Close Go back Collapse all sections
Process Data set: Leca® S, Arlita® S, Leca Portugal (en) en

Key Data Set Information
Location NO
Geographical representativeness description Portugal, Spain and United Kingdom
Reference year 2025
Name
Leca® S, Arlita® S, Leca Portugal
Technical purpose of product or process Expanded clay is a lightweight granular aggregate produced from natural clay, subjected to a high-temperature thermal expansion process in a rotary kiln. This process imparts the material with a porous internal structure and a durable outer surface, resulting in a lightweight aggregate with excellent physical and mechanical performance. Leca® S, Arlita® S corresponds to the particle size fraction between 1 mm and 5 mm, obtained by screening the expanded granules after production. This aggregate is suitable for use in lightweight concrete, prefabricated elements, mortars for building construction, as well as for technical fills, fill layers, and various road infrastructure and civil engineering works, particularly where load reduction, thermal performance, and effective drainage are important factors. Expanded clay lightweight aggregate is a highly durable granular material, with a potentially unlimited service life when properly installed and used. It is a fully recyclable and reusable product, with 100% recovery potential at the end of its life cycle, thus contributing to the circularity of construction materials. This aggregate is characterized by a low dry bulk density, typically ranging between 200 and 800 kg/m³, depending on particle size distribution and degree of expansion. Despite its lightweight nature, it exhibits high mechanical strength and dimensional stability, making it suitable for a wide range of demanding construction and civil engineering applications.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Insulation
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804+A2. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-08-18 - 2030-08-18
Technological representativeness
Technology description including background system The relevant technical properties for Leca® S, Arlita® S are provided below: Loose bulk density (Test method: EN 1097-3): 430 kg/m³± 15% Grading(Test method: EN 933-1): 1-5 mm Compressibility and confined compressive strength(Test method: NS-EN 13055-1) more than 1,8 N/mm² Reaction to fire(Test method: NS-EN 13820): A1 Composition/content (Test method): - Chloride < 0,1% Cl - Acid soluble sulfate < 0,4% SO3 - Total sulfur < 0,2% S

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.776
  • 0.3915
  • 1.08E+3
  • 3.06
  • 0.0941
  • 0.06409
  • 0.7626
  • 0
  • 0.5556
  • -142
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.776
  • 0.3915
  • 1.08E+3
  • 3.06
  • 0.0941
  • 0.06409
  • 0.7626
  • 0
  • 0.5556
  • -142
Input
  • 5.245
  • 30.72
  • 697.5
  • 243.1
  • 17.39
  • 11.85
  • 54.04
  • 0
  • 15.52
  • -523.9
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 5.245
  • 30.72
  • 697.5
  • 243.1
  • 17.39
  • 11.85
  • 54.04
  • 0
  • 15.52
  • -523.9
Input
  • 11.48
  • 0
  • 0
  • 0
  • 0.008545
  • 0.00582
  • 0
  • 0
  • 0
  • -0.7741
Input
  • 0.05051
  • 0.01373
  • 2.379
  • 0.107
  • 0.002315
  • 0.001577
  • 0.02729
  • 0
  • 0.01153
  • -3.747
Input
  • 0.01256
  • 0.04638
  • 0.2089
  • 0.3588
  • 0.03407
  • 0.0232
  • 0.09744
  • 0
  • 0.0249
  • -2.933
Input
  • 0.003368
  • 0.003471
  • 0.2647
  • 0.02769
  • 0.0008954
  • 0.0006099
  • 0.005691
  • 0
  • 0.01909
  • -0.3482
Output
  • 0.0005078
  • 0.00167
  • 0.7429
  • 0.01331
  • 0.000512
  • 0.0003488
  • 0.002756
  • 0
  • 0
  • -0.05775
Output
  • 0.01619
  • 2.548
  • 5.521
  • 21.15
  • 0.0206
  • 0.01403
  • 2.583
  • 0
  • 68.75
  • -3.636
Output
  • 0.00002726
  • 0.0002097
  • 0.004707
  • 0.00166
  • 0.0001208
  • 0.00008225
  • 0.0003685
  • 0
  • 0
  • -0.001558
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.07175
  • 0
  • 0.004374
  • 0
  • 0
  • 206.3
  • 0
  • -0.6283
Output
  • 0
  • 0
  • 0.2644
  • 0
  • 0.0001426
  • 0
  • 0
  • 0
  • 0
  • -0.03763
Output
  • 0
  • 0
  • 0.1458
  • 0
  • 0.00004786
  • 0
  • 0
  • 0
  • 0
  • -0.08191
Output
  • 0
  • 0
  • 2.205
  • 0
  • 0.0007241
  • 0
  • 0
  • 0
  • 0
  • -1.239

