Close Go back Collapse all sections
Process Data set: IFSI-EMC Pure 1kV 2x4/4mm² ER (en) en

Key Data Set Information
Location FI
Geographical representativeness description Norway
Reference year 2024
Name
IFSI-EMC Pure 1kV 2x4/4mm² ER
Technical purpose of product or process IFSI-EMC PURE 1KV CU Power cable with up to 1 kV operating voltage. Allowed indoors, outdoors and as a ground cable without extra protection. The Cu screen is 100% tight, has low coupling impedance and meets the EMC directive. The 3-conductor is symmetrically constructed and has a CU screen from 1.5mm². Halogen-free cable is recommended used when it is important to avoid the formation of dense smoke and corrosive gases in the event of an overheating or fire. Cables with AAL screen has a construction with an AL-foil in contact with a massive CU wire. The AL foil has an longitudinal slit and is not 100% covering (slit does not exceed 4mm). When applied to installation with highly sensitive equipment use IFSI-EMC Pure with CU screen. Conductor: Class 1 Round, solid copper Conductor surface Bare Core insulation material: XLPE Armouring/reinforcement material: Copper, bare Screen construction: Metallized foil Screen: Yes Screen material Copper, bare Concentric conductor: Copper Material inner sheath: Halogen-free polymer Material outer sheath: Halogen-free polymer Cable shape: Round Core colours 2X: Blue, brown
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 5.95471698E-4 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-06-19" - "2029-06-19"
Technological representativeness
Technology description including background system IFSI-EMC Pure 1kV 2x4/4mm² ER SAP code 20216056 El no. 1003802 STANDARDS APPLIED: IEC 60502-1 EN 50575:2014+A1:2016 EN 13501-6, class Cca-s1,d1,a1

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 2.157
  • 0.01239
  • 0.2671
  • 0.01769
  • 0.04916
  • 0
  • 0
  • 0
  • 0
  • 0
  • 13.18
  • 0
  • 0
  • 0.003041
  • 0.001587
  • 0.002829
  • -1.217
Input
  • 0.01783
  • 0
  • 0
  • 0
  • 0.00001762
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.01694
  • 0
  • 0
Input
  • 2.174
  • 0.01239
  • 0.2671
  • 0.01769
  • 0.04918
  • 0
  • 0
  • 0
  • 0
  • 0
  • 13.18
  • 0
  • 0
  • 0.003041
  • -0.01536
  • 0.002829
  • -1.217
Input
  • 10.68
  • 1.133
  • 3.411
  • 1.254
  • 0.3308
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.019
  • 0
  • 0
  • 0.2155
  • 0.02918
  • 0.0343
  • -0.4468
Input
  • 3.258
  • 0
  • 0
  • 0
  • 0.007406
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.02826
  • 0
  • -2.86
  • 0
  • 0
Input
  • 13.94
  • 1.133
  • 3.411
  • 1.254
  • 0.3382
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.019
  • 0
  • -0.02826
  • 0.2155
  • -2.831
  • 0.0343
  • -0.4468
Input
  • 0.02589
  • 0
  • 0.0005422
  • 0
  • 0.0005287
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.008752
Input
  • 0.04411
  • 0.0004128
  • 0.0002216
  • 0.0006331
  • 0.0009093
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01035
  • 0
  • 0
  • 0.0001088
  • 0.00003432
  • 0.0000587
  • 0.0006378
Input
  • 0.004495
  • 0.001213
  • 0.0002636
  • 0.00226
  • 0.0001659
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02578
  • 0
  • 0
  • 0.0003886
  • 0
  • 0.00006421
  • -0.06401
Input
  • 0.05459
  • 0.00009297
  • 0.001208
  • 0.000132
  • 0.001126
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.09842
  • 0
  • 0
  • 0.00002269
  • 0.0002381
  • 0.00004347
  • -0.002068
Output
  • 0.005149
  • 0.00005291
  • 0.003168
  • 0.00006393
  • 0.0002952
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0006533
  • 0
  • 0
  • 0.00001099
  • 0
  • 0.006327
  • -0.0003473
Output
  • 0.2132
  • 0.03317
  • 0.01718
  • 0.05991
  • 0.009091
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07838
  • 0
  • 0
  • 0.0103
  • 0
  • 0.1311
  • -0.01866
Output
  • 0.00003728
  • 0.000007794
  • 0.000058
  • 0.000008547
  • 0.000002237
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00000911
  • 0
  • 0
  • 0.000001469
  • 0
  • 2.351E-7
  • -0.000001241
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.0169
  • 0
  • 0.001505
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05833
  • 0.000008018
  • -0.0003425
Output
  • 0
  • 0
  • 0.01422
  • 0
  • 0.002159
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.09371
  • 1.961E-7
  • -0.0000451
Output
  • 0
  • 0
  • 0.009504
  • 0
  • 0.003056
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1433
  • 0.00001272
  • -0.0001105
Output
  • 0
  • 0
  • 0.1438
  • 0
  • 0.04623
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.168
  • 0.0001925
  • -0.001672

