Close Go back Collapse all sections
Process Data set: PEX-AL-LRT 1x630+50 72kV (en) en

Key Data Set Information
Location SE
Geographical representativeness description Denmark
Reference year 2025
Name
PEX-AL-LRT 1x630+50 72kV
Technical purpose of product or process Longitudinal and radial water blocked 1-core utility cable with aluminium conductor, copper wire screen, laminated alu foil and UV-stabilized outer sheath.The cable is triple-extruded and halogen-free. Suitable for installation in pipes or directly in soil. 800mm²and 1000mm² is delivered with HDPE sheath. Conductor material Aluminium Conductor surface Bare Inner semi-conducting layer Yes Coreinsulation material XLPE Outer semi-conducting layer Yes Longitudinal water blocking cable Yes Radial water blocking cable Yes Screen construction Wirescreen and counterhelix tape Screen material Copper, bare Material outer sheath MDPE Laminated sheath Yes
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-02-13 - 2030-02-13
Technological representativeness
Technology description including background system PEX-AL-LRT 1x630+50 72kV SAP code 20132791 STANDARDS APPLIED: IEC 60840 Test method and requirements for powercables with extruded insulation for36- 170 kV REACH Regulation concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals. ROHS RoHScompliance- restriction of hazardous substances directive

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 79.63
  • 0.1885
  • 10.2
  • 0.07708
  • 1.163
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.06105
  • 0
  • 0
  • 0.04625
  • 0.006715
  • 0.04538
  • -56.37
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 79.63
  • 0.1885
  • 10.2
  • 0.07708
  • 1.163
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.06105
  • 0
  • 0
  • 0.04625
  • 0.006715
  • 0.04538
  • -56.37
Input
  • 489.5
  • 11.45
  • 21.54
  • 5.462
  • 6.947
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07109
  • 0
  • 0
  • 3.277
  • 0.2143
  • 0.4959
  • -114.9
Input
  • 94.1
  • 0
  • 0
  • 0
  • 0.07008
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -87.04
  • 0
  • 0
Input
  • 583.6
  • 11.45
  • 21.54
  • 5.462
  • 7.017
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07109
  • 0
  • 0
  • 3.277
  • -86.82
  • 0.4959
  • -114.9
Input
  • 0.3936
  • 0
  • 0
  • 0
  • 0.004326
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02326
Input
  • 0.6319
  • 0.005491
  • 0.03991
  • 0.002759
  • 0.00847
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002295
  • 0
  • 0
  • 0.001655
  • 0.0001833
  • 0.000945
  • -0.01704
Input
  • 0.1848
  • 0.02931
  • 0.1276
  • 0.009849
  • 0.004894
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001215
  • 0
  • 0
  • 0.005909
  • 0
  • 0.003981
  • -0.8642
Input
  • 0.5045
  • 0.001369
  • 0.02454
  • 0.0005752
  • 0.007019
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002265
  • 0
  • 0
  • 0.0003451
  • 0.0006929
  • 0.0006278
  • -0.2415
Output
  • 0.2985
  • 0.0006968
  • 0.1008
  • 0.0002786
  • 0.006017
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000009397
  • 0
  • 0
  • 0.0001671
  • 0
  • 0.0587
  • 0.03599
Output
  • 8.671
  • 0.4969
  • 0.1606
  • 0.2611
  • 0.1486
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004338
  • 0
  • 0
  • 0.1566
  • 0
  • 1.795
  • -2.649
Output
  • 0.001216
  • 0.00007669
  • 0.0003207
  • 0.00003724
  • 0.000022
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.239E-7
  • 0
  • 0
  • 0.00002235
  • 0
  • 0.000003357
  • -0.0004704
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.003924
  • 0
  • 0.01905
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.521
  • 0.00009395
  • -0.0009102
Output
  • 0
  • 0
  • 0.4079
  • 0
  • 0.02207
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.057
  • 0.000002298
  • -0.0001198
Output
  • 0
  • 0
  • 0.2397
  • 0
  • 0.03513
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.021
  • 0.0001491
  • -0.0002937
Output
  • 0
  • 0
  • 3.627
  • 0
  • 0.5314
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 30.58
  • 0.002255
  • -0.004443

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 576.9
  • 11.45
  • 21.49
  • 5.462
  • 8.33
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.07107
  • 0
  • 0
  • 3.277
  • 0.2141
  • 0.4959
  • -114.9
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00153
  • 0.00001415
  • 0.000007594
  • 0.000009811
  • 0.00001726
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.883E-8
  • 0
  • 0
  • 0.000005887
  • 1.187E-7
  • 1.685E-7
  • -0.00006304
Acidification potential, Accumulated Exceedance (AP)
  • 0.354
  • 0.006995
  • 0.001364
  • 0.001481
  • 0.004443
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002199
  • 0
  • 0
  • 0.0008884
  • 0.0004045
  • 0.0001684
  • -0.07426
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.369
  • 0.000357
  • 0.0501
  • 0.0001477
  • 0.005419
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005682
  • 0
  • 0
  • 0.00008861
  • 0.01597
  • 0.007658
  • -0.04108
Global Warming Potential - fossil fuels (GWP-fossil)
  • 44.1
  • 0.7939
  • 0.4135
  • 0.3622
  • 0.6479
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005482
  • 0
  • 0
  • 0.2173
  • 3.131
  • 0.1323
  • -9.034
Global Warming Potential - total (GWP-total)
  • 44.71
  • 0.7946
  • 0.4754
  • 0.3625
  • 0.6566
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005547
  • 0
  • 0
  • 0.2175
  • 3.147
  • 0.1399
  • -9.248
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.2413
  • 0.0003328
  • 0.01176
  • 0.0001266
  • 0.003312
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000007382
  • 0
  • 0
  • 0.00007597
  • 0.000004073
  • 0.000006641
  • -0.173
  • 44.49
  • 0.7946
  • 0.4667
  • 0.3625
  • 0.6537
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00767
  • 0
  • 0
  • 0.2175
  • 3.143
  • 0.1422
  • -8.792
Eutrophication potential - freshwater (EP-freshwater)
  • 0.002256
  • 0.000007201
  • 0.00001316
  • 0.000002845
  • 0.00002681
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.488E-7
  • 0
  • 0
  • 0.000001707
  • 2.551E-7
  • 3.694E-7
  • -0.0004452
Eutrophication potential - marine (EP-marine)
  • 0.04561
  • 0.002218
  • 0.0003451
  • 0.0004391
  • 0.0006195
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000003698
  • 0
  • 0
  • 0.0002635
  • 0.000194
  • 0.0001966
  • -0.008526
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.5256
  • 0.02449
  • 0.003368
  • 0.004856
  • 0.007026
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00005279
  • 0
  • 0
  • 0.002914
  • 0.002092
  • 0.0006701
  • -0.09621
Photochemical Ozone Creation Potential (POCP)
  • 0.1601
  • 0.006804
  • 0.0008083
  • 0.001487
  • 0.002179
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001125
  • 0
  • 0
  • 0.0008921
  • 0.0005011
  • 0.0002176
  • -0.03157
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000002233
  • 1.696E-7
  • 9.331E-8
  • 8.258E-8
  • 3.43E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.86E-10
  • 0
  • 0
  • 4.955E-8
  • 2.572E-9
  • 6.358E-9
  • -0.01292
Water (user) deprivation potential (WDP)
  • 7163
  • 9.256
  • 2149
  • 5.21
  • 123.6
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.104
  • 0
  • 0
  • 3.126
  • 0.5415
  • 8.375
  • -5058

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.236
  • 0.0494
  • 0.7267
  • 0.02387
  • 0.02737
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0003476
  • 0
  • 0
  • 0.01432
  • 0.0003752
  • 0.00284
  • -0.5027
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000003112
  • 6.116E-8
  • 1.053E-8
  • 2.608E-8
  • 4.077E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.08E-10
  • 0
  • 0
  • 1.565E-8
  • 1.606E-9
  • 3.109E-9
  • -7.284E-7
Potential Soil quality index (SQP) 2
  • 102.3
  • 8.198
  • 9.66
  • 3.766
  • 1.593
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1168
  • 0
  • 0
  • 2.259
  • 0.02697
  • 1.375
  • -19.46
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002566
  • 9.739E-9
  • 1.01E-8
  • 4.346E-9
  • 2.831E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.3E-11
  • 0
  • 0
  • 2.608E-9
  • 2.84E-9
  • 6.04E-10
  • -4.207E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 8.116E-8
  • 0
  • 4.05E-10
  • 0
  • 9.85E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2E-12
  • 0
  • 0
  • 0
  • 7.3E-11
  • 2.8E-11
  • -2.421E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2221
  • 8.891
  • 12.61
  • 4.023
  • 30.15
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1265
  • 0
  • 0
  • 2.414
  • 0.8329
  • 439.6
  • -269.1