| Key Data Set Information | |
| Location | FR |
| Geographical representativeness description | Norway |
| Reference year | 2025 |
| Name |
|
| Technical purpose of product or process | 1131721 ÖLFLEX CLASSIC 100 300/500V cables are colour coded control cables for occasional flexible use and fixed installation for medium mechanical use. They are suitable for use in dry, damp and wet areas and are space-saving due to smaller cable diameters. If using outdoors, observe the indicated temperature range and use with UV protection. They are largely resistant to acids, alkalis and certain oils at room temperature. ÖLFLEX CLASSIC 100 300/500V cables are suitable for occasional, non-automated movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. Application range: ÖLFLEX CLASSIC 100 300/500V cables are used as control cable in industrial machinery, plant engineering, in power stations, in heating and air-conditioning systems, etc. This cable is suitable for torsion application in wind turbines (WTG). The torsional load is limited to applications, as they typically occur in the loop of a wind turbine. Design based on EN 50525-2-11 EN 50525-2-51 and IEC 60227-5 Certification EN 13501-6 and EN 50575 Classification of fire behaviour (article/dimension range see www.lappkabel.com/cpr) Conductor fine wire strands of bare copper acc. to IEC 60228 resp. EN 60228, class 5 Insulation PVC compound TI2 acc. to EN 50363-3 with increased requirements acc. to Lapp specification Core identification code acc. to. VDE 0293-1, with or without GN/YE ground conductor up to 5 cores: acc. to HD 308 S2 from 6 cores: acc. to LAPP ÖLFLEX color code Stranding cores are stranded in layers Outer sheath PVC compound TM2 acc. to EN 50363-4-1 with increased requirements acc. to LAPP specification colour: silver grey, similar RAL 7001 |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-07-28 - 2030-07-28 |
| Technological representativeness | |
| Technology description including background system | Electrical properties at 20 °C Specific volume resistivity > 20 G O x cm Nominal voltage U0/ U: 300 / 500 V Test voltage core/core: 4000 V AC Mechanical and thermal properties Minimum bending radius occasional flexing:15 x outer diameter fixed installation: 4 x outer diameter Temperature range occasional flexing: - 5°C up to +70°C max. conductor temp. fixed installation: - 40°C up to +80°C max. conductor temp. Torsional stress Torsion movement in wind turbine generators TW-0 (5000 cycles at =+5 °C) TW-1 (2000 cycles at =-20 °C) ±150 °/m at 1 revolution per minute Flammability flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 Tests acc. to IEC 60811 resp. EN 60811, EN 50395, EN 50396 General requirements These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive). A part of these cables (see www.lappkabel.com/cpr) are classified in accordance with the EU-Regulation no. 305/2011 (CPR). Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS). |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-08-26T20:57:58 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 5e9d5770-8e83-4af8-b2ba-6231fc3ec67e |
| Date of last revision | 2025-07-28T08:06:56.7538945Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-11906-11873 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle