Close Go back Collapse all sections
Process Data set: FQ 3G2,5 Flexror 16mm (ALC) (en) en

Key Data Set Information
Location NO
Geographical representativeness description Sweden
Reference year 2025
Name
FQ 3G2,5 Flexror 16mm (ALC)
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Flexslang med fördragna ledare FQ 450/750 V Flexibla korrugerade polypropenrör med fördragna ledare för öppen och dold installation samt ingjutning i betong. Flexrören är tillverkade i halogenfritt material och godkända för installation inom -25°C till 70°C samt ingjutning upp till 750 N. CPR klass: Dca EN50575 ROHS 2002/95/WE L.V.D. 2014/35/EU Pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. H07Z1-R- halogen free insulated wire. The solution may be installed in open or closed environment, behind ceiling, in wall or below deck - embedded in concrete. Cable shall be used according to reference EN 50565-1 and EN 50565-2-18A/B. Contact with water is not permitted. Fire performance according to CPR EN 50575. The conduit material is a halogen free, flame retardant, self-extinguishing polypropylene with low toxic and smoke emission. Construction standard - Pipe: EN 611386-1; EN 61386-22 Pipe designation: ICTA 34423 Construction standard- Cable: EN 50525-1; EN 50525-3-31
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Technological representativeness
Technology description including background system CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CABLE Construction standards EN 50525-1; EN 50525-3-31 Conductor Solid copper wire IEC 60228 Class 2 Insulation - conductor Thermoplastic HFFR TI 7 Conductor color - Cenelec G/G; Light Blue; Brown; Black; Whi- te; Orange; Dark Blue; Dark Blue; Red ; B/R and B/W Marking Wire: TECCON H07VZ1-R; Packaging: acc. LVD Voltage - nominal Uo/U 450/750V Voltage - test 2kV Temperature classification 70° Temperature Max - Short circuit 250° Resistant to fire performance IEC 60332-1-2 CPR EN 50575 compliance Eca DoP 17_0001_00 Temperature - operation -5 - 70°C Temperature - installation 5 - 40°C Temperature - installed -30 to +70 CPR EN 50575 compliance Dca DOP 17:0004_00 Art.nr. 1251631

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.9773
  • 0.00248
  • 0.1328
  • 0.004023
  • 0.02309
  • 0
  • 0.0004354
  • 0.0006216
  • 0.002024
  • -3.303
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.9773
  • 0.00248
  • 0.1328
  • 0.004023
  • 0.02309
  • 0
  • 0.0004354
  • 0.0006215
  • 0.002024
  • -3.303
Input
  • 9.211
  • 0.1979
  • 0.01091
  • 0.281
  • 0.2033
  • 0
  • 0.03085
  • 0.02077
  • 0.02153
  • -2.265
Input
  • 3.032
  • 0
  • 0
  • 0
  • -0.07869
  • 0
  • 0
  • -2.891
  • 0
  • -0.3023
Input
  • 12.24
  • 0.1979
  • 0.01091
  • 0.281
  • 0.1246
  • 0
  • 0.03085
  • -2.87
  • 0.02153
  • -2.567
Input
  • 0.01473
  • 0
  • 0
  • 0
  • 0.0003119
  • 0
  • 0
  • 0
  • 0.00003175
  • 0.04766
Input
  • 0.01069
  • 0.00008519
  • 0.0001046
  • 0.0001439
  • 0.0002295
  • 0
  • 0.00001558
  • 0.00001729
  • 0.0000427
  • 0.003433
Input
  • 0.01065
  • 0.0003836
  • 0.0002608
  • 0.0005146
  • 0.0002615
  • 0
  • 0.00005563
  • 0
  • 0.000698
  • -0.141
Input
  • 0.01114
  • 0.00001861
  • 0.0009917
  • 0.00003005
  • 0.0002535
  • 0
  • 0.000003249
  • 0.00005794
  • 0.00002653
  • -0.008534
Output
  • 0.006261
  • 0.000009786
  • 0.000006581
  • 0.00001449
  • 0.0002583
  • 0
  • 0.000001573
  • 0
  • 0.006404
  • -0.001884
Output
  • 0.1649
  • 0.007466
  • 0.00319
  • 0.01367
  • 0.009268
  • 0
  • 0.001474
  • 0
  • 0.06986
  • -0.08978
Output
  • 0.00001659
  • 0.000001355
  • 9.178E-8
  • 0.000001914
  • 4.208E-7
  • 0
  • 2.104E-7
  • 0
  • 1.444E-7
  • -0.000004186
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.001813
  • 0
  • 0.004134
  • 0
  • 0
  • 0.1048
  • 0.000003172
  • -0.00187
Output
  • 0
  • 0
  • 6E-8
  • 0
  • 0.002272
  • 0
  • 0
  • 0.1135
  • 8.794E-7
  • -0.0002678
Output
  • 0
  • 0
  • 9.218E-8
  • 0
  • 0.003997
  • 0
  • 0
  • 0.1996
  • 0.00001207
  • -0.0006405
Output
  • 0
  • 0
  • 0.000001395
  • 0
  • 0.06047
  • 0
  • 0
  • 3.02
  • 0.0001826
  • -0.00969

