Close Go back Collapse all sections
Process Data set: KGF 120mm² (en) en

Key Data Set Information
Location FI
Geographical representativeness description Finland
Reference year 2025
Name
KGF 120mm²
Technical purpose of product or process Grounding wire for fixed installations. Conductor: Copper
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system SAP code: 20075453 El no: 2811115 IEC 60228

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 14.54
  • 0.04202
  • 0.9965
  • 0.03311
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01135
  • 0
  • 0.01976
  • -0.751
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 14.54
  • 0.04202
  • 0.9965
  • 0.03311
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01135
  • 0
  • 0.01976
  • -0.751
Input
  • 58.03
  • 3.772
  • 12.73
  • 2.631
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.8041
  • 0
  • 0.1413
  • -1.873
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 58.03
  • 3.772
  • 12.73
  • 2.631
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.8041
  • 0
  • 0.1413
  • -1.873
Input
  • 0.169
  • 0
  • 0.002023
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.06136
Input
  • 0.3648
  • 0.001408
  • 0.0008269
  • 0.001158
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004061
  • 0
  • 0.0004097
  • 0.005834
Input
  • 0
  • 0.004214
  • 0.0009836
  • 0.003882
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00145
  • 0
  • 0
  • 0.0126
Input
  • 0.08105
  • 0.0003151
  • 0.004507
  • 0.0002995
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00008468
  • 0
  • 0.0001853
  • -0.005129
Output
  • 0.03922
  • 0.0001772
  • 0.01182
  • 0.000144
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00004101
  • 0
  • 0.01599
  • -0.002375
Output
  • 2.129
  • 0.1148
  • 0.06412
  • 0.2288
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03843
  • 0
  • 0.4327
  • -0.1011
Output
  • 0.0002645
  • 0.00002595
  • 0.0002164
  • 0.00001796
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005483
  • 0
  • 9.871E-7
  • -0.000002105
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.06305
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6398
  • 0
  • -0.002401
Output
  • 0
  • 0
  • 0.05306
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.0003162
Output
  • 0
  • 0
  • 0.03546
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.0007747
Output
  • 0
  • 0
  • 0.5365
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.01172

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 57.99
  • 3.772
  • 12.73
  • 2.63
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.8041
  • 0
  • 0.1413
  • -1.873
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.002227
  • 0.000004952
  • 0.000001763
  • 0.000002888
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000001444
  • 0
  • 4.661E-8
  • -0.0001972
Acidification potential, Accumulated Exceedance (AP)
  • 0.2299
  • 0.004463
  • 0.0004389
  • 0.0007109
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000218
  • 0
  • 0.00004755
  • -0.03521
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.09579
  • 0.00009222
  • 0.00534
  • 0.00006941
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002174
  • 0
  • 0
  • -0.0009749
Global Warming Potential - fossil fuels (GWP-fossil)
  • 4.404
  • 0.266
  • 0.05855
  • 0.1691
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05333
  • 0
  • 0.006126
  • -0.2097
Global Warming Potential - total (GWP-total)
  • 4.505
  • 0.2662
  • 0.06397
  • 0.1692
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05337
  • 0
  • 0.006128
  • -0.2109
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.004653
  • 0.0001241
  • 0.00008035
  • 0.00004937
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001864
  • 0
  • 0.000002384
  • -0.0002213
  • 4.497
  • 0.2662
  • 0.06293
  • 0.1692
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05337
  • 0
  • 0.007358
  • -0.09948
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00187
  • 0.000001647
  • 0.00000203
  • 0.00000129
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.188E-7
  • 0
  • 1.111E-7
  • -0.0002373
Eutrophication potential - marine (EP-marine)
  • 0.01533
  • 0.001184
  • 0.0001374
  • 0.0002138
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00006465
  • 0
  • 0.00001704
  • -0.001446
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.2281
  • 0.01314
  • 0.001533
  • 0.002364
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000715
  • 0
  • 0.0001919
  • -0.02243
Photochemical Ozone Creation Potential (POCP)
  • 0.05523
  • 0.003475
  • 0.0003645
  • 0.0007601
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002189
  • 0
  • 0.00005428
  • -0.006091
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.77E-7
  • 5.783E-8
  • 5.341E-8
  • 3.908E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.216E-8
  • 0
  • 1.712E-9
  • -1.068E-8
Water (user) deprivation potential (WDP)
  • 303.5
  • 2.508
  • 6.116
  • 2.018
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.7671
  • 0
  • 3.661
  • 11.48

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.2845
  • 0.01639
  • 0.5616
  • 0.0115
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003515
  • 0
  • 0.0009473
  • -0.002327
Potential incidence of disease due to PM emissions (PM) 2
  • 6.265E-7
  • 1.423E-8
  • 6.495E-9
  • 1.489E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.839E-9
  • 0
  • 8.22E-10
  • -7.04E-8
Potential Soil quality index (SQP) 2
  • 53.99
  • 1.792
  • 4.709
  • 3.018
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5544
  • 0
  • 0.2449
  • -4.11
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000003985
  • 2.882E-9
  • 2.364E-9
  • 1.861E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.4E-10
  • 0
  • 2.12E-10
  • -3.918E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.245E-8
  • 0
  • 9.5E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.2E-11
  • -4.571E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2882
  • 2.539
  • 4.55
  • 1.924
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5922
  • 0
  • 264.1
  • -323.9