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 4.331
  • 30.72
  • 697.2
  • 243.1
  • 17.39
  • 11.85
  • 54.04
  • 0
  • 15.52
  • -523.8
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.000001078
  • 0.00003595
  • 0.0003139
  • 0.0002669
  • 0.00000194
  • 0.000001321
  • 0.00009707
  • 0
  • 0.00000508
  • -0.000684
Acidification potential, Accumulated Exceedance (AP)
  • 0.002157
  • 0.008305
  • 0.5816
  • 0.06571
  • 0.005701
  • 0.003162
  • 0.01465
  • 0
  • 0.005016
  • -0.412
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.005013
  • 0.0008127
  • 0.02549
  • 0.006415
  • 0.0002387
  • 0.0001614
  • 0.001461
  • 0
  • 0.0006584
  • -0.1272
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.2624
  • 1.981
  • 51.64
  • 15.63
  • 1.273
  • 0.8671
  • 3.584
  • 0
  • 0.564
  • -51.66
Global Warming Potential - total (GWP-total)
  • 0.2678
  • 1.983
  • 51.74
  • 15.64
  • 1.274
  • 0.8673
  • 3.586
  • 0
  • 0.5648
  • -51.81
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0004008
  • 0.0005906
  • 0.06925
  • 0.004564
  • 0.00009962
  • 0.00006785
  • 0.001253
  • 0
  • 0.0001386
  • -0.02018
  • 0.2916
  • 1.983
  • 52.9
  • 15.64
  • 0.1987
  • 0.198
  • 3.586
  • 0
  • 0.5641
  • -51.8
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00002032
  • 0.00001516
  • 0.001585
  • 0.0001192
  • 0.000004602
  • 0.000003134
  • 0.00002814
  • 0
  • 0.000006392
  • -0.002567
Eutrophication potential - marine (EP-marine)
  • 0.0004036
  • 0.002494
  • 0.2467
  • 0.01976
  • 0.002094
  • 0.00105
  • 0.004345
  • 0
  • 0.001864
  • -0.05149
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.00533
  • 0.02758
  • 2.76
  • 0.2185
  • 0.02308
  • 0.01159
  • 0.04805
  • 0
  • 0.02057
  • -0.6208
Photochemical Ozone Creation Potential (POCP)
  • 0.001257
  • 0.008824
  • 0.6763
  • 0.07026
  • 0.006701
  • 0.003556
  • 0.01471
  • 0
  • 0.005888
  • -0.1677
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.217E-8
  • 4.572E-7
  • 0.000008171
  • 0.000003612
  • 2.729E-7
  • 1.859E-7
  • 8.17E-7
  • 0
  • 2.135E-7
  • -0.000003042
Water (user) deprivation potential (WDP)
  • 49.49
  • 24.16
  • 7967
  • 186.5
  • 3.695
  • 2.517
  • 51.55
  • 0
  • 95.72
  • -969

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.03112
  • 0.1343
  • 4.083
  • 1.063
  • 0.07452
  • 0.05076
  • 0.2362
  • 0
  • 0.07084
  • -1.087
Potential incidence of disease due to PM emissions (PM) 2
  • 1.686E-8
  • 1.711E-7
  • 0.00002388
  • 0.000001376
  • 9.986E-8
  • 6.203E-8
  • 2.58E-7
  • 0
  • 1.07E-7
  • -0.000003836
Potential Soil quality index (SQP) 2
  • 1.952
  • 33.79
  • 5406
  • 278.9
  • 2.207
  • 1.503
  • 37.26
  • 0
  • 59.75
  • -729.1
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.742E-9
  • 2.201E-8
  • 0.000001124
  • 1.72E-7
  • 8.036E-9
  • 5.149E-9
  • 4.3E-8
  • 0
  • 6.119E-9
  • -6.258E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.27E-10
  • 0
  • 4.092E-8
  • 0
  • 1.08E-9
  • 7.22E-10
  • 0
  • 0
  • 3.44E-10
  • -2.31E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 29.85
  • 22.48
  • 3263
  • 177.8
  • 9.517
  • 6.482
  • 39.8
  • 0
  • 8.467
  • -1267