Close Go back Collapse all sections
Process Data set: AXALJ-TT E Path 3x300/50 ALCL 24kV (en) en

Key Data Set Information
Location SE
Geographical representativeness description Sweden
Reference year 2024
Name
AXALJ-TT E Path 3x300/50 ALCL 24kV
Technical purpose of product or process Totally water sealed three core power cable with corrosion protected aluminium screen. The cable is primarily designed for ploughing down in ground, but thanks to its robust design can also handle the stresses from installation in shallow lakes with limited currents. Radially water sealed by an aluminium laminate bonded to the outer sheath and longitudinally water sealed with swellable tapes. The screen is made up of circular corrosion protected aluminium wires that are covered with a semiconductive. By using the two strong ripcords stripping of the jacket becomes easier and safer for both man and cable. Conductor design Stranded, round, compacted aluminum class 2, longitudinal water sealed Conductor material Aluminum Inner semi-conducting layer Yes Core insulation material XLPE Outer semi-conducting layer Yes Screen construction Metal tape and wire Material outer sheath MDPE Laminated sheath Yes Longitudinal water blocking screen Yes Rip cord Yes STANDARDS, CERTIFICATIONS AND APPROVALS: SS 424 14 16 Construction standard 12-36 kV CENELEC HD 620 Part 10 Section M Harmonized construction and testing standard IEC 60228 Construction standard
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-01-09" - "2029-01-09"
Technological representativeness
Technology description including background system AXALJ-TT E Path 3x300/50 ALCL 24kV SAP code: 20424655 External art. code: 0087340 STANDARDS, CERTIFICATIONS AND APPROVALS: SS 424 14 16 Construction standard 12-36 kV CENELEC HD 620 Part 10 Section M Harmonized construction and testing standard IEC 60228 Construction standard

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 108.5
  • 0.2718
  • 12.69
  • 0.09581
  • 2.433
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2998
  • 0
  • 0
  • 0.0573
  • 0.01313
  • 0.06053
  • -79.32
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 108.5
  • 0.2718
  • 12.69
  • 0.09581
  • 2.433
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2998
  • 0
  • 0
  • 0.0573
  • 0.01313
  • 0.06053
  • -79.32
Input
  • 656.1
  • 18.88
  • 27.04
  • 7.612
  • 14.29
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6249
  • 0
  • 0
  • 4.061
  • 0.3175
  • 0.6948
  • -171
Input
  • 118
  • 0
  • 0
  • 0
  • 0.1656
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -109.7
  • 0
  • 0
Input
  • 774
  • 18.88
  • 27.04
  • 7.612
  • 14.45
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6249
  • 0
  • 0
  • 4.061
  • -109.4
  • 0.6949
  • -171
Input
  • 1.294
  • 0
  • 0
  • 0
  • 0.02597
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004202
  • 0
Input
  • 0.4292
  • 0.007509
  • 0.05023
  • 0.003351
  • 0.009876
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001162
  • 0
  • 0
  • 0.002051
  • 0.000316
  • 0.001307
  • -0.02808
Input
  • 0.2313
  • 0.04761
  • 0.1585
  • 0.01123
  • 0.009989
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00367
  • 0
  • 0
  • 0.007321
  • 0
  • 0.04387
  • -1.004
Input
  • 0.6519
  • 0.002075
  • 0.02954
  • 0.0008668
  • 0.01375
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0006808
  • 0
  • 0
  • 0.0004276
  • 0.001711
  • 0.0008148
  • -0.3545
Output
  • 0.4278
  • 0.001119
  • 0.1255
  • 0.0004167
  • 0.01896
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003262
  • 0
  • 0
  • 0.0002071
  • 0
  • 0.3928
  • 0.05557
Output
  • 11.83
  • 0.8458
  • 0.2002
  • 0.6622
  • 0.3133
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002059
  • 0
  • 0
  • 0.1941
  • 0
  • 1.957
  • -3.911
Output
  • 0.001547
  • 0.0001272
  • 0.0003999
  • 0.00005197
  • 0.00004313
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000009402
  • 0
  • 0
  • 0.00002769
  • 0
  • 0.000004569
  • -0.0007027
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.004862
  • 0
  • 0.03842
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.916
  • 0.00009055
  • 0
Output
  • 0
  • 0
  • 0.5081
  • 0
  • 0.03657
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.321
  • 0.0001058
  • 0
Output
  • 0
  • 0
  • 0.2986
  • 0
  • 0.05363
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.382
  • 0.001052
  • 0
Output
  • 0
  • 0
  • 4.518
  • 0
  • 0.8114
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 36.03
  • 0.01592
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 739.3
  • 18.88
  • 26.98
  • 7.612
  • 15.95
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6236
  • 0
  • 0
  • 4.06
  • 0.3175
  • 0.6948
  • -171
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0009751
  • 0.00001635
  • 0.00000947
  • 0.000008357
  • 0.00002033
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.13E-7
  • 0
  • 0
  • 0.000007294
  • 2.075E-7
  • 2.878E-7
  • 0.00001823
Acidification potential, Accumulated Exceedance (AP)
  • 0.3923
  • 0.01945
  • 0.001926
  • 0.002057
  • 0.008352
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003465
  • 0
  • 0
  • 0.001101
  • 0.0005614
  • 0.0002453
  • -0.09123
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.4621
  • 0.0005577
  • 0.06241
  • 0.0002008
  • 0.01051
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001081
  • 0
  • 0
  • 0.0001098
  • 0.00004422
  • 0.00002194
  • -0.06118
Global Warming Potential - fossil fuels (GWP-fossil)
  • 61.76
  • 1.338
  • 0.5391
  • 0.4894
  • 1.364
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005321
  • 0
  • 0
  • 0.2693
  • 3.695
  • 0.1411
  • -13.42
Global Warming Potential - total (GWP-total)
  • 62.58
  • 1.339
  • 0.6161
  • 0.4897
  • 1.382
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005775
  • 0
  • 0
  • 0.2695
  • 3.695
  • 0.1412
  • -13.74
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.3547
  • 0.0006339
  • 0.01459
  • 0.0001429
  • 0.007403
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0003456
  • 0
  • 0
  • 0.00009413
  • 0.000007401
  • 0.00001024
  • -0.2583
  • 62.55
  • 1.339
  • 0.6081
  • 0.4897
  • 1.382
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005768
  • 0
  • 0
  • 0.2695
  • 3.695
  • 0.1457
  • -13.12
Eutrophication potential - freshwater (EP-freshwater)
  • 0.002217
  • 0.00001081
  • 0.00001657
  • 0.000003732
  • 0.00004502
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.598E-7
  • 0
  • 0
  • 0.000002115
  • 4.054E-7
  • 6.32E-7
  • -0.0005296
Eutrophication potential - marine (EP-marine)
  • 0.05857
  • 0.005504
  • 0.0004614
  • 0.0006185
  • 0.001318
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005901
  • 0
  • 0
  • 0.0003264
  • 0.0002691
  • 0.0001937
  • -0.01185
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.6442
  • 0.06099
  • 0.004544
  • 0.006841
  • 0.01447
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00007768
  • 0
  • 0
  • 0.00361
  • 0.002848
  • 0.0009451
  • -0.1304
Photochemical Ozone Creation Potential (POCP)
  • 0.2004
  • 0.01648
  • 0.001115
  • 0.0022
  • 0.004443
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000177
  • 0
  • 0
  • 0.001105
  • 0.0006839
  • 0.0002882
  • -0.04359
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000003082
  • 2.846E-7
  • 1.204E-7
  • 1.131E-7
  • 7.34E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.609E-9
  • 0
  • 0
  • 6.139E-8
  • 4.31E-9
  • 8.648E-9
  • -0.01522
Water (user) deprivation potential (WDP)
  • 1.008E+4
  • 11.77
  • 2666
  • 5.839
  • 255.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 63.28
  • 0
  • 0
  • 3.873
  • 1.435
  • 11.11
  • -7612

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.539
  • 0.0812
  • 0.9029
  • 0.03327
  • 0.05154
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02138
  • 0
  • 0
  • 0.01775
  • 0.0006559
  • 0.003855
  • -0.7503
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000004258
  • 8.592E-8
  • 1.495E-8
  • 4.308E-8
  • 8.853E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.5E-10
  • 0
  • 0
  • 1.939E-8
  • 2.306E-9
  • 4.031E-9
  • -0.000001028
Potential Soil quality index (SQP) 2
  • 122.4
  • 13.6
  • 12.17
  • 8.732
  • 3.226
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2761
  • 0
  • 0
  • 2.799
  • 0.04737
  • 1.853
  • -21.41
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001533
  • 1.244E-8
  • 1.266E-8
  • 5.385E-9
  • 3.146E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.28E-10
  • 0
  • 0
  • 3.231E-9
  • 4.989E-9
  • 1.312E-9
  • -4.054E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.023E-8
  • 0
  • 5.35E-10
  • 0
  • 1.819E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9E-12
  • 0
  • 0
  • 0
  • 1.2E-10
  • 4.8E-11
  • -3.376E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1616
  • 13.98
  • 15.91
  • 5.567
  • 43.31
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3291
  • 0
  • 0
  • 2.99
  • 2.738
  • 509.1
  • -215.8