Close Go back Collapse all sections
Process Data set: AXQJ-TT Pure TSLI 24kV AL 1x500/35mm² AFR (en) en

Key Data Set Information
Location SE
Geographical representativeness description Norway
Reference year 2024
Name
AXQJ-TT Pure TSLI 24kV AL 1x500/35mm² AFR
Technical purpose of product or process AXQJ-TT Pure TSLI 24KV AL Halogen free and flame retardant on fire. Smoke generation at fire is small, low smoke density (makes evacuation easier) and is not harmful to electrical equipment. Distribution cable for indoor use in 3-phase installation. Can be placed in pipes and in the ground.The cable is axially and radially waterproof. Conductor material Aluminium Conductor surface Bare Longitudinal water blocking conductors Yes Inner semi-conducting layer Yes Core insulation material XLPE Outer semi-conducting layer Yes Drain wire Yes Longitudinal water blocking cable Yes Radial water blocking cable Yes Screen construction Aluminium tape and copper wire Screen Yes Screen material Copper, bare Concentric conductor Copper Material inner sheath Other Material outer sheath Halogenfree polymer Laminated sheath Yes Longitudinal water blocking screen Yes Protective barrier Al/PE Cable shape Round
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-09-06 - 2029-09-06
Technological representativeness
Technology description including background system AXQJ-TT Pure TSLI 24KV AL 1x500/35mm² AFR SAP code: 20217598 El nr. 1060212 STANDARDS APPLIED: HD 620 Part 10, Section K and M, HD604 (halogen-free sheath) Design standard IEC 60332-3-24 (Cat. C) Flame retardant EN 60754-1 and EN 60754-2 Halogen free properties: EN 60754-1 (pH = 4,3, Conductivity = 10µS), EN 60754-2 ( < 0,5% Halogen) Low smoke IEC 61034

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 61.34
  • 0.1262
  • 6.564
  • 0.03807
  • 1.363
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.08839
  • 0
  • 0
  • 0.02937
  • 0.006882
  • 0.02936
  • -38.64
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 61.34
  • 0.1262
  • 6.564
  • 0.03807
  • 1.363
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.08839
  • 0
  • 0
  • 0.02937
  • 0.006882
  • 0.02936
  • -38.64
Input
  • 356.3
  • 7.612
  • 13.87
  • 3.024
  • 7.667
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.006834
  • 0
  • 0
  • 2.082
  • 0.153
  • 0.3045
  • -85.7
Input
  • 37.34
  • 0
  • 0
  • 0
  • 0.05363
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -34.66
  • 0
  • 0
Input
  • 393.6
  • 7.612
  • 13.87
  • 3.024
  • 7.72
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.006834
  • 0
  • 0
  • 2.082
  • -34.51
  • 0.3045
  • -85.7
Input
  • 0.2796
  • 0
  • 0
  • 0
  • 0.005591
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01123
Input
  • 0.3964
  • 0.003507
  • 0.02576
  • 0.001332
  • 0.008577
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00006941
  • 0
  • 0
  • 0.001051
  • 0.00016
  • 0.0006099
  • -0.01277
Input
  • 0.1408
  • 0.02013
  • 0.08294
  • 0.004463
  • 0.00507
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001729
  • 0
  • 0
  • 0.003753
  • 0
  • 0.001378
  • -0.4304
Input
  • 0.4911
  • 0.0009639
  • 0.01605
  • 0.0003444
  • 0.0102
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0006602
  • 0
  • 0
  • 0.0002192
  • 0.0009435
  • 0.0003882
  • -0.1769
Output
  • 0.2295
  • 0.0004893
  • 0.06625
  • 0.0001656
  • 0.006491
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000004382
  • 0
  • 0
  • 0.0001062
  • 0
  • 0.02804
  • 0.02737
Output
  • 6.491
  • 0.4349
  • 0.101
  • 0.2631
  • 0.1697
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005257
  • 0
  • 0
  • 0.09949
  • 0
  • 1.097
  • -1.97
Output
  • 0.0009023
  • 0.00005079
  • 0.0002063
  • 0.00002065
  • 0.00002392
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.111E-8
  • 0
  • 0
  • 0.00001419
  • 0
  • 0.000002069
  • -0.0003509
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.004362
  • 0
  • 0.02166
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.079
  • 0.00005329
  • -0.0004393
Output
  • 0
  • 0
  • 0.2483
  • 0
  • 0.01685
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5941
  • 0.000001303
  • -0.00005784
Output
  • 0
  • 0
  • 0.1446
  • 0
  • 0.02369
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.04
  • 0.00008455
  • -0.0001417
Output
  • 0
  • 0
  • 2.187
  • 0
  • 0.3583
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 15.73
  • 0.001279
  • -0.002144

