Close Go back Collapse all sections
Process Data set: Envistar Flex 060 with counter-flow heat exchanger and controls (en) en

Key Data Set Information
Location SE
Geographical representativeness description Europe
Reference year 2025
Name
Envistar Flex 060 with counter-flow heat exchanger and controls
Technical purpose of product or process Air Handling Unit (AHU) for non residential building. Envistar Flex air handling unit for non residential buildings. Bi-directional including counter-flow heat exchanger and integrated controls, damper and LPHW coil.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-02-13 - 2030-02-13
Technological representativeness
Technology description including background system According to to printout from IVP Designer (selection program).

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 7944
  • 3.321
  • 0
  • 1.069
  • 32.29
  • 3.549
  • -3627
Input
  • 2.767
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 7947
  • 3.321
  • 0
  • 1.069
  • 32.29
  • 3.549
  • -3627
Input
  • 2.608E+4
  • 248.9
  • 0
  • 74.69
  • 182.1
  • 19.27
  • -1.121E+4
Input
  • 536.3
  • 0
  • 0
  • 0
  • -327.7
  • 0
  • 0
Input
  • 2.662E+4
  • 248.9
  • 0
  • 74.69
  • -145.7
  • 19.27
  • -1.121E+4
Input
  • 116
  • 0
  • 0
  • 0
  • 0.0001032
  • 0.06163
  • 0.9594
Input
  • 41.25
  • 0.1174
  • 0
  • 0.03825
  • 0.6853
  • 0.02797
  • 3.448
Input
  • 377.6
  • 0.406
  • 0
  • 0.1368
  • -0.002774
  • 0.6898
  • 141.2
Input
  • 58.63
  • 0.02757
  • 0
  • 0.007987
  • 0.1874
  • 0.02269
  • -19.53
Output
  • 15.93
  • 0.01327
  • 0
  • 0.003852
  • 0.001435
  • 3.383
  • 2.219
Output
  • 620.2
  • 17.44
  • 0
  • 3.632
  • 29.55
  • 33.23
  • -279.5
Output
  • 0.09245
  • 0.001698
  • 0
  • 0.0005088
  • 0.00007189
  • 0.000003224
  • -0.04027
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 48.25
  • 0
  • 0
  • 0
  • 289.4
  • 0.00008948
  • -0.05076
Output
  • 15.74
  • 0
  • 0
  • 0
  • 28.11
  • 0.000002569
  • -0.00657
Output
  • 9.277
  • 0
  • 0
  • 0
  • 0.6809
  • 0.00009568
  • -0.02084
Output
  • 140.4
  • 0
  • 0
  • 0
  • 10.3
  • 0.001448
  • -0.3153

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2.649E+4
  • 248.9
  • 0
  • 74.68
  • 181
  • 19.25
  • -1.121E+4
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.7356
  • 0.0003529
  • 0
  • 0.0001364
  • 0.0001632
  • 0.000008483
  • -0.08208
Acidification potential, Accumulated Exceedance (AP)
  • 19.27
  • 0.04844
  • 0
  • 0.0142
  • 0.0663
  • 0.007596
  • -9.372
Global Warming Potential - biogenic (GWP-biogenic)
  • 13.52
  • 0.006673
  • 0
  • 0.002044
  • 0.1012
  • 0.00178
  • -3.636
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2124
  • 15.82
  • 0
  • 4.939
  • 65.79
  • 2.373
  • -925.6
Global Warming Potential - total (GWP-total)
  • 2145
  • 15.83
  • 0
  • 4.943
  • 65.91
  • 2.38
  • -943.5
Global Warming Potential - land use and land use change (GWP-luluc)
  • 6.774
  • 0.005191
  • 0
  • 0.001758
  • 0.01399
  • 0.005581
  • -14.23
  • 2142
  • 15.83
  • 0
  • 4.943
  • 55.26
  • 2.458
  • -972.6
Eutrophication potential - freshwater (EP-freshwater)
  • 0.1589
  • 0.0001261
  • 0
  • 0.00003946
  • 0.0009782
  • 0.00004425
  • -0.05804
Eutrophication potential - marine (EP-marine)
  • 2.513
  • 0.01017
  • 0
  • 0.002809
  • 0.01428
  • 0.002073
  • -0.9523
Eutrophication potential - terrestrial (EP-terrestrial)
  • 40.57
  • 0.1136
  • 0
  • 0.03142
  • 0.1591
  • 0.02242
  • -10.92
Photochemical Ozone Creation Potential (POCP)
  • 9.417
  • 0.04415
  • 0
  • 0.01204
  • 0.04439
  • 0.007608
  • -3.736
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.0001705
  • 0.000003709
  • 0
  • 0.000001119
  • 0.000004809
  • 1.807E-7
  • -0.04185
Water (user) deprivation potential (WDP)
  • 2.671E+5
  • 212.7
  • 0
  • 72.24
  • 781
  • 242.8
  • -4.193E+5

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 106.7
  • 1.088
  • 0
  • 0.3264
  • 0.8397
  • 0.07769
  • -42.97
Potential incidence of disease due to PM emissions (PM) 2
  • 0.0001802
  • 0.000001232
  • 0
  • 3.024E-7
  • 9.397E-7
  • 1.064E-7
  • -0.00007034
Potential Soil quality index (SQP) 2
  • 1.188E+4
  • 236.4
  • 0
  • 52.24
  • 70.75
  • 54.64
  • -7.5E+2
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.0001274
  • 1.872E-7
  • 0
  • 6.048E-8
  • 0.000003105
  • 5.293E-7
  • -0.00002255
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.000007615
  • 0
  • 0
  • 0
  • 8.786E-8
  • 1.083E-8
  • -0.000002701
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1.254E+5
  • 183.1
  • 0
  • 55.36
  • 913.3
  • 3955
  • -4.62E+4