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 13.86
  • 1.132
  • 3.411
  • 1.253
  • 0.3944
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.017
  • 0
  • 0
  • 0.2155
  • 0.02906
  • 0.0343
  • -0.4469
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001914
  • 0.00000145
  • 4.724E-7
  • 0.000002252
  • 0.000003912
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005558
  • 0
  • 0
  • 3.871E-7
  • 2.282E-8
  • 1.15E-8
  • -0.00002826
Acidification potential, Accumulated Exceedance (AP)
  • 0.02846
  • 0.001404
  • 0.0001176
  • 0.0003398
  • 0.0006076
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005823
  • 0
  • 0
  • 0.00005842
  • 0.00004667
  • 0.00001164
  • -0.005127
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.007104
  • 0.00002749
  • 0.001431
  • 0.0000339
  • 0.000387
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002061
  • 0
  • 0
  • 0.000005827
  • 0.008902
  • 0.00185
  • -0.000165
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.8702
  • 0.08021
  • 0.01569
  • 0.08313
  • 0.02551
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07453
  • 0
  • 0
  • 0.01429
  • 0.2156
  • 0.01081
  • -0.04248
Global Warming Potential - total (GWP-total)
  • 0.8782
  • 0.08027
  • 0.01715
  • 0.08319
  • 0.02592
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0769
  • 0
  • 0
  • 0.0143
  • 0.2245
  • 0.01266
  • -0.04311
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0009283
  • 0.00003799
  • 0.00002154
  • 0.00002906
  • 0.00002036
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0003075
  • 0
  • 0
  • 0.000004996
  • 8.456E-7
  • 4.307E-7
  • -0.0004645
  • 0.8781
  • 0.08027
  • 0.01687
  • 0.08319
  • 0.02585
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07675
  • 0
  • 0
  • 0.0143
  • 0.2209
  • 0.01306
  • -0.02703
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0002496
  • 4.88E-7
  • 5.439E-7
  • 6.528E-7
  • 0.000005028
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00000536
  • 0
  • 0
  • 1.122E-7
  • 4.07E-8
  • 2.074E-8
  • -0.00003497
Eutrophication potential - marine (EP-marine)
  • 0.001869
  • 0.0003706
  • 0.00003683
  • 0.0001008
  • 0.00004834
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00006401
  • 0
  • 0
  • 0.00001733
  • 0.00002228
  • 0.00001712
  • -0.0002401
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.02679
  • 0.004113
  • 0.0004109
  • 0.001115
  • 0.000654
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0008332
  • 0
  • 0
  • 0.0001916
  • 0.000229
  • 0.00004623
  • -0.003565
Photochemical Ozone Creation Potential (POCP)
  • 0.007228
  • 0.001086
  • 0.0000977
  • 0.0003412
  • 0.0001765
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002241
  • 0
  • 0
  • 0.00005867
  • 0.00005522
  • 0.00001581
  • -0.0009698
Depletion potential of the stratospheric ozone layer (ODP)
  • 5.203E-8
  • 1.737E-8
  • 1.431E-8
  • 1.895E-8
  • 2.071E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.111E-9
  • 0
  • 0
  • 3.258E-9
  • 4.55E-10
  • 4.47E-10
  • -0.0009155
Water (user) deprivation potential (WDP)
  • 43.44
  • 0.7309
  • 1.639
  • 1.196
  • 0.9544
  • 0
  • 0
  • 0
  • 0
  • 0
  • 177.4
  • 0
  • 0
  • 0.2056
  • 0.194
  • 0.5222
  • -0.6001

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.04316
  • 0.004917
  • 0.1505
  • 0.005479
  • 0.004087
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01846
  • 0
  • 0
  • 0.000942
  • 0.00007218
  • 0.0001907
  • -0.00148
Potential incidence of disease due to PM emissions (PM) 2
  • 8.515E-8
  • 4.196E-9
  • 1.74E-9
  • 5.985E-9
  • 1.95E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.175E-9
  • 0
  • 0
  • 1.029E-9
  • 2.07E-10
  • 2.18E-10
  • -1.632E-8
Potential Soil quality index (SQP) 2
  • 6.79
  • 0.5223
  • 1.262
  • 0.8642
  • 0.1909
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5124
  • 0
  • 0
  • 0.1486
  • 0.005236
  • 0.1021
  • -1.788
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 4.312E-7
  • 8.65E-10
  • 6.33E-10
  • 9.97E-10
  • 8.686E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.212E-9
  • 0
  • 0
  • 1.71E-10
  • 5.48E-10
  • 3.7E-11
  • -5.682E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.039E-9
  • 0
  • 2.5E-11
  • 0
  • 1.22E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.21E-10
  • 0
  • 0
  • 0
  • 1.1E-11
  • 1E-12
  • -6.68E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 314.3
  • 0.7573
  • 1.219
  • 0.9232
  • 6.835
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.635
  • 0
  • 0
  • 0.1587
  • 0.4297
  • 24.11
  • -47.18