| Key Data Set Information | |
| Location | ES |
| Geographical representativeness description | Nordic |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | Cradle to Gate. The following stages have been declared: A1-A4 |
| Technical purpose of product or process | SOLFLEX H1Z2Z2-K is intended for fixed or mobile (heavy duty) photovoltaic (PV) installations in ground, rooftopsystems or other architectural integrations. They are suitable for indoor or outdoor installations. Ideal for solar trackers which require flexibility and aptitude for mobile service. It is recommended for panel interconnection in PV installations or from the string boxes to the inverter. SOLFLEX H1Z2Z2-K is designed to operate at a normal maximum conductor temperature of 90ºC, - but for a maximum of 20.000 hours a max. conductor temperature of 120ºC at a max. ambient temperature of 90ºC is permitted. Life expectancy greater than 25 years. The expected period of use under normal usage conditions as specified in the technical datasheet is at least 25 years. Intended for use in PV installations acc. to HD 60364-7-712. - Interconnection between PV panels (panel wire). - Interconnection between PV panels and the connection box - Direct installation between PV panels and the (DC/AC) inverter when there is no connection box Construction and tests. Standards: EN 50618 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº305/2011: Reaction to fire - Eca Certified by AENOR <HAR> (Nº 042/001106 – Product range: From 1x1,5 up to 1x50 mm2) RoHS compliant |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging! |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-04-10 - 2030-04-10 |
| Technological representativeness | |
| Technology description including background system | Construction standards EN 50618 Conductor Tinned copper EN 60228 C 5 Insulation - conductor XLPE, Cross linked polyolefin Conductor marking Jacket Cross linked Polyolefin UV resistant Marking Soflex H1Z2Z2-K 1X xy MM7AA EN50618 Voltage - nominel Uo/U 1,5vD.C. 0,6/1kV A.C. Voltage - test 1,8 kV D.C. Max Conductor temperature operation "90° at normal operation 120° instant at 90° ambient temp. And 20.000Hours" Short circuit 5s max Resistant to fire performance Flame retartant EN 60332-1-2 CPR EN 50575 compliance Eca DoP MEHZ2Z2K Temperature - operation Min - 40ºC - Max. + 90ºC Temperature - installation Min -25ºC - Max. + 30ºC Bending radius 8xD |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-05-19T10:30:33 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 80f067f8-d658-4bf6-a60f-23a08159a76e |
| Date of last revision | 2025-04-09T11:55:24.2874202Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-9737-9642 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle