Close Go back Collapse all sections
Process Data set: BGFILCOTEN one urban revision unit NW 100 Nr.0, L 1000 mm incl. grating (en) en

Key Data Set Information
Location AT
Geographical representativeness description Austria
Reference year 2025
Name
BGFILCOTEN one urban revision unit NW 100 Nr.0, L 1000 mm incl. grating
Use advice for data set For the geographies modeled in A1 and A2, refer to Product specification. Type of EPD: cradle to gate with options A4-A5, B1, C1-C4 and module D Stage of Material Production and Construction Module A1: Extraction and processing of raw materials Module A2: Transportation of raw materials to the plant Module A3: Precast concrete production at the plant and waste treatment Module A4: Transportation to installation site Use Stage Module B1: Carbonation during the utilization phase Disposal Stage Module C1: Demolition/Dismantling Module C2: Transportation of concrete demolition waste for processing Module C3: Sorting of waste components and recycling of concrete and other contained components Module C4: Landfilling of concrete and other contained components Credits and burdens outside the system boundaries Module D: Credits and burdens from recycling as a replacement for primary materials
Technical purpose of product or process Monolithic drainage channel BG-FILCOTEN one urban revision unit NW 100 Nr.0, L 1000 mm incl. grating (item no. 15110180) made of FILCOTEN HPC (High Performance Concrete). Channel-element with integrated edge out of cast iron and fiX locked ductile iron grate in cl. D400 + optional 4-fold bolt connection, for cleaning and maintaining of the channel run. Load class D400 Type I, tested according to EN1433; CE-certified Channel element with trapeze shape, channel joint sealable Inlet-slots 10/70 mm, according to EN 1433, Inlet cross section 195 cm²/m. Building biology tested and recommended by IBR (Institut für Baubiologie Rosenheim, DE). Fire-behaviour class: A1 according to EN13501 - non-combustible. 100% recyclable with U-A marking. Delivery and installation according to the manufacturer's installation instructions. Drainage channels out of concret - FILCOTEN® HPC (High Performance Concrete) - for vehicular and pedestrian areas according to standard EN 1433 Name of ingredient Share of total weight Country of origin Admixtures 0 - 2 % Austria Cement 10 - 25 % Austria Fibers 0 - 2 % Germany Iron 2 - 10 % Lithuania Iron 2 - 10 % Czech Republic Natural aggregates 25 - 50 % Austria Reinforcement fibre 0 - 2 % Austria Sand 10 - 25 % Austria Water 2 - 10 % Austria
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Concrete goods
General comment on data set The Emidat EPD Tool v1.0.0 was used for LCA modeling and calculation. Background data was used from ecoinvent database v3.10. Elementary flows (energy and fuels, ancillary materials and waste) data was collected on production-process-level. Using the total output of the production process in 2023, elementary flows are assigned to 1 declared unit based on mass. Environmental impacts of the following processes are considered to be negligible: minor auxiliary materials used during installation (sealants, adhesives, or fasteners), minor water use for cleaning precast concrete elements .
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-02-05 - 2030-02-05
Technological representativeness
Technology description including background system Unit Value Compressive Strength (Cylinder) N / mm² 70.0 Density kg / m³ 2364.32 Surface exposed to air m² 0.5 Total mass kg 41.8

