Close Go back Collapse all sections
Process Data set: TVE-Q (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe.
Reference year 2024
Name
TVE-Q
Use advice for data set A1 includes the extraction and production of all raw materials used in the product. A2 includes all types of transportation methods used for the raw materials to the production site in Anholt, Germany. A3 includes the manufacturing and packaging process of the air handling unit. A4 includes the transport to the market/user. A5 modules not declared. B1 - B5 No emissions are released during use of the product (B1). Maintenance (B2) and repair (B3) or replacement of individual components (B4) is not relevant during the service life under consideration (maintenance-free). According to the manufacturer, the product does not need to be replaced during its service life (B5). The modules are therefore labelled with ‘0’. B6 - B7 During operation of the building, electrical energy is required to supply the electric drive motor and setpoint adjustments of the product. C1 - C4 includes the use of energy and other auxiliary materials required to demolish the building or construction in which the product is included, transport from the building site to the waste processing facility, distribution of the product to different waste treatment methods and the disposal. D includes energy and materials that have achieved a new function and are no longer considered waste.
Technical purpose of product or process Compact solution for low airflow velocities. Angular air terminal units for use in variable air terminal systems at low air velocities, even under unfavourable upstream conditions. For more information see: www.trox.de/en/428f30783cd80fe1. VAV terminal units in rectangular design for variable and constant volume flow systems, for supply air or extract air, in several nominal sizeGs. High control accuracy of set volume flow rates, even in unfavourable upstream conditions. Control range at least 1:10. Differential pressure measurement and control via damper blade. Tubeless differential pressure transmission through differential pressure duct in axis Air leakage with closed damper blade according to EN 1751: Class 3. Casing air leakage according to EN 1751: Class C. Ready-to-commission unit which consists of the mechanical parts and the factory mounted electronic control component. Position of the damper blade indicated externally at the control component The damper blade is factory set to open position, which allows a ventilation airflow even without control. Meets the hygiene requirements of EN 16798, Part 3, of VDI 6022, Sheet 1, and of DIN 1964, Part 4. This EPD includes the environmental data of the product series TVE-Q. The following represents a representative dataset of the most sold variant in the declared sales year (TVE-Q/300x200/EASY).
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 2.25080952E-4 kg
  • Carbon content (biogenic) - packaging: 2.378366176476 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-11-19" - "2029-11-19"
Technological representativeness
Technology description including background system Nominal sizes: 200 × 100, 300 × 100, 200 × 200, 300 × 200, 400 × 200, 500 × 200, 600 × 200. Volume flow rate range: 16 - 960 l/s or 58 - 3456 m³/h. Volume flow rate control range (controller with dynamic differential pressure measurements): approx. 10 - 100 % of the nominal volume flow rate. Minimum differential pressure: up to 50 Pa (without secondary silencer). Maximum differential pressure: Control component with dynamic transducer: 900 Pa, Control component with static transducer: 600 Pa. Operating temperature: 10 to 50 °C. For more technical data see: www.trox.de/en/428f30783cd80fe1. The distribution of materials in the products is approximately the same; only the total weight varies. The EPD is created for TVE-Q/300x200. The factors in the table below can be used to scale LCA data for a new dimension.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 119.2
  • 0.3182
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2706
  • 0
  • 0.0005644
  • 0.01989
  • 0.02236
  • 0.01953
  • -3.161
Input
  • 67.95
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 187.2
  • 0.3182
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2706
  • 0
  • 0.0005644
  • 0.01989
  • 0.02236
  • 0.01953
  • -3.161
Input
  • 673.8
  • 22.23
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.399E+4
  • 0
  • 0.1044
  • 1.389
  • 0.3236
  • 0.3135
  • -15.86
Input
  • 2.091
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 675.7
  • 22.23
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.399E+4
  • 0
  • 0.1044
  • 1.389
  • 0.3236
  • 0.3135
  • -15.86
Input
  • 4.524
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005124
  • 0
  • 0
  • 0.000003935
  • 0
Input
  • 2.864
  • 0.01138
  • 0
  • 0
  • 0
  • 0
  • 0
  • 197.3
  • 0
  • 0.00001389
  • 0.0007115
  • 0.0005453
  • 0.0004641
  • 0.04058
Input
  • 9.819
  • 0.0407
  • 0
  • 0
  • 0
  • 0
  • 0
  • 46.87
  • 0
  • 0.0002043
