Close Go back Collapse all sections
Process Data set: mTouch One (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norway.
Reference year 2025
Name
mTouch One
Technical purpose of product or process Thermostat/Regulator, 16A/2300VA 2P mTouch® One shows the precise temperature/power on LCD display and can be adjusted with touch buttons. It has nighttime function (NTD), frost protection, weekly timer, Zzilent function (eg bedrooms), etc. Self explanatory menu for adjusting several important features, such as optional sensor type, as well as quick or manual setting of the unit. Optional color on screen background and text. The mTouch® One has key lock function (child safety) and parquet function (limiter if a floor sensor is used), as well as setting the max temperature to prevent unnecessary power consumption. NB: Limiter also when used as a power regulator.
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.009636879804 kg
Time representativeness
Data set valid until 2030
Technological representativeness
Technology description including background system Link to the CE Declaration and product data on our website: https://ctmlyng.no/produkter/mtouch-one-ph/

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.7
  • 0.01486
  • 4.884
  • 0.001788
  • 0.0000772
  • 366.5
  • 0
  • 0.001788
  • 0.03168
  • 0.03442
  • -1.127
Input
  • 0.1999
  • 0
  • 0
  • 0
  • -0.1999
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 10.9
  • 0.01486
  • 4.884
  • 0.001788
  • -0.1998
  • 366.5
  • 0
  • 0.001788
  • 0.03168
  • 0.03442
  • -1.127
Input
  • 104.6
  • 1.297
  • 0.4005
  • 0.1266
  • 0.004689
  • 28.34
  • 0
  • 0.1267
  • 0.1946
  • 0.1031
  • -9.339
Input
  • 2.591
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -2.597
  • 0
  • 0
Input
  • 107.2
  • 1.297
  • 0.4005
  • 0.1266
  • 0.004689
  • 28.34
  • 0
  • 0.1267
  • -2.402
  • 0.1031
  • -9.339
Input
  • 0.09316
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000891
  • 0.00008958
Input
  • 0.1776
  • 0.0004635
  • 0.003912
  • 0.00006398
  • 0.00000256
  • 0.2878
  • 0
  • 0.00006398
  • 0.0003076
  • 0.00008047
  • 0.00008517
Input
  • 0.03601
  • 0.002474
  • 0.01001
  • 0.0002284
  • 0.00001056
  • 0.7169
  • 0
  • 0.0002284
  • -0.00004172
  • 0.007718
  • -0.01383
Input
  • 0.08034
  • 0.0001174
  • 0.03705
  • 0.00001334
  • 0.000002213
  • 2.737
  • 0
  • 0.00001334
  • 0.0002139
  • 0.00005984
  • -0.006958
Output
  • 0.03531
  • 0.00007115
  • 0.003362
  • 0.000006459
  • 0
  • 0.01817
  • 0
  • 0.000006461
  • 0.00002058
  • 0.04143
  • -0.002472
Output
  • 0.9849
  • 0.04428
  • 0.03105
  • 0.006055
  • 0.02072
  • 2.18
  • 0
  • 0.006055
  • 0.02779
  • 0.02603
  • -0.1168
Output
  • 0.0003121
  • 0.000008841
  • 0.000003487
  • 8.633E-7
  • 0
  • 0.0002534
  • 0
  • 8.638E-7
  • 0.000001022
  • 4.245E-8
  • -0.00002892
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.009349
  • 0
  • 0.01927
  • 0
  • 0
  • 0
  • 0.0172
  • 0.000001984
  • -0.000003506
Output
  • 0
  • 0
  • 0.00651
  • 0
  • 0.001448
  • 0
  • 0
  • 0
  • 0.02212
  • 4.851E-8
  • -4.616E-7
Output
  • 0
  • 0
  • 0.003728
  • 0
  • 0.001185
  • 0
  • 0
  • 0
  • 0.03398
  • 0.000003147
  • -0.000001131
Output
  • 0
  • 0
  • 0.0564
  • 0
  • 0.01793
  • 0
  • 0
  • 0
  • 0.5141
  • 0.00004761
  • -0.00001711

