Close Go back Collapse all sections
Process Data set: Roth QuickBox®-red (en) en

Key Data Set Information
Location DK
Geographical representativeness description Denmark, Sweden, Norway, Finland & UK
Reference year 2024
Name
Roth QuickBox®-red
Use advice for data set Module A1: Packaging has been included by average use of packaging pr. 1 kg of product. Module A4: The transportation distances provided in this EPD are derived from precise data concerning the distances between production facility and and various sales departments in different countries. Subsequently, it is assumed that the distribution from each of these sales departments to the end customers an approximate distance of 300 km*. *Transportation by truck is assumed on a distributon of 80% EURO 6 and 20% EURO 5, based on data from the companys own logistics provider. Module C2: The estimated transportion distance to the waste handling facility in this EPD is 100 km, assuming the use of a truck as the transport method.
Technical purpose of product or process Roth QuickBox®-red is developed to meet today’s requirements for corrosion-resistant installations. Roth QuickBox®-red can be used for wall or panel wall (additional accessories required) for 15 mm PEX pipes in a 25 mm corrugated pipe. Roth QuickBox®-red is made of transparent, molded plastic with a pre-mounted red brass elbow and pressure testing plug. The pre-mounted sealing nipple and lock are approved according to NT VVS 129 and meets the requirements of the SBI 252 guidelines. Roth’s QuickBox®-red is delivered as a single box with a push-fit coupling for 15 mm. The push-fit coupling ensures a quick and secure connection. Armaturfix can be used where a double box for the wall is desired.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-16 - 2029-12-16
Technological representativeness
Technology description including background system The plastic housing is molded in transparent polycarbonate (PC). The sealing nipple is made of glass fiber reinforced PP with lips of TPR. The lock for the corrugated pipe is made of GF reinforced ABS. The gasket for the elbow is made of EPDM rubber. The push-fit elbow is made of red brass with a ½” internal thread. The integrated locking ring in the elbow is made of stainless steel, the O-ring is made of EPDM rubber, and the release ring and support ring are made of acetal plastic. The included liner is made of stainless steel AISI/SUS 316.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 4.163
  • 0.05481
  • 0.0005082
  • 0
  • 0.003868
  • 0.007074
  • 0.0001766
  • -4.535
Input
  • 0.4338
  • 0
  • -0.4338
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 4.597
  • 0.05481
  • -0.4333
  • 0
  • 0.003868
  • 0.007074
  • 0.0001766
  • -4.535
Input
  • 81.39
  • 5.334
  • 0.02429
  • 0
  • 0.2741
  • 0.1278
  • 0.01561
  • -0.1061
Input
  • 12.73
  • 0
  • -1.602
  • 0
  • 0
  • -11.13
  • 0
  • 0
Input
  • 94.12
  • 5.334
  • -1.578
  • 0
  • 0.2741
  • -11
  • 0.01561
  • -0.1061
Input
  • 0.5599
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000003547
  • 0.005542
Input
  • 0.028
  • 0.00181
  • 0.0000147
  • 0
  • 0.0001385
  • 0.0001523
  • 0.00001062
  • 0.001591
Input
  • 0.06236
  • 0.01131
  • 0.00004831
  • 0
  • 0.0004943
  • 0
  • 0.00009763
  • -0.2569
Input
  • 0.04738
  • 0.0004135
  • 0.00001216
  • 0
  • 0.00002887
  • 0.001072
  • 0.00001801
  • -0.004045
Output
  • 0.02806
  • 0.0002492
  • 0
  • 0
  • 0.00001398
  • 0
  • 0.0006797
  • 0.0005721
Output
  • 1.068
  • 0.1156
  • 0.09063
  • 0
  • 0.0131
  • 0
  • 0.06104
  • -0.001884
Output
  • 0.0002302
  • 0.00003675
  • 0
  • 0
  • 0.000001869
  • 0
  • 9.617E-8
  • -0.000001057
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.4643
  • 0
  • 0.06846
  • 0
  • 0
  • 0.5435
  • 0.000003161
  • 0.0007461
Output
  • 0.00128
  • 0
  • 0.0037
  • 0
  • 0
  • 0.3961
  • 9.773E-8
  • 0.00009
Output
  • 0.002614
  • 0
  • 0.003029
  • 0
  • 0
  • 0.6117
  • 3.003E-7
  • 0.0005664
Output
  • 0.03955
  • 0
  • 0.04582
  • 0
  • 0
  • 9.255
  • 0.000004543
  • 0.00857