  • 0.002544
  • -0.0003876
  • 0.0001345
  • 1.203
Input
  • 0.5799
  • 0.002377
  • 0
  • 0
  • 0
  • 0
  • 0
  • 11.86
  • 0
  • 0.000005371
  • 0.0001486
  • 0.001492
  • 0.001217
  • -0.01478
Output
  • 0.4315
  • 0.001146
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.103
  • 0
  • 0.000003072
  • 0.00007165
  • 0.00206
  • 0.01368
  • -0.003933
Output
  • 12.34
  • 1.081
  • 0
  • 0
  • 0
  • 0
  • 0
  • 47.31
  • 0
  • 0.0001236
  • 0.06756
  • 0.294
  • 0.8399
  • -0.6114
Output
  • 0.002383
  • 0.0001514
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.09985
  • 0
  • 7.246E-7
  • 0.000009464
  • 0.00000118
  • 0.000001125
  • -0.00002216
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.7526
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005032
  • 0
  • 4.556
  • 0.000003215
  • 0
Output
  • 0.2441
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.56E-7
  • 0
  • 0.01432
  • 7.862E-8
  • 0
Output
  • 0.1439
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.349E-7
  • 0
  • 0.3673
  • 0.0000051
  • 0
Output
  • 2.177
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000008092
  • 0
  • 5.557
  • 0.00007716
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 674.9
  • 22.23
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.397E+4
  • 0
  • 0.1044
  • 1.389
  • 0.3236
  • 0.3135
  • -15.87
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.03092
  • 0.00004061
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004963
  • 0
  • 1.163E-8
  • 0.000002538
  • 2.918E-7
  • 2.534E-7
  • -0.00001911
Acidification potential, Accumulated Exceedance (AP)
  • 0.4422
  • 0.004225
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.952
  • 0
  • 0.00007931
  • 0.0002641
  • 0.0002565
  • 0.0001189
  • -0.009012
Global Warming Potential - biogenic (GWP-biogenic)
  • -8.137
  • 0.0006085
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.759
  • 0
  • 0.000001421
  • 0.00003803
  • 0.00009727
  • 0.00008157
  • -0.002867
Global Warming Potential - fossil fuels (GWP-fossil)
  • 50.41
  • 1.47
  • 0
  • 0
  • 0
  • 0
  • 0
  • 676.8
  • 0
  • 0.007582
  • 0.09188
  • 0.7495
  • 0.05807
  • -1.636
Global Warming Potential - total (GWP-total)
  • 42.37
  • 1.471
  • 0
  • 0
  • 0
  • 0
  • 0
  • 683.1
  • 0
  • 0.007584
  • 0.09195
  • 0.7496
  • 0.05817
  • -1.649
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.09129
  • 0.0005232
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.574
  • 0
  • 5.976E-7
  • 0.0000327
  • 0.00002272
  • 0.00002049
  • -0.009783
  • 51.11
  • 1.471
  • 0
  • 0
  • 0
  • 0
  • 0
  • 732.9
  • 0
  • 0.007584
  • 0.09195
  • 0.7495
  • 0.05194
  • -2.197
Eutrophication potential - freshwater (EP-freshwater)
  • 0.006193
  • 0.00001175
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07227
  • 0
  • 2.76E-8
  • 7.341E-7
  • 8.259E-7
  • 6.581E-7
  • -0.00008965
Eutrophication potential - marine (EP-marine)
  • 0.06256
  • 0.000836
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5016
  • 0
  • 0.00003501
  • 0.00005225
  • 0.0001066
  • 0.00003645
  • -0.001601
Eutrophication potential - terrestrial (EP-terrestrial)
  • 1.159
  • 0.009351
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.183
  • 0
  • 0.0003841
  • 0.0005844
  • 0.00109
  • 0.0003577
  • -0.01669
Photochemical Ozone Creation Potential (POCP)
  • 0.2078
  • 0.003582
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.568
  • 0
  • 0.0001056
  • 0.0002239
  • 0.0002694
  • 0.0001004
  • -0.007311
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000004422
  • 3.33E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005732
  • 0
  • 1.639E-9
  • 2.081E-8
  • 3.796E-9
  • 3.476E-9
  • -0.0001178
Water (user) deprivation potential (WDP)
  • 3083
  • 21.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.1E+5
  • 0
  • 0.02217
  • 1.344
  • 0.9434
  • 0.9478
  • -218.6

IndicatorUnit Production
A1-A3
Transport
A4
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 2.794
  • 0.09715
  • 0
  • 0
  • 0
  • 0
  • 0
  • 122.3
  • 0
  • 0.0004472
  • 0.006072
  • 0.001191
  • 0.001366
  • -0.02285
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000003858
  • 9E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001036
  • 0
  • 2.099E-9
  • 5.625E-9
  • 1.569E-9
  • 1.472E-9
  • -1.301E-7
Potential Soil quality index (SQP) 2
  • 982.5
  • 15.55
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3372
  • 0
  • 0.01324
  • 0.9717
  • 0.1184
  • 0.4039
  • -0.9309
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002844
  • 1.8E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000009423
  • 0
  • 5.2E-11
  • 1.125E-9
  • 5.505E-9
  • 5.47E-10
  • 1.058E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.602E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.729E-7
  • 0
  • 0
  • 0
  • 6.1E-11
  • 1.1E-11
  • -6.761E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 3298
  • 16.48
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9783
  • 0
  • 0.05703
  • 1.03
  • 2.161
  • 4.192
  • -71.54