| Key Data Set Information | |
| Location | DE |
| Geographical representativeness description | Europe |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | The User Stage (B1-B7) has not been considered for the product, as this stage typically involve no related actions. |
| Technical purpose of product or process | The ROKU® V2 cardboard-coated gypsum board is a fire-resistant panel made from natural gypsum. It is coated in cardboard and includes minimal additional amounts of starch, surfactants, glass fibre and mineral fillers for an improved duration of fire resistance. ROKU® V2 Gypsum Fiber Board is ideally suited for surface insulation in fire protection systems and for insulating tubular frame constructions. Classified as A2 in accordance with EN 13501-1, ROKU® V2 is engineered for use in a wide range of passive fire protection applications, including surface insulation and tubular frame construction. Within the EU and EFTA, the product falls under the scope of Regulation (EU) No 305/2011 (Construction Products Regulation, CPR) with regard to market placement. The ROKU V2 fire protection board is covered by the harmonised European standard EN 520 (Gypsum plasterboards – Definitions, requirements and test methods). The Declaration of Performance (DoP) and CE marking are provided in accordance with this standard. A European Technical Assessment (ETA) is not required for this product. The manufacture of ROKU® V2 Gypsum Fiber Board is optimized for efficiency and continuous improvement, certified to ISO 9001. Preliminary products undergo incoming inspection before use. Each batch is subject to internal quality control to ensure compliance with fire protection standards, supplemented by regular external monitoring. Raw materials are stored securely to prevent environmental release. Worker safety is prioritized with minimal direct contact with raw materials, protective clothing, dust masks, and adequate extraction systems. Waste is sorted, stored, and returned to the recycling process wherever possible. ROKU® V2 Gypsum Fiber Board is available in varying thicknesses and dimensions, including lengths of 2500 mm and widths of 1200 mm and 1250 mm. The following waste codes should be taken into account: 17 08 02 - gypsum-based construction materials other than those mentioned in 17 08 01. 100% of the known ingredients of the product have been considered in the environmental footprint calculation. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included when specific information are missing. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-10-13 - 2030-10-13 |
| Technological representativeness | |
| Technology description including background system | ROKU® V2 Gypsum Fiber Board is an asbestos-free and formaldehyde-free, cardboard-coated gypsum board made from starch, surfactants, textile glass fibers, and inorganic fillers. For further details, please refer to the product’s Technical Data Sheet (TDS). |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-10-13T17:55:32 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 5df2e084-5dce-4f1f-b578-9067fca6a141 |
| Date of last revision | 2025-08-25T13:46:26.3154468Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-12166-12178 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle