Close Go back Collapse all sections
Process Data set: Solflex 1 x 6 H1Z2Z2-K Black 1,5kV D.C 0,6/1,0kV A.C. Halogenfree (en) en

Key Data Set Information
Location ES
Geographical representativeness description Nordic
Reference year 2025
Name
Solflex 1 x 6 H1Z2Z2-K Black 1,5kV D.C 0,6/1,0kV A.C. Halogenfree
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process SOLFLEX H1Z2Z2-K is intended for fixed or mobile (heavy duty) photovoltaic (PV) installations in ground, rooftopsystems or other architectural integrations. They are suitable for indoor or outdoor installations. Ideal for solar trackers which require flexibility and aptitude for mobile service. It is recommended for panel interconnection in PV installations or from the string boxes to the inverter. SOLFLEX H1Z2Z2-K is designed to operate at a normal maximum conductor temperature of 90ºC, - but for a maximum of 20.000 hours a max. conductor temperature of 120ºC at a max. ambient temperature of 90ºC is permitted. Life expectancy greater than 25 years. The expected period of use under normal usage conditions as specified in the technical datasheet is at least 25 years. Intended for use in PV installations acc. to HD 60364-7-712. - Interconnection between PV panels (panel wire). - Interconnection between PV panels and the connection box - Direct installation between PV panels and the (DC/AC) inverter when there is no connection box Construction and tests. Standards: EN 50618 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº305/2011: Reaction to fire - Eca Certified by AENOR <HAR> (Nº 042/001106 – Product range: From 1x1,5 up to 1x50 mm2) RoHS compliant
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 9.50858334E-4 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system Construction standards EN 50618 Conductor Tinned copper EN 60228 C 5 Insulation - conductor XLPE, Cross linked polyolefin Conductor marking Jacket Cross linked Polyolefin UV resistant Marking Soflex H1Z2Z2-K 1X xy MM7AA EN50618 Voltage - nominel Uo/U 1,5vD.C. 0,6/1kV A.C. Voltage - test 1,8 kV D.C. Max Conductor temperature operation "90° at normal operation 120° instant at 90° ambient temp. And 20.000Hours" Short circuit 5s max Resistant to fire performance Flame retartant EN 60332-1-2 CPR EN 50575 compliance Eca DoP MEHZ2Z2K Temperature - operation Min - 40ºC - Max. + 90ºC Temperature - installation Min -25ºC - Max. + 30ºC Bending radius 8xD

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.7083
  • 0.001285
  • 0.9462
  • 0.002211
  • 0.0332
  • 0.5678
  • 0
  • 0.0006714
  • 0.00004176
  • 0.0009478
  • -0.28
Input
  • 0.03193
  • 0
  • 0
  • 0
  • -0.03129
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.7402
  • 0.001285
  • 0.9462
  • 0.002211
  • 0.001913
  • 0.5678
  • 0
  • 0.0006714
  • 0.00004176
  • 0.0009478
  • -0.28
Input
  • 3.253
  • 0.1015
  • 3.603
  • 0.1545
  • 0.1437
  • 0.04391
  • 0
  • 0.0469
  • 0.001421
  • 0.007956
  • -0.4461
Input
  • 0.6238
  • 0
  • 0
  • 0
  • 0.0002446
  • 0
  • 0
  • 0
  • -0.6116
  • 0
  • 0
Input
  • 3.877
  • 0.1015
  • 3.603
  • 0.1545
  • 0.1439
  • 0.04391
  • 0
  • 0.0469
  • -0.6101
  • 0.007956
  • -0.4461
Input
  • 0.007887
  • 0
  • 0
  • 0
  • 0.0001577
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01404
Input
  • 0.01976
  • 0.00004429
  • 0.006265
  • 0.0000791
  • 0.0005242
  • 0.0004459
  • 0
  • 0.00002402
  • 0.000001177
  • 0.00001968
  • 0.001316
Input
  • 0.0006768
  • 0.0001959
  • 0.0168
  • 0.0002828
  • 0.0003656
  • 0.001111
  • 0
  • 0.00008588
  • 0
  • 0.0000284
  • -0.00353
Input
  • 0.004405
  • 0.000009636
  • 0.001591
  • 0.00001652
  • 0.0001213
  • 0.004241
  • 0
  • 0.000005016
  • 0.000004013
  • 0.00001028
  • -0.001304
Output
  • 0.0026
  • 0.000005033
  • 0.0002012
  • 0.000007966
  • 0.00007458
  • 0.00002815
  • 0
  • 0.000002419
  • 0
  • 0.0009138
  • -0.0005444
Output
  • 0.09388
  • 0.00391
  • 0.01424
  • 0.007512
  • 0.005242
  • 0.003378
  • 0
  • 0.002281
  • 0
  • 0.02624
  • -0.02354
Output
  • 0.00001366
  • 6.944E-7
  • 0.00002769
  • 0.000001052
  • 8.668E-7
  • 3.926E-7
  • 0
  • 3.195E-7
  • 0
  • 5.482E-8
  • -5.735E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0.0005595
  • 0
  • 0
  • 0
  • 0.02797
  • 6.458E-7
  • -0.0005495
Output
  • 0
  • 0
  • 0
  • 0
  • 0.002444
  • 0
  • 0
  • 0
  • 0.0072
  • 1.58E-8
  • -0.00007235
Output
  • 0
  • 0
  • 0
  • 0
  • 0.001879
  • 0
  • 0
  • 0
  • 0.01396
  • 0.000001025
  • -0.0001773
Output
  • 0
  • 0
  • 0
  • 0
  • 0.02842
  • 0
  • 0
  • 0
  • 0.2112
  • 0.0000155
  • -0.002682

