| Key Data Set Information | |
| Location | DE |
| Geographical representativeness description | Europe. |
| Reference year | 2024 |
| Name |
|
| Technical purpose of product or process | For diverse applications. Nominal sizes 200 x 100 - 1500 x 800 mm, can be ordered in increments of 1 mm. For more informations see: https://www.trox.de/en/fire-dampers/fk2-eu-6a7ebbadc72c1037 Fire damper that meets the requirements of the European product standard EN 15650, square or rectangular, with two large inspection accesses that can be opened without tools. Tested for fire resistance properties to EN 1366-2 (negative pressure of 300 Pa and 500 Pa), with CE marking. The fire damper manufacturer's declaration of performance (DoP) provides proof that a product is suitable for the respective installation conditions, e. g. in, on the face of and remote from walls or ceilings, with the stated essential characteristics such as size, supporting construction, construction and installation type, and that it has the corresponding class of performance to EN 13501-3. The ready-for-operation unit includes a release mechanism and a replaceable, fire-resistant damper blade, which, depending on the application, can be either horizontal or vertical. Classification (depending on application): EI 30 (ve, ho i <-> o) S to EI 240 (ve, ho i <-> o) S. This EPD includes the environmental data of the product series FK2-EU. The following represents a representative dataset of the most sold variant in the declared sales year (FK2-EU/200x200x500/Z43). |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-01-02" - "2029-01-02" |
| Technological representativeness | |
| Technology description including background system | Nominal sizes (4): 200 × 100 – 1500 × 800 mm. Casing lengths: 305 and 500 mm. Volume flow rate range: Up to 14400 l/s or 51840 m³/h. Differential pressure range: Up to 2000 Pa. Temperature range (1, 3): -20 to 50 °C. Release temperature: 72 °C or 95 °C (for warm air ventilation systems). Upstream velocity (2): Standard construction = 8 m/s. construction with spring return actuator = 12 m/s. construction with explosion-proof actuator ExMax/RedMax-15-BF TR = 10 m/s. 1 Temperatures may differ for units with attachments. Details for other applications are available on request. 2 Data applies to uniform upstream and downstream conditions for the fire damper. 3 Condensation and the intake of humid outdoor air have to be avoided as otherwise operation will be impaired or not possible. 4 Damper blade with lip seal for sizes 1 and 2, damper blade with travel stop seal for size 3. |
| Subtype | representative dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-10-31T11:41:08 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 7eb3ff2b-5d2d-434b-9426-b6e3f5a75fb8 |
| Date of last revision | 2023-12-19T09:39:35.9867293Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-5682-4950 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle