Close Go back Collapse all sections
Process Data set: Protecta FR Graphite Plate (en) en

Key Data Set Information
Location GB
Geographical representativeness description Global. Transport to market is not included in this EPD.
Reference year 2024
Name
Protecta FR Graphite Plate
Use advice for data set The life cycle analysis is a cradle-to-gate (A1 - A3) study. It includes the extraction and production of raw materials and packaging, transportation to the manufacturing site, as well as the manufacturing process itself.
Technical purpose of product or process Protecta FR Graphite Plate is a preformed self-adhesive intumescent plate, used to reinstate the fire resistance performance of flexible wall constructions when punctured with plastic wall boxes. It is used where the walls have been provided with apertures for the penetration of conduits and cables into socket boxes, on one or both sides of the wall. The graphite plate immediately reacts to fire through the heat and automatically expands and fills up the box, preventing fire from passing through. Fitting FR Graphite Plate will reinstate the fire resistance performance of flexible wall constructions for up to 120 minutes. It also prevents the passage of fire through the electrical conduits between socket boxes.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Technical-chemical building materials products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-10-30" - "2029-10-30"
Technological representativeness
Technology description including background system The product has a third-party verified ETA issued in accordance with regulation (EU) No 305/2011 on the basis of EAD 350454-00-1104, September 2017, tested to EN 1366-3 in conjunction with EN 1363-1. The product hold the following approval marks; CE-mark for Europe. For more information, please see https://protecta.co.uk/product/fire-rated-graphite-plate/

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Input
  • 3.412
  • 0.02134
  • 0.2939
  • 0.02928
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 3.412
  • 0.02134
  • 0.2939
  • 0.02928
Input
  • 42.1
  • 1.866
  • 1.067
  • 2.972
Input
  • 2.53
  • 0
  • 0
  • 0
Input
  • 44.63
  • 1.866
  • 1.067
  • 2.972
Input
  • 0.007959
  • 0
  • 0
  • 0
Input
  • 0.07577
  • 0.0007173
  • 0.0004263
  • 0.0009379
Input
  • 0.02175
  • 0.002986
  • 0.0004959
  • 0.002415
Input
  • 0.0603
  • 0.000163
  • 0.0004301
  • 0.0002205
Output
  • 0.01019
  • 0.00008977
  • 0.00321
  • 0.0001349
Output
  • 0.6584
  • 0.06597
  • 0.006311
  • 0.06765
Output
  • 0.0000844
  • 0.00001282
  • 0.000008584
  • 0.00002052
Output
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.0108
  • 0
Output
  • 0
  • 0
  • 0.01415
  • 0
Output
  • 0
  • 0
  • 0.00841
  • 0
Output
  • 0
  • 0
  • 0.1272
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Abiotic depletion potential - fossil resources (ADPF)
  • 42.88
  • 1.866
  • 1.067
  • 2.972
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001291
  • 0.000002472
  • 6.494E-7
  • 0.000003277
Acidification potential, Accumulated Exceedance (AP)
  • 0.02349
  • 0.001967
  • 0.0001831
  • 0.004487
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.01125
  • 0.00004652
  • 0.001684
  • 0.00006952
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.507
  • 0.1306
  • 0.0523
  • 0.2165
Global Warming Potential - total (GWP-total)
  • 2.52
  • 0.1307
  • 0.05405
  • 0.2167
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.002007
  • 0.00006063
  • 0.0000597
  • 0.0001115
  • 2.538
  • 0.1307
  • 0.06291
  • 0.2167
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00009878
  • 8.365E-7
  • 0.000001339
  • 0.000001191
Eutrophication potential - marine (EP-marine)
  • 0.00236
  • 0.0005096
  • 0.000037
  • 0.001106
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.02784
  • 0.005659
  • 0.0004028
  • 0.0123
Photochemical Ozone Creation Potential (POCP)
  • 0.0118
  • 0.001516
  • 0.0001048
  • 0.003248
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.54E-7
  • 2.886E-8
  • 4.667E-9
  • 4.565E-8
Water (user) deprivation potential (WDP)
  • 81.8
  • 1.276
  • 4.617
  • 1.596

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.08446
  • 0.008107
  • 0.0172
  • 0.01287
Potential incidence of disease due to PM emissions (PM) 2
  • 1.501E-7
  • 6.618E-9
  • 7.27E-10
  • 8.871E-9
Potential Soil quality index (SQP) 2
  • 20.47
  • 0.9984
  • 0.8973
  • 1.131
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.92E-8
  • 1.168E-9
  • 6.56E-10
  • 2.245E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.425E-9
  • 0
  • 1.9E-11
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 60.85
  • 1.272
  • 0.772
  • 1.919