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 3.821
  • 0.1015
  • 3.603
  • 0.1545
  • 0.1551
  • 0.04384
  • 0
  • 0.0469
  • 0.001421
  • 0.007956
  • -0.4462
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00009829
  • 1.578E-7
  • 0.00000127
  • 2.822E-7
  • 0.000002002
  • 2.395E-7
  • 0
  • 8.568E-8
  • 7.6E-10
  • 2.659E-9
  • -0.00004515
Acidification potential, Accumulated Exceedance (AP)
  • 0.01072
  • 0.00007136
  • 0.001398
  • 0.00002936
  • 0.0002452
  • 0.0000251
  • 0
  • 0.000008915
  • 0.00000272
  • 0.000002685
  • -0.008068
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.001316
  • 0.000002648
  • 0.0004468
  • 0.000004228
  • 0.003522
  • 0.0000888
  • 0
  • 0.000001284
  • 1.756E-7
  • 8.07E-8
  • -0.0002256
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.2359
  • 0.00698
  • 0.1552
  • 0.01022
  • 0.008719
  • 0.003212
  • 0
  • 0.003102
  • 0.02172
  • 0.001104
  • -0.04921
Global Warming Potential - total (GWP-total)
  • 0.2374
  • 0.006984
  • 0.157
  • 0.01022
  • 0.01227
  • 0.003314
  • 0
  • 0.003104
  • 0.02172
  • 0.001104
  • -0.04953
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0002403
  • 0.000003065
  • 0.001387
  • 0.000003636
  • 0.00003271
  • 0.00001325
  • 0
  • 0.000001104
  • 2.579E-8
  • 1.224E-7
  • -0.00009283
  • 0.2391
  • 0.006983
  • 0.1625
  • 0.01022
  • 0.008931
  • 0.003307
  • 0
  • 0.003104
  • 0.02172
  • 0.001159
  • -0.02402
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00008739
  • 4.909E-8
  • 0.000007411
  • 8.162E-8
  • 0.0000019
  • 2.31E-7
  • 0
  • 2.478E-8
  • 1.665E-9
  • 5.784E-9
  • -0.00005441
Eutrophication potential - marine (EP-marine)
  • 0.0007117
  • 0.00001681
  • 0.0001991
  • 0.000005809
  • 0.00001897
  • 0.000002758
  • 0
  • 0.000001764
  • 0.000001306
  • 0.000001815
  • -0.0003342
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01049
  • 0.0001873
  • 0.00225
  • 0.00006498
  • 0.0002628
  • 0.0000359
  • 0
  • 0.00001973
  • 0.00001412
  • 0.00001078
  • -0.005168
Photochemical Ozone Creation Potential (POCP)
  • 0.00268
  • 0.0000527
  • 0.0006029
  • 0.00002489
  • 0.00006801
  • 0.000009655
  • 0
  • 0.000007558
  • 0.000003381
  • 0.000003228
  • -0.001404
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.826E-8
  • 1.556E-9
  • 1.697E-8
  • 2.314E-9
  • 8.02E-10
  • 2.2E-10
  • 0
  • 7.03E-10
  • 1.7E-11
  • 9.8E-11
  • -0.00008922
Water (user) deprivation potential (WDP)
  • 17.26
  • 0.08115
  • -81.91
  • 0.1494
  • -1.283
  • 7.643
  • 0
  • 0.04536
  • 0.003218
  • 0.1753
  • 2.409

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01492
  • 0.0004417
  • 0.03881
  • 0.0006751
  • 0.001103
  • 0.0007954
  • 0
  • 0.000205
  • 0.000002401
  • 0.00005
  • -0.0006443
Potential incidence of disease due to PM emissions (PM) 2
  • 2.936E-8
  • 3.21E-10
  • 3.225E-9
  • 6.25E-10
  • 6.8E-10
  • 1.8E-10
  • 0
  • 1.9E-10
  • 1.1E-11
  • 4.8E-11
  • -1.672E-8
Potential Soil quality index (SQP) 2
  • 2.57
  • 0.05845
  • 0.7751
  • 0.108
  • 0.07137
  • 0.02208
  • 0
  • 0.03281
  • 0.0001724
  • 0.01731
  • -1.058
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.769E-7
  • 6.5E-11
  • 2.612E-9
  • 1.25E-10
  • 3.6E-9
  • 2.25E-10
  • 0
  • 3.8E-11
  • 1.8E-11
  • 1E-11
  • -8.975E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.321E-9
  • 0
  • 7.7E-11
  • 0
  • 4.8E-11
  • 1E-11
  • 0
  • 0
  • 0
  • 1E-12
  • -1.047E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 129.6
  • 0.07169
  • 2.989
  • 0.1145
  • 2.888
  • 0.1997
  • 0
  • 0.03477
  • 0.004242
  • 11.55
  • -74.22