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 94.08
  • 5.334
  • 0.02429
  • 0
  • 0.2741
  • 0.1278
  • 0.01561
  • -0.1068
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001615
  • 0.000005875
  • 3.673E-8
  • 0
  • 4.924E-7
  • 1.013E-7
  • 5.532E-9
  • 0.0004381
Acidification potential, Accumulated Exceedance (AP)
  • 0.05937
  • 0.008162
  • 0.000007736
  • 0
  • 0.00007431
  • 0.0002041
  • 0.000004512
  • 0.00628
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.07283
  • 0.000132
  • 0.08981
  • 0
  • 0.000007412
  • 0.00002019
  • 5.859E-7
  • 0.0002864
Global Warming Potential - fossil fuels (GWP-fossil)
  • 7.669
  • 0.3904
  • 0.003844
  • 0
  • 0.01818
  • 0.9447
  • 0.0005479
  • -0.00206
Global Warming Potential - total (GWP-total)
  • 7.599
  • 0.3905
  • 0.09365
  • 0
  • 0.01819
  • 0.9447
  • 0.0005486
  • -0.003514
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.002792
  • 0.0002297
  • 5.122E-7
  • 0
  • 0.000006355
  • 0.000003753
  • 1.679E-7
  • -0.001741
  • 7.671
  • 0.3905
  • 0.003844
  • 0
  • 0.01819
  • 0.9446
  • 0.001655
  • -0.0137
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0006047
  • 0.000002251
  • 1.318E-8
  • 0
  • 1.428E-7
  • 1.79E-7
  • 8.02E-9
  • 0.00004878
Eutrophication potential - marine (EP-marine)
  • 0.007631
  • 0.002016
  • 0.00000471
  • 0
  • 0.00002204
  • 0.00009756
  • 0.000001366
  • 0.0001748
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.09089
  • 0.02243
  • 0.00002771
  • 0
  • 0.0002437
  • 0.001001
  • 0.00001514
  • 0.003259
Photochemical Ozone Creation Potential (POCP)
  • 0.02729
  • 0.005925
  • 0.000008513
  • 0
  • 0.00007462
  • 0.0002413
  • 0.000004568
  • 0.0007992
Depletion potential of the stratospheric ozone layer (ODP)
  • 5.012E-7
  • 8.47E-8
  • 3.6E-10
  • 0
  • 4.144E-9
  • 2.014E-9
  • 2.21E-10
  • -0.003909
Water (user) deprivation potential (WDP)
  • 28.16
  • 2.927
  • 0.05872
  • 0
  • 0.2615
  • 0.9141
  • 0.01223
  • -7.813

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.1787
  • 0.02309
  • 0.0001069
  • 0
  • 0.001198
  • 0.0003202
  • 0.00006267
  • -0.001304
Potential incidence of disease due to PM emissions (PM) 2
  • 5.055E-7
  • 9.699E-9
  • 1.26E-10
  • 0
  • 1.309E-9
  • 8.92E-10
  • 7.3E-11
  • -1.368E-8
Potential Soil quality index (SQP) 2
  • 19.65
  • 2.042
  • 0.02954
  • 0
  • 0.189
  • 0.02323
  • 0.05794
  • -4.345
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 5.537E-7
  • 1.802E-9
  • 3.1E-11
  • 0
  • 2.18E-10
  • 2.433E-9
  • 9.144E-8
  • 7.778E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.035E-8
  • 0
  • 0
  • 0
  • 0
  • 5.4E-11
  • 1.333E-9
  • 8.15E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 554
  • 3.475
  • 0.02772
  • 0
  • 0.2019
  • 1.944
  • 0.4706
  • 60.58