Close Go back Collapse all sections
Process Data set: HF-Coilfix PP16/ Data cable U/UTP 6 4P awg 23 EC400 (en) en

Key Data Set Information
Location NO
Geographical representativeness description Nordic
Reference year 2025
Name
HF-Coilfix PP16/ Data cable U/UTP 6 4P awg 23 EC400
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. U/UTP cat 6 cable, unscreened, used in data communication networks with 400MHz bandwidth capacity. The cable can be used indoor, fixed installed in dry and moisty environment's, and outdoor if protected against UV. May not be buried. The cable are Halogen Free, Non Corrosive and Flame retardant, meet EN 50575 classification Dca. CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 CABLE Construction standards ISO/IEC 11801; EN 50173; IEC61156-5EN50288-1; ANS/TIA/EIA 568-C2
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min Conductor Solid copper class 1 AWG 23 Insulation - conductor PE - coloured Conductor marking/Pairs Colours Combinations "1 White-Blue / Blue; 2 White-Orange / Orange 3 White-Green / Green; 4 White-Brown / Brown" Conductor laying Varying short pair lay-length (4 pairs). Pair seperation PE cross Jacket HFFR compound TS EN 50290-2-27 Marking acc. EIA/TIA-568-C.2 Voltage - nominel Uo/U 125 Voltage - test 1000 Conductor resistance ?/km 85 Mutual capacitance / Capacitance unballance pF/m 50/1600 Resistance isulation M? x m 5000 Resistant to fire performance EN 60332-1-2 CPR EN 50575 compliance Dca DoP 17092 Temperature - operation -30 to +70°C Temperature - installation 0 - +50 °C Bending Radius Installation/operation 50/25mm

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.3295
  • 0.001616
  • 0.03316
  • 0.003259
  • 0.7061
  • 0
  • 0
  • 0.0005798
  • 0.0009296
  • -2.699
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.3295
  • 0.001616
  • 0.03316
  • 0.003259
  • 0.7061
  • 0
  • 0
  • 0.0005797
  • 0.0009296
  • -2.699
Input
  • 4.633
  • 0.1283
  • 0.1049
  • 0.2277
  • 48.91
  • 0
  • 0
  • 0.01935
  • 0.01322
  • -1.193
Input
  • 2.795
  • 0
  • 0
  • 0
  • -0.04975
  • 0
  • 0
  • -2.687
  • 0
  • -0.3023
Input
  • 7.427
  • 0.1283
  • 0.1049
  • 0.2277
  • 48.86
  • 0
  • 0
  • -2.668
  • 0.01322
  • -1.495
Input
  • 0.004169
  • 0
  • 0
  • 0
  • 0.00008723
  • 0
  • 0
  • 0
  • 0.000008987
  • 0.01349
Input
  • 0.00581
  • 0.00005541
  • 0.0006353
  • 0.0001166
  • 0.02513
  • 0
  • 0
  • 0.00001611
  • 0.00001996
  • 0.0002234
Input
  • 0.003276
  • 0.0002493
  • 0.0001179
  • 0.0004169
  • 0.08945
  • 0
  • 0
  • 0
  • 0.0006562
  • -0.1376
Input
  • 0.004264
  • 0.00001221
  • 0.0002057
  • 0.00002435
  • 0.005313
  • 0
  • 0
  • 0.00005393
  • 0.00001575
  • -0.005386
Output
  • 0.001837
  • 0.000006398
  • 0.0003685
  • 0.00001174
  • 0.002659
  • 0
  • 0
  • 0
  • 0.005192
  • -0.000559
Output
  • 0.04992
  • 0.00505
  • 0.0197
  • 0.01107
  • 2.378
  • 0
  • 0
  • 0
  • 0.04413
  • -0.03277
Output
  • 0.000006367
  • 8.777E-7
  • 1.717E-7
  • 0.000001551
  • 0.0003326
  • 0
  • 0
  • 0
  • 8.677E-8
  • -0.000002858
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.07855
  • 0
  • 0.002093
  • 0
  • 0
  • 0.0364
  • 0.000002914
  • -0.000533
Output
  • 0
  • 0
  • 0.01345
  • 0
  • 0.002126
  • 0
  • 0
  • 0.1063
  • 2.982E-7
  • -0.00009173
Output
  • 0
  • 0
  • 0.02067
  • 0
  • 0.003734
  • 0
  • 0
  • 0.1856
  • 0.000006615
  • -0.0002091
Output
  • 0
  • 0
  • 0.3127
  • 0
  • 0.05649
  • 0
  • 0
  • 2.809
  • 0.0001001
  • -0.003164

