Close Go back Collapse all sections
Process Data set: IFSI-EMC Pure 1kV 3x1.5/1,5mm² ER (en) en

Key Data Set Information
Location FI
Geographical representativeness description Norway
Reference year 2024
Name
IFSI-EMC Pure 1kV 3x1.5/1,5mm² ER
Technical purpose of product or process IFSI-EMC PURE 1KV CU Power cable with up to 1 kV operating voltage. Allowed indoors, outdoors and as a ground cable without extra protection. The Cu screen is 100% tight, has low coupling impedance and meets the EMC directive. The 3-conductor is symmetrically constructed and has a CU screen from 1.5mm². Halogen-free cable is recommended used when it is important to avoid the formation of dense smoke and corrosive gases in the event of an overheating or fire. Conductor material Copper Conductor surface: Bare Core insulation material: XLPE Armoring material: Copper, bare Screen construction: Metallized foil Screen material: Copper, bare Concentric conductor: Copper Material inner sheath: Halogen-free polymer Material outer sheath: Halogen-free polymer Cable shape: Round
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 4.96698113E-4 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-09-06" - "2029-09-06"
Technological representativeness
Technology description including background system IFSI-EMC Pure 1kV 3x1.5/1.5mm² ER SAP code: 20216062 El no. 1003806 STANDARDS APPLIED: HD 604-5D Construction IEC 60502-1 Construction IEC 60228 Class 1 or Class 2 Conductors EN 50575:2014 + A1:2016 CPR standard - Fire properties EN 60754-1 and EN 60754-2 Halogen free properties: EN 60754-1 (pH = 4,3, Conductivity = 10µS), EN 60754-2 ( < 0,5% Halogen) IEC 61034-1, -2 Low smoke properties: IEC 61034-1, -2 (minimum 60% light transmittance)

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.345
  • 0.008614
  • 0.1793
  • 0.005958
  • 0.03078
  • 0
  • 0
  • 0
  • 0
  • 0
  • 52.37
  • 0
  • 0
  • 0.002042
  • 0.001158
  • 0.001724
  • -0.8853
Input
  • 0.01487
  • 0
  • 0
  • 0
  • 0.00001497
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.01412
  • 0
  • 0
Input
  • 1.36
  • 0.008614
  • 0.1793
  • 0.005958
  • 0.03079
  • 0
  • 0
  • 0
  • 0
  • 0
  • 52.37
  • 0
  • 0
  • 0.002042
  • -0.01296
  • 0.001724
  • -0.8853
Input
  • 6.913
  • 0.7767
  • 2.29
  • 0.4734
  • 0.2047
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.05
  • 0
  • 0
  • 0.1447
  • 0.02147
  • 0.02281
  • -0.2689
Input
  • 2.486
  • 0
  • 0
  • 0
  • 0.004611
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.0212
  • 0
  • -2.234
  • 0
  • 0
Input
  • 9.399
  • 0.7767
  • 2.29
  • 0.4734
  • 0.2093
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.05
  • 0
  • -0.0212
  • 0.1447
  • -2.213
  • 0.02281
  • -0.2689
Input
  • 0.01417
  • 0
  • 0.0003641
  • 0
  • 0.0002906
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0044
Input
  • 0.02853
  • 0.0002883
  • 0.0001488
  • 0.0002084
  • 0.0005825
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.04113
  • 0
  • 0
  • 0.00007308
  • 0.00002511
  • 0.0000358
  • 0.0002727
Input
  • 0.003322
  • 0.0008591
  • 0.000177
  • 0.0006986
  • 0.00009478
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1025
  • 0
  • 0
  • 0.0002609
  • 0
  • 0.00005417
  • -0.04839
Input
  • 0.03828
  • 0.00006462
  • 0.0008111
  • 0.0000539
  • 0.0007876
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3912
  • 0
  • 0
  • 0.00001524
  • 0.0001731
  • 0.00002878
  • -0.001369
Output
  • 0.002972
  • 0.00003645
  • 0.002127
  • 0.00002591
  • 0.0001925
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002597
  • 0
  • 0
  • 0.00000738
  • 0
  • 0.004475
  • -0.0001767
Output
  • 0.122
  • 0.02344
  • 0.01154
  • 0.04118
  • 0.005253
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3115
  • 0
  • 0
  • 0.006916
  • 0
  • 0.08915
  • -0.01043
Output
  • 0.00002329
  • 0.000005343
  • 0.00003894
  • 0.000003232
  • 0.000001383
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003621
  • 0
  • 0
  • 9.866E-7
  • 0
  • 1.558E-7
  • -8.556E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01135
  • 0
  • 0.0008443
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03086
  • 0.000005963
  • -0.0001722
Output
  • 0
  • 0
  • 0.009548
  • 0
  • 0.001585
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.06972
  • 1.458E-7
  • -0.00002267
Output
  • 0
  • 0
  • 0.006382
  • 0
  • 0.002274
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1073
  • 0.000009461
  • -0.00005555
Output
  • 0
  • 0
  • 0.09655
  • 0
  • 0.03441
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.624
  • 0.0001431
  • -0.0008404

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 9.331
  • 0.7766
  • 2.29
  • 0.4734
  • 0.2531
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.044
  • 0
  • 0
  • 0.1447
  • 0.02138
  • 0.02281
  • -0.2689
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001069
  • 0.000001013
  • 3.172E-7
  • 5.197E-7
  • 0.00000217
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002209
  • 0
  • 0
  • 2.599E-7
  • 1.669E-8
  • 7.676E-9
  • -0.00001424
Acidification potential, Accumulated Exceedance (AP)
  • 0.0154
  • 0.0009291
  • 0.00007898
  • 0.0001279
  • 0.0003305
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002315
  • 0
  • 0
  • 0.00003923
  • 0.00003446
  • 0.000007757
  • -0.002603
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.003728
  • 0.00001896
  • 0.000961
  • 0.00001249
  • 0.0002621
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00819
  • 0
  • 0
  • 0.000003913
  • 0.006849
  • 0.001541
  • -0.00008934
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.5641
  • 0.05482
  • 0.01054
  • 0.03043
  • 0.01625
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2962
  • 0
  • 0
  • 0.009596
  • 0.1616
  • 0.007927
  • -0.02445
Global Warming Potential - total (GWP-total)
  • 0.5684
  • 0.05486
  • 0.01151
  • 0.03045
  • 0.01652
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3056
  • 0
  • 0
  • 0.009603
  • 0.1684
  • 0.009469
  • -0.02488
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0005911
  • 0.00002567
  • 0.00001446
  • 0.000008885
  • 0.00001273
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001222
  • 0
  • 0
  • 0.000003354
  • 6.179E-7
  • 2.748E-7
  • -0.0003401
  • 0.5684
  • 0.05486
  • 0.01132
  • 0.03045
  • 0.01647
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.305
  • 0
  • 0
  • 0.009603
  • 0.1655
  • 0.009736
  • -0.01675
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001376
  • 3.38E-7
  • 3.652E-7
  • 2.321E-7
  • 0.00000277
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000213
  • 0
  • 0
  • 7.536E-8
  • 2.987E-8
  • 1.339E-8
  • -0.00001785
Eutrophication potential - marine (EP-marine)
  • 0.001091
  • 0.0002462
  • 0.00002473
  • 0.00003847
  • 0.0000283
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002544
  • 0
  • 0
  • 0.00001163
  • 0.00001645
  • 0.00001262
  • -0.0001291
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01548
  • 0.002732
  • 0.0002759
  • 0.0004254
  • 0.0003789
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003311
  • 0
  • 0
  • 0.0001287
  • 0.0001693
  • 0.00003072
  • -0.001882
Photochemical Ozone Creation Potential (POCP)
  • 0.00422
  • 0.0007223
  • 0.0000656
  • 0.0001368
  • 0.0001027
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0008905
  • 0
  • 0
  • 0.00003939
  • 0.00004081
  • 0.00001076
  • -0.0005124
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.178E-8
  • 1.191E-8
  • 9.61E-9
  • 7.032E-9
  • 1.141E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.031E-8
  • 0
  • 0
  • 2.188E-9
  • 3.33E-10
  • 3E-10
  • -0.0006858
Water (user) deprivation potential (WDP)
  • 27.87
  • 0.5126
  • 1.101
  • 0.3631
  • 0.6022
  • 0
  • 0
  • 0
  • 0
  • 0
  • 704.9
  • 0
  • 0
  • 0.138
  • 0.1408
  • 0.3182
  • -0.853

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.02725
  • 0.003373
  • 0.1011
  • 0.002069
  • 0.002656
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07336
  • 0
  • 0
  • 0.0006325
  • 0.0000528
  • 0.0001237
  • -0.001027
Potential incidence of disease due to PM emissions (PM) 2
  • 4.995E-8
  • 2.917E-9
  • 1.17E-9
  • 2.679E-9
  • 1.11E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.659E-8
  • 0
  • 0
  • 6.91E-10
  • 1.53E-10
  • 1.48E-10
  • -9.747E-9
Potential Soil quality index (SQP) 2
  • 3.985
  • 0.3667
  • 0.8474
  • 0.543
  • 0.1099
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.036
  • 0
  • 0
  • 0.09976
  • 0.003829
  • 0.07134
  • -1.195
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.311E-7
  • 5.91E-10
  • 4.25E-10
  • 3.35E-10
  • 4.654E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.071E-8
  • 0
  • 0
  • 1.15E-10
  • 4.01E-10
  • 2.3E-11
  • -2.879E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 3.369E-9
  • 0
  • 1.6E-11
  • 0
  • 6.8E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.79E-10
  • 0
  • 0
  • 0
  • 8E-12
  • 0
  • -3.39E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 174.5
  • 0.5219
  • 0.8187
  • 0.3462
  • 3.78
  • 0
  • 0
  • 0
  • 0
  • 0
  • 18.42
  • 0
  • 0
  • 0.1066
  • 0.3115
  • 12.76
  • -23.96