Close Go back Collapse all sections
Process Data set: Roth QuickTemp ClimaComfort® systemplate (en) en

Key Data Set Information
Location DK
Geographical representativeness description Denmark, Sweden, Norway, Finland and UK
Reference year 2025
Name
Roth QuickTemp ClimaComfort® systemplate
Use advice for data set Module A1: Packaging has been included by average use of packaging pr. 1 m2 of product. Module A4: The transportation distances provided in this EPD are derived from precise data concerning the distances between production facility and various sales departments in different countries. Distribution from each of the sales departments to the end customers a distance of 300 km* is assumed. *Transportation by truck is assumed on a distribution of 80% EURO 6 and 20% EURO 5, based on data from the company's own logistics provider. Module A5/C1: Manual installation and demolition has been assumed. Module C2: The estimated transportation distance to the waste handling facility in this EPD is 100 km, assuming the use of a truck as the transport method.
Technical purpose of product or process With a structural height of only 17 mm, the Roth QuickTemp ClimaComfort® system is designed for installation on existing or new surfaces. The system is especially suitable for renovations, where the installation height is often crucial. The structure has a low weight, and the underfloor heating pipes are close to the surface. This creates a much faster response time in terms of underfloor heating than with a traditional screed/concrete underfloor heating structure.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Building boards
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on registered EPDs according to EN 15804, Ostfold Research databases, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included when specific information are missing. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.112576869319 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-07-07 - 2030-07-07
Technological representativeness
Technology description including background system The Roth QuickTemp ClimaComfort® system is a quick-regulating underfloor heating system that is easy to install in all types of buil;ding. This is a result of the specially developed system plate and the special Roth QuickTemp ClimaComfort®FLOW self-levelling and fibre;reinforced filling compound.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.14
  • 0.09352
  • 0.06914
  • 0
  • 0.005874
  • 0.1131
  • 0.003827
  • -11.41
Input
  • 2.289
  • 0
  • -1.566
  • 0
  • 0
  • -0.7229
  • 0
  • 0
Input
  • 12.43
  • 0.09352
  • -1.497
  • 0
  • 0.005874
  • -0.6099
  • 0.003827
  • -11.41
Input
  • 114.7
  • 6.42
  • 0.7918
  • 0
  • 0.4163
  • 0.8716
  • 0.03948
  • -1.847
Input
  • 33.57
  • 0
  • 0
  • 0
  • 0
  • -33.57
  • 0
  • 0
Input
  • 148.3
  • 6.42
  • 0.7918
  • 0
  • 0.4163
  • -32.7
  • 0.03948
  • -1.847
Input
  • 1.408
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.031
  • 0.00346
  • 0.02025
  • 0
  • 0.0002102
  • 0.002538
  • 0.00007543
  • -0.001998
Input
  • 0.05255
  • 0.01204
  • 0.0007193
  • 0
  • 0.0007505
  • 0
  • 0.005334
  • -0.6763
Input
  • 0.06964
  • 0.0006972
  • 0.0002987
  • 0
  • 0.00004383
  • 0.001096
  • 0.00005682
  • -0.01374
Output
  • 0.06741
  • 0.0003326
  • 0.0001917
  • 0
  • 0.00002123
  • 0
  • 0.03829
  • -0.00008681
Output
  • 0.8688
  • 0.3039
  • 0.2028
  • 0
  • 0.01989
  • 0.126
  • 0.0276
  • -0.04364
Output
  • 0.0003494
  • 0.00004372
  • 0.000004169
  • 0
  • 0.000002838
  • 0
  • 1.123E-7
  • -0.000009669
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.05624
  • 0
  • 0.1792
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.02789
  • 0
  • 0.01412
  • 0
  • 0
  • 1.465
  • 0
  • 0
Output
  • 0.02404
  • 0
  • 0.01159
  • 0
  • 0
  • 1.407
  • 0
  • 0
Output
  • 0.3637
  • 0
  • 0.1754
  • 0
  • 0
  • 21.28
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 117.5
  • 6.42
  • 0.7917
  • 0
  • 0.4162
  • 0.8649
  • 0.03947
  • -1.847
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00004407
  • 0.0000115
  • 6.761E-7
  • 0
  • 7.477E-7
  • 6.365E-7
  • 1.832E-8
  • -0.000001285
Acidification potential, Accumulated Exceedance (AP)
  • 0.02186
  • 0.00142
  • 0.000259
  • 0
  • 0.0001128
  • 0.0007465
  • 0.00001613
  • -0.001064
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.1641
  • 0.0001809
  • 0.3247
  • 0
  • 0.00001125
  • 0.08892
  • 0.000002897
  • -0.0002667
Global Warming Potential - fossil fuels (GWP-fossil)
  • 7.365
  • 0.4267
  • 0.05792
  • 0
  • 0.0276
  • 3.047
  • 0.006809
  • -0.1292
Global Warming Potential - total (GWP-total)
  • 7.209
  • 0.4271
  • 0.3827
  • 0
  • 0.02762
  • 3.136
  • 0.006813
  • -0.1339
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.007428
  • 0.0001705
  • 0.00003903
  • 0
  • 0.000009649
  • 0.00004109
  • 7.539E-7
  • -0.004449
  • 7.607
  • 0.427
  • 0.06038
  • 0
  • 0.02762
  • 2.978
  • 0.007005
  • -0.1319
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0002942
  • 0.000003456
  • 0.000004115
  • 0
  • 2.168E-7
  • 0.00000367
  • 7.235E-8
  • -0.00001148
Eutrophication potential - marine (EP-marine)
  • 0.004764
  • 0.0003447
  • 0.0000532
  • 0
  • 0.00003346
  • 0.0003253
  • 0.000004508
  • -0.0003479
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.05246
  • 0.003832
  • 0.0006407
  • 0
  • 0.0003701
  • 0.003317
  • 0.00005219
  • -0.003761
Photochemical Ozone Creation Potential (POCP)
  • 0.01501
  • 0.001305
  • 0.0001738
  • 0
  • 0.0001133
  • 0.0008158
  • 0.00001449
  • -0.001037
Depletion potential of the stratospheric ozone layer (ODP)
  • 9.141E-7
  • 9.607E-8
  • 7.771E-9
  • 0
  • 6.293E-9
  • 1.961E-8
  • 4.33E-10
  • -0.00941
Water (user) deprivation potential (WDP)
  • 491
  • 6.301
  • 3.884
  • 0
  • 0.3971
  • 2.169
  • 0.7706
  • -23

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.3281
  • 0.02809
  • 0.003027
  • 0
  • 0.001819
  • 0.003126
  • 0.0002068
  • -0.0118
Potential incidence of disease due to PM emissions (PM) 2
  • 1.955E-7
  • 2.652E-8
  • 3.145E-9
  • 0
  • 1.987E-9
  • 5.996E-9
  • 1.44E-10
  • -6.448E-8
Potential Soil quality index (SQP) 2
  • 48.57
  • 4.491
  • 0.2812
  • 0
  • 0.287
  • 0.2618
  • 0.111
  • -12.35
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 5.202E-8
  • 5.048E-9
  • 6.24E-10
  • 0
  • 3.31E-10
  • 5.173E-9
  • 1.89E-10
  • -9.629E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.524E-9
  • 0
  • 1.4E-11
  • 0
  • 0
  • 2.22E-10
  • 5E-12
  • -1.85E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 101.7
  • 4.755
  • 0.6081
  • 0
  • 0.3066
  • 3.704
  • 0.09817
  • -10.05