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 7.208
  • 0.1283
  • 0.1049
  • 0.2277
  • 48.96
  • 0
  • 0
  • 0.01935
  • 0.01322
  • -1.469
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0000444
  • 1.961E-7
  • 7.63E-8
  • 4.159E-7
  • 0.00009008
  • 0
  • 0
  • 1.042E-8
  • 5.147E-9
  • -0.00004385
Acidification potential, Accumulated Exceedance (AP)
  • 0.01578
  • 0.00008944
  • 0.00006162
  • 0.00004327
  • 0.009606
  • 0
  • 0
  • 0.00003643
  • 0.000004606
  • -0.008032
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.004263
  • 0.00000336
  • 0.00003088
  • 0.000006232
  • 0.001425
  • 0
  • 0
  • 0.000002372
  • 4.967E-7
  • -0.0003778
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.3031
  • 0.00882
  • 0.04051
  • 0.01506
  • 3.24
  • 0
  • 0
  • 0.2898
  • 0.004137
  • -0.09206
Global Warming Potential - total (GWP-total)
  • 0.3075
  • 0.008826
  • 0.04061
  • 0.01507
  • 3.243
  • 0
  • 0
  • 0.2898
  • 0.004137
  • -0.09341
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0001732
  • 0.000003989
  • 0.00006973
  • 0.000005359
  • 0.001154
  • 0
  • 0
  • 3.567E-7
  • 1.703E-7
  • -0.0009779
  • 0.2979
  • 0.008826
  • 0.04054
  • 0.01507
  • 3.242
  • 0
  • 0
  • 0.2898
  • 0.004175
  • -0.06733
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001518
  • 6.198E-8
  • 8.441E-7
  • 1.203E-7
  • 0.00002895
  • 0
  • 0
  • 2.344E-8
  • 9.987E-9
  • -0.00005486
Eutrophication potential - marine (EP-marine)
  • 0.0005932
  • 0.00002059
  • 0.00001127
  • 0.000008562
  • 0.001849
  • 0
  • 0
  • 0.00001745
  • 0.000005434
  • -0.0004013
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.008233
  • 0.0002294
  • 0.0001238
  • 0.00009577
  • 0.02071
  • 0
  • 0
  • 0.0001888
  • 0.0000179
  • -0.005836
Photochemical Ozone Creation Potential (POCP)
  • 0.002769
  • 0.00006501
  • 0.00003334
  • 0.00003669
  • 0.007925
  • 0
  • 0
  • 0.00004532
  • 0.00000584
  • -0.001613
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.155E-8
  • 2.034E-9
  • 5.81E-10
  • 3.411E-9
  • 7.314E-7
  • 0
  • 0
  • 2.25E-10
  • 1.69E-10
  • -0.001948
Water (user) deprivation potential (WDP)
  • 4.943
  • 0.101
  • -0.8985
  • 0.2202
  • 47.29
  • 0
  • 0
  • 0.04451
  • 0.1702
  • -4.983

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.006786
  • 0.0005582
  • 0.0001612
  • 0.0009951
  • 0.2135
  • 0
  • 0
  • 0.00003329
  • 0.00006931
  • -0.003509
Potential incidence of disease due to PM emissions (PM) 2
  • 3.175E-8
  • 4.08E-10
  • 3.35E-10
  • 9.22E-10
  • 1.983E-7
  • 0
  • 0
  • 1.59E-10
  • 7.9E-11
  • -2.943E-8
Potential Soil quality index (SQP) 2
  • 1.641
  • 0.07512
  • 0.02075
  • 0.1592
  • 34.17
  • 0
  • 0
  • 0.002403
  • 0.04106
  • -3.483
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.476E-7
  • 8E-11
  • 1.87E-10
  • 1.84E-10
  • 4.465E-8
  • 0
  • 0
  • 2.45E-10
  • 2E-11
  • -8.829E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.806E-9
  • 0
  • 4E-12
  • 0
  • 5.8E-11
  • 0
  • 0
  • 7E-12
  • 0
  • -1.049E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 116.3
  • 0.09059
  • 0.1697
  • 0.1688
  • 38.7
  • 0
  • 0
  • 0.05746
  • 5.586
  • -73.42