Close Go back Collapse all sections
Process Data set: LAPP ÖLFLEX SOLAR H1 BUR 4mm2 El.nr: 1036102 and 1036103 (en) en

Key Data Set Information
Location FR
Geographical representativeness description Norway
Reference year 2024
Name
LAPP ÖLFLEX SOLAR H1 BUR 4mm2 El.nr: 1036102 and 1036103
Use advice for data set 1m LAPP ÖLFLEX SOLAR H1 BUR 4mm2 El.nr: 1036102 and 1036103
Technical purpose of product or process ÖLFLEX SOLAR H1 BUR cables are weather- and UV-resistant photovoltaic cables. These cross-linked, halogen-free and double-insulated solar cables are suitable for permanent outdoor use and especially for the interconnection of grounded and ungrounded photovoltaic power systems. They are applicable for the connection of solar panels among themselves and as extension cable between the individual module strings or the DC/AC inverter. Recommended use of cables for PV systems acc. to IEC 62930 and EN 50618: Intended for use in PV installations e.g. acc. to IEC 60364-7-712 resp. HD 60364-7-712. They are intended for permanent use outdoor and indoor, for free movable, free hanging and fixed installation. It is also permitted to install the cables in conduit or trunking systems. CPR classification: Dca-s2,d2,a1 Product Make-up Conductor: Fine wire strands of tinned copper acc. to IEC 60228 resp. EN IEC 60228, class 5 Core insulation: Cross-linked polyolefin co-polymer acc. to IEC 62930 and EN 50618, halogen free Colour: White Outer sheath: cross-linked polyolefin co-polymer acc. to IEC 62930 and EN 50618, halogen free Colour: black or blue or red
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.002067083335 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-11-22 - 2029-11-22
Technological representativeness
Technology description including background system Mechanical and thermal properties Minimum ambient temperature fixed installation -40 °C Conductor temperature, fixed installation up to +90 °C maximum conductor temperature during normal continuous operation acc. to IEC 62930 and EN 50618, up to +120 °C (maximum conductor temperature limited to 20.000 hours acc. to IEC 60216-2) acc. to IEC 62930 and EN 50618 Minimum temperature, during installation and handling -25 °C acc. to IEC 62930 and EN 50618 Max. storage temperature +45 °C acc. to IEC 62930, +40 °C acc. to EN 50618 Max. short circuit temperature +250 °C (5s) acc. to IEC 62930 and EN 50618 Minimum bending radius, occasional flexing:15 x outer diameter Minimum bending radius, stationary use 4 x outer diameter for outer diameter = 8 mm 5 x outer diameter for outer diameter > 8 mm Weather/UV resistance acc. to IEC 62930, Appendix E and EN 50618, Appendix E Ozone resistance acc. to IEC 62930 and EN 50618 Halogen-free acc. to IEC 62930 and EN 50618 acc. to IEC 60754-1 resp. EN 60754-1 and IEC 60754-2 resp. EN 60754-2 Smoke density acc. to IEC 62930 and EN 50618 acc. to IEC 61034-2 resp. EN 61034-2 Flammability flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 Acid and alkali resistance acc. to IEC 62930 and EN 50618 acc. to IEC 60811-404 resp. EN 60811-404 (oxalic acid and sodium hydroxide solution) Underground use acc. to UL 854, Section 23 (Impact Resistance Test) acc. to UL 854, Section 24 (Crushing Resistance Test) Presence of water Permanent submersion AD8 acc. to IEC 62440 and IEC 60364-5-51, tested acc. to EN-50525-2-21, appendix D and E General requirements These cables are conform to the EU Directive 2014/35/EU (Low Voltage Directive) A part of these cables (see www.lappkabel.com/cpr) are classified acc. to the EU-Regulation no. 305/2011 (CPR). Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS)

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.5403
  • 0.00171
  • 0.2514
  • 0.002409
  • 0.00003249
  • 0.1528
  • 0
  • 0.0001803
  • 0.00362
  • 0.001062
  • -0.5624
Input
  • 0.0694
  • 0
  • 0
  • 0
  • -0.0694
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.6097
  • 0.00171
  • 0.2514
  • 0.002409
  • -0.06937
  • 0.1528
  • 0
  • 0.0001803
  • 0.003619
  • 0.001061
  • -0.5624
Input
  • 2.904
  • 0.1194
  • 1.654
  • 0.1915
  • 0.001581
  • 2.088
  • 0
  • 0.0126
  • 0.03064
  • 0.01254
  • -0.6205
Input
  • 1.287
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -1.726
  • 0
  • 0
Input
  • 4.19
  • 0.1194
  • 1.654
  • 0.1915
  • 0.001581
  • 2.088
  • 0
  • 0.0126
  • -1.695
  • 0.01254
  • -0.6788
Input
  • 0.005098
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000001153
  • 0.01855
Input
  • 0.01542
  • 0.00006116
  • 0.001814
  • 0.00008426
  • 9.476E-7
  • 0.002203
  • 0
  • 0.000006451
  • 0.00006632
  • 0.00002292
  • 0.001705
Input
  • 0.0008821
  • 0.0002187
  • 0.004628
  • 0.0002824
  • 0.00001079
  • 0.005542
  • 0
  • 0.00002306
  • -0.00001729
  • 0.00009875
  • -0.01607
Input
  • 0.003699
  • 0.00001277
  • 0.001526
  • 0.00002179
  • 0.000001151
  • 0.0006001
  • 0
  • 0.000001347
  • 0.0006706
  • 0.00001502
  • -0.001955
Output
  • 0.001713
  • 0.000006159
  • 0.003326
  • 0.00001048
  • 0
  • 0.00005183
  • 0
  • 6.496E-7
  • 0.000009404
  • 0.001282
  • -0.0007208
Output
  • 0.06286
  • 0.005808
  • 0.01596
  • 0.01664
  • 0.005
  • 0.002799
  • 0
  • 0.0006126
  • 0.001071
  • 0.04183
  • -0.03184
Output
  • 0.00001045
  • 8.136E-7
  • 0.00002099
  • 0.000001308
  • 0
  • 0.0000272
  • 0
  • 8.58E-8
  • 1.471E-7
  • 8.247E-8
  • -9.208E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01209
  • 0
  • 1.173E-7
  • 0
  • 0
  • 0
  • 0.01801
  • 0.000002806
  • -0.000726
Output
  • 0
  • 0
  • 0.01426
  • 0
  • 0.004959
  • 0
  • 0
  • 0
  • 0.015
  • 1.123E-7
  • -0.0000956
Output
  • 0
  • 0
  • 0.00873
  • 0
  • 0.00345
  • 0
  • 0
  • 0
  • 0.03983
  • 0.000003776
  • -0.0002342
Output
  • 0
  • 0
  • 0.1321
  • 0
  • 0.05219
  • 0
  • 0
  • 0
  • 0.6026
  • 0.00005713
  • -0.003544

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 4.079
  • 0.1194
  • 1.654
  • 0.1915
  • 0.001581
  • 2.088
  • 0
  • 0.0126
  • 0.03064
  • 0.01254
  • -0.6207
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0000869
  • 2.182E-7
  • 3.713E-7
  • 2.101E-7
  • 2.182E-9
  • 3.88E-7
  • 0
  • 2.301E-8
  • 4.59E-8
  • 4.645E-9
  • -0.00005968
Acidification potential, Accumulated Exceedance (AP)
  • 0.007053
  • 0.0000227
