 0.0004432
  • 0
  • 0
  • 0
  • 0.2989
  • 6.557E-7
  • -0.0002301
Output
  • 0
  • 0
  • 0.04962
  • 0
  • 0.1161
  • 0
  • 0
  • 0
  • 0.4907
  • 0.00004254
  • -0.0005705
Output
  • 0
  • 0
  • 0.7507
  • 0
  • 1.757
  • 0
  • 0
  • 0
  • 7.424
  • 0.0006435
  • -0.008631

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2366
  • 1.969
  • 51.27
  • 89.48
  • 0.4596
  • 1128
  • 0
  • 11.31
  • 3.37
  • 2.492
  • -77.47
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.04471
  • 0.000003574
  • 0.00001791
  • 0.0001208
  • 7.995E-7
  • 0.006162
  • 0
  • 0.00002053
  • 0.000002577
  • 0.000001121
  • -0.007637
Acidification potential, Accumulated Exceedance (AP)
  • 1.794
  • 0.0003986
  • 0.03026
  • 0.09768
  • 0.0001556
  • 0.6456
  • 0
  • 0.002289
  • 0.001456
  • 0.0009702
  • -0.3602
Global Warming Potential - biogenic (GWP-biogenic)
  • -2.078
  • 0.00005189
  • 0.001442
  • 0.002247
  • 3.446
  • 2.284
  • 0
  • 0.000298
  • 0.0006704
  • 0.0001736
  • -0.02167
Global Warming Potential - fossil fuels (GWP-fossil)
  • 201
  • 0.1332
  • 5.793
  • 6.337
  • 0.03285
  • 82.63
  • 0
  • 0.7653
  • 1.096
  • 0.2057
  • -6.838
Global Warming Potential - total (GWP-total)
  • 199.3
  • 0.1333
  • 5.795
  • 6.339
  • 3.479
  • 85.25
  • 0
  • 0.7659
  • 1.097
  • 0.2071
  • -6.842
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.4077
  • 0.00004872
  • 0.000913
  • 0.003156
  • 0.00001086
  • 0.3409
  • 0
  • 0.0002798
  • 0.0009744
  • 0.001151
  • 0.01722
  • 202.6
  • 0.1333
  • 5.473
  • 6.339
  • 0.03286
  • 85.08
  • 0
  • 0.7658
  • 1.097
  • 0.2148
  • -7.747
Eutrophication potential - freshwater (EP-freshwater)
  • 0.02667
  • 0.00000125
  • 0.0001286
  • 0.00004044
  • 2.697E-7
  • 0.005943
  • 0
  • 0.000007179
  • 0.00001063
  • 0.000006496
  • -0.002059
Eutrophication potential - marine (EP-marine)
  • 0.2236
  • 0.00007848
  • 0.00625
  • 0.0235
  • 0.00005145
  • 0.07096
  • 0
  • 0.0004507
  • 0.0003059
  • 0.0002884
  • -0.02023
Eutrophication potential - terrestrial (EP-terrestrial)
  • 2.584
  • 0.0008776
  • 0.06887
  • 0.2617
  • 0.000557
  • 0.9237
  • 0
  • 0.00504
  • 0.003397
  • 0.002773
  • -0.2745
Photochemical Ozone Creation Potential (POCP)
  • 0.7965
  • 0.0003286
  • 0.01814
  • 0.07072
  • 0.0001601
  • 0.2484
  • 0
  • 0.001887
  • 0.0009319
  • 0.001063
  • -0.07968
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00002001
  • 2.898E-8
  • 8.49E-8
  • 0.000001396
  • 6.934E-9
  • 0.000005666
  • 0
  • 1.664E-7
  • 2.178E-8
  • 2.006E-8
  • -0.003878
Water (user) deprivation potential (WDP)
  • 7546
  • 0.642
  • 8.356
  • 59.26
  • 0.5824
  • 1.966E+5
  • 0
  • 3.687
  • 32.72
  • 22.73
  • 768

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 7.987
  • 0.008183
  • 0.04435
  • 0.3879
  • 0.001966
  • 20.46
  • 0
  • 0.04699
  • 0.01733
  • 0.008641
  • -0.1904
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001163
  • 8.616E-9
  • 4.086E-7
  • 2.24E-7
  • 2.295E-9
  • 0.000004629
  • 0
  • 4.948E-8
  • 9.675E-9
  • 1.759E-8
  • -9.023E-7
Potential Soil quality index (SQP) 2
  • 680.8
  • 1.349
  • 10.86
  • 43.18
  • 0.3083
  • 568.1
  • 0
  • 7.747
  • 0.7743
  • 5.761
  • -63.84
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.00001055
  • 1.56E-9
  • 7.104E-8
  • 4.468E-8
  • 7.7E-10
  • 0.000005778
  • 0
  • 8.996E-9
  • 3.13E-7
  • 5.379E-9
  • -9.448E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.506E-7
  • 0
  • 1.629E-9
  • 0
  • 1.8E-11
  • 2.453E-7
  • 0
  • 0
  • 5.32E-9
  • 6.48E-10
  • -2.11E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1.317E+4
  • 1.596
  • 150.3
  • 60.96
  • 0.6129
  • 5139
  • 0
  • 9.166
  • 7.014
  • 1522
  • -2666