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 106.9
  • 1.297
  • 0.3999
  • 0.1266
  • 0.004689
  • 28.29
  • 0
  • 0.1267
  • 0.1946
  • 0.103
  • -9.337
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.004888
  • 0.000001862
  • 0.000002082
  • 2.276E-7
  • 8.158E-9
  • 0.0001546
  • 0
  • 2.276E-7
  • 2.745E-7
  • 5.283E-8
  • -0.001036
Acidification potential, Accumulated Exceedance (AP)
  • 0.08312
  • 0.001205
  • 0.000225
  • 0.00004241
  • 0.000001587
  • 0.0162
  • 0
  • 0.00003434
  • 0.00008956
  • 0.00004327
  • -0.04358
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.006192
  • 0.00003284
  • 0.001457
  • 0.000003425
  • 0.03534
  • 0.05731
  • 0
  • 0.000003425
  • 0.00002857
  • 0.000007938
  • -0.001995
Global Warming Potential - fossil fuels (GWP-fossil)
  • 8.392
  • 0.09097
  • 0.03326
  • 0.008329
  • 0.0003352
  • 2.073
  • 0
  • 0.008401
  • 0.0779
  • 0.01137
  • -0.7053
Global Warming Potential - total (GWP-total)
  • 8.399
  • 0.09102
  • 0.03484
  • 0.008336
  • 0.03567
  • 2.139
  • 0
  • 0.008407
  • 0.07798
  • 0.01145
  • -0.7084
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.01408
  • 0.00004269
  • 0.0001189
  • 0.000002936
  • 1.109E-7
  • 0.008551
  • 0
  • 0.000002937
  • 0.00005631
  • 0.00007782
  • -0.001113
  • 8.433
  • 0.09102
  • 0.03424
  • 0.008335
  • 0.0003353
  • 2.134
  • 0
  • 0.008407
  • 0.07798
  • 0.01154
  • -0.7098
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001596
  • 6.238E-7
  • 0.000002079
  • 6.597E-8
  • 2.752E-9
  • 0.0001491
  • 0
  • 6.597E-8
  • 3.563E-7
  • 3.956E-7
  • -0.0002388
Eutrophication potential - marine (EP-marine)
  • 0.01221
  • 0.0002929
  • 0.00002702
  • 0.00001443
  • 5.25E-7
  • 0.00178
  • 0
  • 0.00001018
  • 0.00002074
  • 0.00001169
  • -0.002227
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.146
  • 0.00326
  • 0.0003342
  • 0.0001591
  • 0.000005683
  • 0.02317
  • 0
  • 0.0001126
  • 0.0002286
  • 0.00009731
  • -0.03059
Photochemical Ozone Creation Potential (POCP)
  • 0.04544
  • 0.0008895
  • 0.00009126
  • 0.00004539
  • 0.000001634
  • 0.006231
  • 0
  • 0.00003449
  • 0.00006553
  • 0.00004657
  • -0.008741
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.167E-7
  • 2.002E-8
  • 2.255E-9
  • 1.915E-9
  • 7E-11
  • 1.421E-7
  • 0
  • 1.915E-9
  • 2.022E-9
  • 5.3E-10
  • -0.0002448
Water (user) deprivation potential (WDP)
  • 289.6
  • 0.8116
  • 1.589
  • 0.1208
  • 0.005943
  • 4932
  • 0
  • 0.1208
  • 3.346
  • 0.1454
  • -21.22

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.3958
  • 0.005591
  • 0.006931
  • 0.0005534
  • 0.00002006
  • 0.5133
  • 0
  • 0.0005537
  • 0.001122
  • 0.0001754
  • -0.03357
Potential incidence of disease due to PM emissions (PM) 2
  • 4.971E-7
  • 3.849E-9
  • 1.675E-9
  • 6.05E-10
  • 2.4E-11
  • 1.161E-7
  • 0
  • 6.05E-10
  • 5.56E-10
  • 7.91E-10
  • -8.823E-8
Potential Soil quality index (SQP) 2
  • 46.33
  • 0.6761
  • 0.2122
  • 0.08733
  • 0.003146
  • 14.25
  • 0
  • 0.08734
  • 0.07014
  • 0.2671
  • -6.857
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 4.298E-7
  • 7.43E-10
  • 2E-9
  • 1.01E-10
  • 8E-12
  • 1.449E-7
  • 0
  • 1.01E-10
  • 4.104E-8
  • 2.81E-10
  • -9.829E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.076E-9
  • 0
  • 8.8E-11
  • 0
  • 0
  • 6.153E-9
  • 0
  • 0
  • 7E-10
  • 3.8E-11
  • -1.432E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 987.2
  • 0.9108
  • 1.793
  • 0.09327
  • 0.006253
  • 128.9
  • 0
  • 0.0933
  • 0.5423
  • 2.617
  • -308.2