  • 0.00008092
  • 0.00003796
  • 0.000001082
  • 0.0000828
  • 0
  • 0.000002394
  • 0.00001783
  • 0.000004511
  • -0.01068
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.004163
  • 0.000003269
  • 0.001574
  • 0.00000505
  • 0.00758
  • 0.00006119
  • 0
  • 3.448E-7
  • 0.000008934
  • 4.67E-7
  • -0.0003026
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.2028
  • 0.007899
  • 0.02351
  • 0.01179
  • 0.0001345
  • 0.01597
  • 0
  • 0.000833
  • 0.06629
  • 0.003511
  • -0.0672
Global Warming Potential - total (GWP-total)
  • 0.1988
  • 0.007905
  • 0.0251
  • 0.0118
  • 0.007715
  • 0.01604
  • 0
  • 0.0008337
  • 0.0663
  • 0.003511
  • -0.0677
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0001906
  • 0.000002811
  • 0.00001437
  • 0.000003592
  • 3.451E-8
  • 0.00001314
  • 0
  • 2.965E-7
  • 0.000001697
  • 1.767E-7
  • -0.0001977
  • 0.203
  • 0.007904
  • 0.02478
  • 0.0118
  • 0.0001346
  • 0.01604
  • 0
  • 0.0008337
  • 0.06635
  • 0.002366
  • -0.03396
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00005749
  • 6.31E-8
  • 5.799E-7
  • 9.38E-8
  • 1.613E-9
  • 6.375E-7
  • 0
  • 6.656E-9
  • 6.54E-8
  • 1.18E-8
  • -0.00007209
Eutrophication potential - marine (EP-marine)
  • 0.0005054
  • 0.000004492
  • 0.00001773
  • 0.000008313
  • 4.642E-7
  • 0.00001347
  • 0
  • 4.737E-7
  • 0.00000569
  • 0.000004563
  • -0.0004475
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.007315
  • 0.00005024
  • 0.0001678
  • 0.00009272
  • 0.000004972
  • 0.0001474
  • 0
  • 0.000005299
  • 0.00006127
  • 0.00001729
  • -0.006892
Photochemical Ozone Creation Potential (POCP)
  • 0.001965
  • 0.00001925
  • 0.0000467
  • 0.00003641
  • 0.000001278
  • 0.00004056
  • 0
  • 0.00000203
  • 0.00001606
  • 0.000005468
  • -0.001872
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.336E-8
  • 1.79E-9
  • 7.578E-9
  • 2.843E-9
  • 2.1E-11
  • 9.161E-9
  • 0
  • 1.89E-10
  • 7.26E-10
  • 1.57E-10
  • -0.0002766
Water (user) deprivation potential (WDP)
  • 14.07
  • 0.1155
  • 25.02
  • 0.1468
  • 0.002434
  • 30.3
  • 0
  • 0.01218
  • 0.5718
  • 0.1967
  • 2.795

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01156
  • 0.000522
  • 0.01631
  • 0.0008369
  • 0.000005731
  • 0.02098
  • 0
  • 0.00005505
  • 0.0001395
  • 0.0000692
  • -0.00105
Potential incidence of disease due to PM emissions (PM) 2
  • 2.113E-8
  • 4.83E-10
  • 4.91E-10
  • 1.083E-9
  • 1.3E-11
  • 3.7E-10
  • 0
  • 5.1E-11
  • 1.01E-10
  • 7.3E-11
  • -2.318E-8
Potential Soil quality index (SQP) 2
  • 2.492
  • 0.08354
  • 0.09679
  • 0.2195
  • 0.0008863
  • 0.1032
  • 0
  • 0.00881
  • 0.01044
  • 0.03775
  • -1.606
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.125E-7
  • 9.6E-11
  • 4.46E-10
  • 1.35E-10
  • 1E-11
  • 4E-10
  • 0
  • 1E-11
  • 3.5E-10
  • 2.6E-11
  • -1.187E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.488E-9
  • 0
  • 1.8E-11
  • 0
  • 0
  • 1.7E-11
  • 0
  • 0
  • 4E-12
  • 0
  • -1.387E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 85.23
  • 0.08853
  • 0.594
  • 0.14
  • 0.0018
  • 0.6433
  • 0
  • 0.009337
  • 1.335
  • 7.443
  • -98.23