Close Go back Collapse all sections
Process Data set: Prio Silent XP (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe
Reference year 2025
Name
Prio Silent XP
Use advice for data set For A2 an average mode of transport of EURO5 truck is declared.
Technical purpose of product or process The Prio Silent® XP fan is a circular duct fan with a silencer and a mounting bracket integrated in the casing. The product is acoustically and thermally isolated and the casing has a high resistance against oil and chemicals. The product casing is made from a material that is shock absorbing and easy to clean. The product is intended for continuous operation in ambient temperatures of between -25°C and +55°C.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-10-13 - 2030-10-13
Technological representativeness
Technology description including background system Energy performance must be calculated using realistic project specific operating conditions. Complete and project specific product specification including all relevant technical data and energy performance can be generated using our online product selection software. Please refer to the Systemair website for more information. EPD data is provided for the Prio Silent XP 250EC. The Conversion factor is based on the GWPtot (A1-A3) from the size specific EPDs.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 31.73
  • 0.0769
  • 0.0006106
  • 0.01282
  • 0.01926
  • 0.01689
  • -25.03
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 31.73
  • 0.0769
  • 0.0006106
  • 0.01282
  • 0.01926
  • 0.01689
  • -25.03
Input
  • 352.9
  • 5.372
  • 0.1129
  • 0.8953
  • 0.2701
  • 0.386
  • -35.66
Input
  • 89.19
  • 0
  • 0
  • 0
  • -89.19
  • 0
  • 0
Input
  • 442.1
  • 5.372
  • 0.1129
  • 0.8953
  • -88.92
  • 0.386
  • -35.66
Input
  • 1.895
  • 0
  • 0.00005543
  • 0
  • 0.00001918
  • 0.000001719
  • 0.07442
Input
  • 2.247
  • 0.002751
  • 0.00001502
  • 0.0004585
  • 0.0004467
  • 0.0003581
  • 0.06447
Input
  • 2.524
  • 0.009836
  • 0.000221
  • 0.001639
  • 0.0000204
  • 0.00541
  • 0.8346
Input
  • 0.2756
  • 0.0005745
  • 0.00000581
  • 0.00009575
  • 0.0007452
  • 0.0004716
  • -0.06214
Output
  • 0.1387
  • 0.000277
  • 0.000003323
  • 0.00004617
  • 0.000002223
  • 0.03437
  • -0.006743
Output
  • 5.285
  • 0.2612
  • 0.0001336
  • 0.04354
  • 0.00007211
  • 1.727
  • -1.264
Output
  • 0.0009229
  • 0.00003659
  • 7.838E-7
  • 0.000006099
  • 2.254E-7
  • 0.000002229
  • -0.00007766
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.5588
  • 0
  • 0.00005443
  • 0
  • 3.155
  • 0.0001237
  • -0.002912
Output
  • 0.09
  • 0
  • 1.688E-7
  • 0
  • 1.362
  • 0.000003034
  • -0.0003835
Output
  • 0.06291
  • 0
  • 5.786E-7
  • 0
  • 2.213
  • 0.0001939
  • -0.0009395
Output
  • 0.9518
  • 0
  • 0.000008754
  • 0
  • 33.47
  • 0.002934
  • -0.01421

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 441.8
  • 5.372
  • 0.1129
  • 0.8953
  • 0.2701
  • 0.386
  • -35.66
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.005393
  • 0.000009814
  • 1.258E-8
  • 0.000001636
  • 1.426E-7
  • 1.306E-7
  • -0.0002692
Acidification potential, Accumulated Exceedance (AP)
  • 0.2243
  • 0.001021
  • 0.0000858
  • 0.0001702
  • 0.0004741
  • 0.0001293
  • -0.06146
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.1813
  • 0.000147
  • 0.000001538
  • 0.00002451
  • 0.00003592
  • 0.00001694
  • -0.008322
Global Warming Potential - fossil fuels (GWP-fossil)
  • 24.11
  • 0.3553
  • 0.008202
  • 0.05921
  • 3.472
  • 0.1594
  • -3.443
Global Warming Potential - total (GWP-total)
  • 24.33
  • 0.3555
  • 0.008204
  • 0.05926
  • 3.472
  • 0.1595
  • -3.483
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.03123
  • 0.0001265
  • 6.464E-7
  • 0.00002108
  • 0.000005572
  • 0.00000377
  • -0.03162
  • 24.36
  • 0.3555
  • 0.008204
  • 0.05926
  • 3.471
  • 0.1595
  • -4.15
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001915
  • 0.000002838
  • 2.986E-8
  • 4.731E-7
  • 3.46E-7
  • 1.865E-7
  • -0.0004606
Eutrophication potential - marine (EP-marine)
  • 0.02472
  • 0.000202
  • 0.00003787
  • 0.00003367
  • 0.0002289
  • 0.0002078
  • -0.005138
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.403
  • 0.00226
  • 0.0004155
  • 0.0003766
  • 0.00245
  • 0.0005118
  • -0.06294
Photochemical Ozone Creation Potential (POCP)
  • 0.09738
  • 0.0008656
  • 0.0001142
  • 0.0001443
  • 0.0005888
  • 0.0001788
  • -0.02164
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001561
  • 8.047E-8
  • 1.773E-9
  • 1.341E-8
  • 3.021E-9
  • 5.272E-9
  • -0.01414
Water (user) deprivation potential (WDP)
  • 1545
  • 5.196
  • 0.02398
  • 0.8659
  • 3.113
  • 3.039
  • -651.3

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.9526
  • 0.02348
  • 0.0004837
  • 0.003913
  • 0.0008032
  • 0.001843
  • -0.08388
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000001639
  • 2.175E-8
  • 2.27E-9
  • 3.625E-9
  • 2.188E-9
  • 2.555E-9
  • -4.144E-7
Potential Soil quality index (SQP) 2
  • 127.3
  • 3.757
  • 0.01433
  • 0.6262
  • 0.05002
  • 1.431
  • -24.77
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001852
  • 4.35E-9
  • 5.6E-11
  • 7.25E-10
  • 3.051E-9
  • 4.464E-8
  • -3.451E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 8.487E-8
  • 0
  • 0
  • 0
  • 8.2E-11
  • 6.56E-10
  • -1.736E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1531
  • 3.982
  • 0.06169
  • 0.6637
  • 0.8148
  • 7.448
  • -523.8