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 21.1
  • 0.515
  • 21
  • 0
  • 0.0205
  • 0.515
  • 0.0156
  • 0.0143
  • -0.34
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 21.1
  • 0.515
  • 21
  • 0
  • 0.0205
  • 0.515
  • 0.0156
  • 0.0143
  • -0.34
Input
  • 61.3
  • 32.5
  • 517
  • 0
  • 3.35
  • 32.5
  • 2.55
  • 1.54
  • -1.08
Input
  • 0.591
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.449
  • 0
  • 0
Input
  • 61.9
  • 32.5
  • 517
  • 0
  • 3.35
  • 32.5
  • 2.1
  • 1.54
  • -1.08
Input
  • 0.158
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 31.8
Input
  • 6.83
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 16.1
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0635
  • 0.00472
  • 0.363
  • 0
  • 0.000218
  • 0.00472
  • 0.000165
  • 0.0016
  • -0.0452
Output
  • 0.195
  • 0.0472
  • 1.17
  • 0
  • 0.00374
  • 0.0472
  • 0.00285
  • 0.00171
  • -0.00428
Output
  • 6.69
  • 0.946
  • 33.4
  • 0
  • 0.0512
  • 0.946
  • 0.0389
  • 10.1
  • -0.0577
Output
  • 0.000734
  • 0.00000976
  • 0.000333
  • 0
  • 3.68E-7
  • 0.00000976
  • 2.8E-7
  • 2.39E-7
  • -0.00000248
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 1.25
  • 0
  • 0
  • 0
  • 0
  • 0
  • 31.8
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.048
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0928
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 61.9
  • 32.5
  • 517
  • 0
  • 3.35
  • 32.5
  • 2.55
  • 1.54
  • -1.08
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0000489
  • 0.00000618
  • 0.0002
  • 0
  • 9.18E-8
  • 0.00000618
  • 6.98E-8
  • 9.95E-8
  • -6.58E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.022
  • 0.00511
  • 0.138
  • 0
  • 0.00231
  • 0.00511
  • 0.00176
  • 0.000444
  • -0.000558
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.0218
  • 0.00109
  • 0.389
  • 0
  • 0.0000256
  • 0.00109
  • 0.000135
  • 0.000043
  • -0.00191
Global Warming Potential - fossil fuels (GWP-fossil)
  • 9.44
  • 2.16
  • 41
  • -0.0097
  • 0.256
  • 2.16
  • 0.195
  • 0.0627
  • -0.0732
Global Warming Potential - total (GWP-total)
  • 9.47
  • 2.17
  • 41.4
  • -0.0097
  • 0.256
  • 2.17
  • 0.195
  • 0.0628
  • -0.0751
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.00219
  • 0.000768
  • 0.0141
  • 0
  • 0.0000223
  • 0.000768
  • 0.0000169
  • 0.0000326
  • -0.0000115
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 0.000722
  • 0.000152
  • 0.00525
  • 0
  • 0.00000746
  • 0.000152
  • 0.00000567
  • 0.00000521
  • -0.00000577
Eutrophication potential - marine (EP-marine)
  • 0.00649
  • 0.00134
  • 0.0358
  • 0
  • 0.00107
  • 0.00134
  • 0.000815
  • 0.000169
  • -0.00022
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.0666
  • 0.0145
  • 0.397
  • 0
  • 0.0117
  • 0.0145
  • 0.00893
  • 0.00185
  • -0.00256
Photochemical Ozone Creation Potential (POCP)
  • 0.0209
  • 0.00887
  • 0.15
  • 0
  • 0.0035
  • 0.00887
  • 0.00266
  • 0.000662
  • -0.00074
Depletion potential of the stratospheric ozone layer (ODP)
  • 5.93E-8
  • 4.51E-8
  • 5.59E-7
  • 0
  • 3.92E-9
  • 4.51E-8
  • 2.98E-9
  • 1.81E-9
  • -1.27E-9
Water (user) deprivation potential (WDP)
  • 0.765
  • 0.163
  • 9.78
  • 0
  • 0.0082
  • 0.163
  • 0.00624
  • 0.0043
  • -0.0475

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.249
  • 0.0395
  • 1.32
  • 0
  • 0.0015
  • 0.0395
  • 0.00114
  • 0.000981
  • -0.0114
Potential incidence of disease due to PM emissions (PM) 2
  • 3.03E-7
  • 2.11E-7
  • 0.00000156
  • 0
  • 3.73E-7
  • 2.11E-7
  • 2.86E-7
  • 1.01E-8
  • -1.5E-8
Potential Soil quality index (SQP) 2
  • 0
  • 32.7
  • 219
  • 0
  • 0.235
  • 32.7
  • 0.178
  • 3.03
  • -2.1
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 2.14E-8
  • 3.19E-7
  • 0
  • 4.55E-10
  • 2.14E-8
  • 3.46E-10
  • 2.76E-10
  • -6.28E-10
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 1.39E-8
  • 1.16E-7
  • 0
  • 1E-9
  • 1.39E-8
  • 7.61E-10
  • 2.83E-10
  • -1.05E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 7.7
  • 108
  • 0
  • 0.475
  • 7.7
  • 0.361
  • 0.21
  • -0.472