Close Go back Collapse all sections
Process Data set: ÖLFLEX® SERVO 2YSLCYK-JB 3X2,5+3G0,5 BK (en) en

Key Data Set Information
Location FR
Geographical representativeness description Norway
Reference year 2025
Name
ÖLFLEX® SERVO 2YSLCYK-JB 3X2,5+3G0,5 BK
Technical purpose of product or process ÖLFLEX SERVO 2YSLCYK-JB are double shielded low capacitance cables of flexible design, with PVC sheath and PE core insulation. They are suitable for frequency converters operated by three-phase current motors. They are also suitable for use in dry, damp or wet areas. They are largely resistant to acids, alkalis and certain oils at room temperature. They are suitable for occasional, non-automated movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. The earthing concept for this version with the protective conductor splitted in thirds is composed of the defined cross-sections of the protective conductors and the screening braid. This design avoids all cable-relevant parts from high frequency discharge currents, which may damage motor bearings especially at high frequencies and long cable lengths. This design also improves EMC noise situation of the whole drive system. Additionally, due to the design the frequency converter system is burdened with lower capacitive reactive power compared to PVC insulated cables. Application range: Connection cable between frequency converter and motor, paper industry, chemical industry, heavy industry. Design based on DIN VDE 0276-603 / HD 603 S1 + A3 DIN 57250-1 resp. VDE 0250-1 Certification EN 13501-6 and EN 50575 Classification of fire behaviour (article/dimension range see www.lappkabel.com/cpr) Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. EN 60228, class 5 Insulation PE compound acc. to EN 50290-2-23, table 1, column L/MD Core identification code acc. to VDE 0293-308 resp. HD 308 S2 Stranding 3+3 cores twisted concentrically, protective conductor divided into three positioned in the gusset Screen double screening with aluminium-coated plastic foil (metal-side outwards) and braid of tinned copper wires, braid coverage min. 70% (nominal value) Outer sheath PVC sheath, acc. to EN 50363-4-1, UV resistant, cold flexible, outdoor use colour: black, similar RAL 9005
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.002067083335 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-07-31 - 2030-07-31
Technological representativeness
Technology description including background system Electrical properties at 20 °C Specific volume resistivity > 20 G O x cm Transfer impedance max. 250 mO/m (at 30 MHz) Nominal voltage 600/1000 V Test voltage C/C: 4000 V C/S: 4000 V Mechanical and thermal properties Minimum bending radius occasional flexing: 15 x outer diameter fixed installation: 4 x outer diameter Temperature range occasional flexing: -15 °C up to +70 °C max. conductor temperature fixed installation: -40 °C up to +70 °C max. conductor temperature Flammability flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 UV resistance acc. to EN 50525-1 cable with black sheath are suitable for permanent outdoor use. Tests acc. to IEC 60811 resp. EN 60811, VDE 0472, EN 50395, EN 50396 General requirements These cables are conform to the EU-Directive 2014/35 EU (Low Voltage Directive). A part of these cables (see www.lappkabel.com/cpr) are classified in accordance with the EU-Regulation no. 305/2011 (CPR). Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS).

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 2.285
  • 0.005221
  • 0.2514
  • 0.008833
  • 0.05405
  • 0
  • 0.0006611
  • 0.01279
  • 0.003977
  • -0.9755
Input
  • 0.0694
  • 0
  • 0
  • 0
  • -0.06593
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 2.354
  • 0.005221
  • 0.2514
  • 0.008833
  • -0.01188
  • 0
  • 0.0006611
  • 0.01279
  • 0.003977
  • -0.9755
Input
  • 11.22
  • 0.3647
  • 1.654
  • 0.7022
  • 0.3234
  • 0
  • 0.04619
  • 0.1002
  • 0.03908
  • -1.668
Input
  • 1.635
  • 0
  • 0
  • 0
  • 0.02394
  • 0
  • 0
  • -2.086
  • 0
  • 0
Input
  • 12.85
  • 0.3647
  • 1.654
  • 0.7022
  • 0.3473
  • 0
  • 0.04619
  • -1.986
  • 0.03908
  • -1.668
Input
  • 0.02445
  • 0
  • 0
  • 0
  • 0.0004276
  • 0
  • 0
  • 0
  • 0.000001153
  • 0.05291
Input
  • 0.05926
  • 0.0001868
  • 0.001814
  • 0.000309
  • 0.00113
  • 0
  • 0.00002365
  • 0.0002311
  • 0.00008551
  • 0.004973
Input
  • 0.00173
  • 0.0006678
  • 0.004628
  • 0.001036
  • 0.0003194
  • 0
  • 0.00008457
  • 0
  • 0.000147
  • -0.008576
Input
  • 0.01508
  • 0.000039
  • 0.001526
  • 0.0000799
  • 0.0003896
  • 0
  • 0.000004939
  • 0.002397
  • 0.00004713
  • -0.004818
Output
  • 0.008649
  • 0.00001881
  • 0.003326
  • 0.00003842
  • 0.0003734
  • 0
  • 0.000002382
  • 0
  • 0.002705
  • -0.002051
Output
  • 0.3107
  • 0.01774
  • 0.01596
  • 0.06103
  • 0.01467
  • 0
  • 0.002246
  • 0
  • 0.1125
  • -0.0884
Output
  • 0.00004485
  • 0.000002484
  • 0.00002099
  • 0.000004794
  • 0.000002021
  • 0
  • 3.146E-7
  • 0
  • 2.274E-7
  • -0.000002093
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01209
  • 0
  • 0.002015
  • 0
  • 0
  • 0.0864
  • 0.00000435
  • -0.002071
Output
  • 0
  • 0
  • 0.01426
  • 0
  • 0.005672
  • 0
  • 0
  • 0.038
  • 1.064E-7
  • -0.0002726
Output
  • 0
  • 0
  • 0.00873
  • 0
  • 0.004423
  • 0
  • 0
  • 0.03887
  • 0.000006902
  • -0.000668
Output
  • 0
  • 0
  • 0.1321
  • 0
  • 0.06692
  • 0
  • 0
  • 0.5881
  • 0.0001044
  • -0.01011