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 11.99
  • 0.1979
  • 0.0109
  • 0.281
  • 0.2604
  • 0
  • 0.03085
  • 0.02077
  • 0.02153
  • -2.542
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001536
  • 3.035E-7
  • 5.696E-8
  • 5.134E-7
  • 0.000003198
  • 0
  • 5.542E-8
  • 1.118E-8
  • 7.947E-9
  • -0.0001537
Acidification potential, Accumulated Exceedance (AP)
  • 0.05445
  • 0.0001473
  • 0.000006053
  • 0.00005342
  • 0.001132
  • 0
  • 0.000008363
  • 0.00003915
  • 0.000007415
  • -0.02766
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.01348
  • 0.000005145
  • 0.00002078
  • 0.000007693
  • 0.0002795
  • 0
  • 8.342E-7
  • 0.000002548
  • 5.335E-7
  • -0.0009265
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.6939
  • 0.01366
  • 0.0008629
  • 0.01859
  • 0.02171
  • 0
  • 0.002046
  • 0.3115
  • 0.004762
  • -0.2109
Global Warming Potential - total (GWP-total)
  • 0.7079
  • 0.01366
  • 0.0008868
  • 0.0186
  • 0.022
  • 0
  • 0.002047
  • 0.3116
  • 0.004762
  • -0.213
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0005213
  • 0.000006083
  • 0.000003111
  • 0.000006615
  • 0.00001116
  • 0
  • 7.152E-7
  • 3.825E-7
  • 3.066E-7
  • -0.001169
  • 0.6974
  • 0.01366
  • 0.0007902
  • 0.0186
  • 0.0214
  • 0
  • 0.002047
  • 0.3115
  • 0.004867
  • -0.1248
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0005311
  • 9.505E-8
  • 5.433E-8
  • 1.485E-7
  • 0.000011
  • 0
  • 1.607E-8
  • 2.51E-8
  • 1.649E-8
  • -0.0001872
Eutrophication potential - marine (EP-marine)
  • 0.001874
  • 0.00003482
  • 7.726E-7
  • 0.00001057
  • 0.00004064
  • 0
  • 0.00000248
  • 0.00001876
  • 0.000006721
  • -0.001212
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.02662
  • 0.0003878
  • 0.000009041
  • 0.0001182
  • 0.000568
  • 0
  • 0.00002743
  • 0.0002029
  • 0.00002918
  • -0.01838
Photochemical Ozone Creation Potential (POCP)
  • 0.008649
  • 0.0001084
  • 0.000002465
  • 0.00004529
  • 0.0001839
  • 0
  • 0.000008398
  • 0.0000487
  • 0.00000909
  • -0.005021
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.33E-8
  • 3.041E-9
  • 6.1E-11
  • 4.21E-9
  • 8.8E-10
  • 0
  • 4.66E-10
  • 2.42E-10
  • 2.71E-10
  • -0.002092
Water (user) deprivation potential (WDP)
  • 7.097
  • 0.1556
  • 1.788
  • 0.2718
  • 0.2043
  • 0
  • 0.02943
  • 0.04773
  • 0.3727
  • 0.912

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01736
  • 0.0008612
  • 0.0001888
  • 0.001228
  • 0.0004182
  • 0
  • 0.0001349
  • 0.00003569
  • 0.0001236
  • -0.005001
Potential incidence of disease due to PM emissions (PM) 2
  • 1.008E-7
  • 6.13E-10
  • 4.5E-11
  • 1.138E-9
  • 2.137E-9
  • 0
  • 1.47E-10
  • 1.7E-10
  • 1.29E-10
  • -6.962E-8
Potential Soil quality index (SQP) 2
  • 5.414
  • 0.1121
  • 0.006023
  • 0.1966
  • 0.1225
  • 0
  • 0.02127
  • 0.002575
  • 0.0568
  • -5.961
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 8.727E-7
  • 1.23E-10
  • 5.3E-11
  • 2.28E-10
  • 1.807E-8
  • 0
  • 2.5E-11
  • 2.63E-10
  • 3.2E-11
  • -3.066E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.831E-9
  • 0
  • 2E-12
  • 0
  • 2.04E-10
  • 0
  • 0
  • 7E-12
  • 1E-12
  • -3.597E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 409.1
  • 0.1393
  • 0.04726
  • 0.2083
  • 8.87
  • 0
  • 0.02272
  • 0.0617
  • 19.7
  • -254