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 391.1
  • 7.612
  • 13.84
  • 3.024
  • 8.362
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.006824
  • 0
  • 0
  • 2.081
  • 0.153
  • 0.3045
  • -85.7
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0008887
  • 0.000006995
  • 0.000004899
  • 0.00000332
  • 0.00001816
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.728E-8
  • 0
  • 0
  • 0.000003739
  • 1.055E-7
  • 1.02E-7
  • -0.00002683
Acidification potential, Accumulated Exceedance (AP)
  • 0.2453
  • 0.004716
  • 0.0008837
  • 0.0008173
  • 0.005052
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000003906
  • 0
  • 0
  • 0.0005643
  • 0.0002638
  • 0.0001029
  • -0.05196
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.2714
  • 0.0002429
  • 0.03037
  • 0.0000798
  • 0.006044
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001382
  • 0
  • 0
  • 0.00005628
  • 0.00002203
  • 0.000006385
  • -0.03075
Global Warming Potential - fossil fuels (GWP-fossil)
  • 33.09
  • 0.5245
  • 0.2633
  • 0.1944
  • 0.718
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004999
  • 0
  • 0
  • 0.138
  • 1.611
  • 0.07552
  • -6.739
Global Warming Potential - total (GWP-total)
  • 33.55
  • 0.525
  • 0.3012
  • 0.1946
  • 0.728
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005158
  • 0
  • 0
  • 0.1381
  • 1.611
  • 0.07553
  • -6.898
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.19
  • 0.0002137
  • 0.007569
  • 0.00005676
  • 0.003959
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000002062
  • 0
  • 0
  • 0.00004825
  • 0.000003806
  • 0.00000416
  • -0.1288
  • 33.46
  • 0.525
  • 0.2948
  • 0.1946
  • 0.7261
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005148
  • 0
  • 0
  • 0.1381
  • 1.611
  • 0.07776
  • -6.568
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001507
  • 0.000004905
  • 0.000008608
  • 0.000001483
  • 0.00003048
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.596E-8
  • 0
  • 0
  • 0.000001084
  • 2.002E-7
  • 1.972E-7
  • -0.0003071
Eutrophication potential - marine (EP-marine)
  • 0.03295
  • 0.001537
  • 0.0002191
  • 0.0002457
  • 0.000707
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.293E-7
  • 0
  • 0
  • 0.0001673
  • 0.0001264
  • 0.0001073
  • -0.006158
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.374
  • 0.01696
  • 0.002169
  • 0.002718
  • 0.007989
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005588
  • 0
  • 0
  • 0.001851
  • 0.001327
  • 0.0004114
  • -0.06892
Photochemical Ozone Creation Potential (POCP)
  • 0.1133
  • 0.004744
  • 0.0005232
  • 0.0008739
  • 0.002409
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000001503
  • 0
  • 0
  • 0.0005667
  • 0.000319
  • 0.0001311
  • -0.02281
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001692
  • 1.115E-7
  • 6.049E-8
  • 4.493E-8
  • 3.892E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.4E-11
  • 0
  • 0
  • 3.147E-8
  • 2.164E-9
  • 3.888E-9
  • -0.006644
Water (user) deprivation potential (WDP)
  • 5553
  • 5.592
  • 1382
  • 2.32
  • 139
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.19
  • 0
  • 0
  • 1.986
  • 0.796
  • 5.418
  • -3803

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.918
  • 0.03276
  • 0.4672
  • 0.01322
  • 0.02885
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001238
  • 0
  • 0
  • 0.009099
  • 0.0003335
  • 0.001775
  • -0.3745
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000002346
  • 4.422E-8
  • 6.919E-9
  • 1.712E-8
  • 4.854E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.8E-11
  • 0
  • 0
  • 9.938E-9
  • 1.099E-9
  • 1.902E-9
  • -5.202E-7
Potential Soil quality index (SQP) 2
  • 72.26
  • 6.79
  • 6.244
  • 3.469
  • 1.821
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003437
  • 0
  • 0
  • 1.435
  • 0.02412
  • 0.8138
  • -10.19
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001526
  • 6.314E-9
  • 6.477E-9
  • 2.139E-9
  • 3.091E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.5E-11
  • 0
  • 0
  • 1.656E-9
  • 2.539E-9
  • 3.69E-10
  • -2.735E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.844E-8
  • 0
  • 2.67E-10
  • 0
  • 1.176E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1E-12
  • 0
  • 0
  • 0
  • 6E-11
  • 1.8E-11
  • -1.77E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1356
  • 5.985
  • 8.192
  • 2.212
  • 33.58
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03109
  • 0
  • 0
  • 1.533
  • 1.581
  • 303.6
  • -166.2