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 12.85
  • 0.3647
  • 1.654
  • 0.7022
  • 0.3698
  • 0
  • 0.04618
  • 0.1002
  • 0.03908
  • -1.668
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0003537
  • 6.663E-7
  • 3.713E-7
  • 7.703E-7
  • 0.000005172
  • 0
  • 8.437E-8
  • 1.604E-7
  • 1.447E-8
  • -0.0001701
Acidification potential, Accumulated Exceedance (AP)
  • 0.03372
  • 0.00006932
  • 0.00008092
  • 0.0001392
  • 0.0005775
  • 0
  • 0.000008778
  • 0.00004403
  • 0.00001415
  • -0.0304
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.007128
  • 0.000009983
  • 0.001574
  • 0.00001852
  • 0.007532
  • 0
  • 0.000001264
  • 0.00003101
  • 0.000001188
  • -0.0008483
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.8466
  • 0.02412
  • 0.02351
  • 0.04323
  • 0.0201
  • 0
  • 0.003054
  • 0.07613
  • 0.007802
  • -0.1845
Global Warming Potential - total (GWP-total)
  • 0.8546
  • 0.02414
  • 0.0251
  • 0.04326
  • 0.02765
  • 0
  • 0.003057
  • 0.07617
  • 0.007804
  • -0.1857
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0008668
  • 0.000008585
  • 0.00001437
  • 0.00001317
  • 0.00001726
  • 0
  • 0.000001087
  • 0.000005948
  • 6.052E-7
  • -0.0003187
  • 0.8611
  • 0.02414
  • 0.02478
  • 0.04326
  • 0.02036
  • 0
  • 0.003057
  • 0.07637
  • 0.006672
  • -0.08958
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0002751
  • 1.927E-7
  • 5.799E-7
  • 3.44E-7
  • 0.000004661
  • 0
  • 2.44E-8
  • 2.241E-7
  • 4.046E-8
  • -0.000205
Eutrophication potential - marine (EP-marine)
  • 0.002345
  • 0.00001372
  • 0.00001773
  • 0.00003048
  • 0.00004274
  • 0
  • 0.000001737
  • 0.00001075
  • 0.00001055
  • -0.001257
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.03409
  • 0.0001534
  • 0.0001678
  • 0.00034
  • 0.0006032
  • 0
  • 0.00001943
  • 0.0001153
  • 0.00005415
  • -0.01945
Photochemical Ozone Creation Potential (POCP)
  • 0.008576
  • 0.00005877
  • 0.0000467
  • 0.0001335
  • 0.0001556
  • 0
  • 0.000007443
  • 0.00003262
  • 0.00001633
  • -0.005282
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.438E-7
  • 5.463E-9
  • 7.578E-9
  • 1.042E-8
  • 4.224E-9
  • 0
  • 6.92E-10
  • 2.502E-9
  • 4.76E-10
  • -0.0002705
Water (user) deprivation potential (WDP)
  • 51.41
  • 0.3527
  • 25.02
  • 0.5383
  • 2.202
  • 0
  • 0.04467
  • 2.045
  • 0.7386
  • 9.238

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.04891
  • 0.001594
  • 0.01631
  • 0.003069
  • 0.001805
  • 0
  • 0.0002019
  • 0.0004867
  • 0.0002288
  • -0.002346
Potential incidence of disease due to PM emissions (PM) 2
  • 9.737E-8
  • 1.476E-9
  • 4.91E-10
  • 3.971E-9
  • 1.838E-9
  • 0
  • 1.87E-10
  • 2.86E-10
  • 2.24E-10
  • -6.256E-8
Potential Soil quality index (SQP) 2
  • 8.932
  • 0.2551
  • 0.09679
  • 0.8049
  • 0.2101
  • 0
  • 0.0323
  • 0.03648
  • 0.1041
  • -3.899
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 5.463E-7
  • 2.95E-10
  • 4.46E-10
  • 4.96E-10
  • 9.144E-9
  • 0
  • 3.7E-11
  • 1.13E-9
  • 8.8E-11
  • -3.381E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 7.24E-9
  • 0
  • 1.8E-11
  • 0
  • 1.22E-10
  • 0
  • 0
  • 1.1E-11
  • 3E-12
  • -3.946E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 407.3
  • 0.2703
  • 0.594
  • 0.5134
  • 7.397
  • 0
  • 0.03424
  • 4.801
  • 35.7
  • -279.6