Close Go back Collapse all sections
Process Data set: SAVE VSR 700 (en) en

Key Data Set Information
Location LT
Geographical representativeness description Europe
Reference year 2024
Name
SAVE VSR 700
Technical purpose of product or process SAVE VSR 700 residential air handling unit for balanced ventilation with integrated controls, EC fans and high efficiency rotary heat exchanger.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-08-21" - "2029-08-21"
Technological representativeness
Technology description including background system For complete technical data including dynamic energy performance calculations, please refer to the product page on Systemair.com

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1995
  • 4.645
  • 0.01205
  • 0.3076
  • 0.635
  • 0.3054
  • -93.33
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1996
  • 4.645
  • 0.01205
  • 0.3076
  • 0.635
  • 0.3054
  • -93.33
Input
  • 8717
  • 369.3
  • 2.228
  • 21.49
  • 4.174
  • 3.741
  • -388.8
Input
  • 135.9
  • 0
  • 0
  • 0
  • -116.1
  • 0
  • 0
Input
  • 8853
  • 369.3
  • 2.228
  • 21.49
  • -111.9
  • 3.741
  • -388.8
Input
  • 88.54
  • 0
  • 0.001094
  • 0
  • 0.00004068
  • 0.005029
  • 0.587
Input
  • 24.17
  • 0.1625
  • 0.0002965
  • 0.011
  • 0.01382
  • 0.00281
  • 1.039
Input
  • 7.427
  • 0.5445
  • 0.004363
  • 0.03935
  • -0.0001497
  • 0.05364
  • 28.38
Input
  • 11.2
  • 0.04202
  • 0.0001147
  • 0.002298
  • 0.02335
  • 0.004494
  • -0.394
Output
  • 4.29
  • 0.0202
  • 0.00006558
  • 0.001108
  • 0.001032
  • 0.2984
  • -0.1236
Output
  • 193.7
  • 32.09
  • 0.002638
  • 1.045
  • 0.4417
  • 18.26
  • -15.48
Output
  • 0.03189
  • 0.002521
  • 0.00001547
  • 0.0001464
  • 0.000001068
  • 0.000008993
  • -0.0005042
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 20.58
  • 0
  • 0.001074
  • 0
  • 101.7
  • 0.0003641
  • -0.02297
Output
  • 2.248
  • 0
  • 0.000003331
  • 0
  • 1.985
  • 0.000005783
  • -0.003025
Output
  • 1.492
  • 0
  • 0.00001142
  • 0
  • 2.607
  • 0.0002296
  • -0.007411
Output
  • 22.57
  • 0
  • 0.0001728
  • 0
  • 39.45
  • 0.003474
  • -0.1121

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 8835
  • 369.3
  • 2.228
  • 21.49
  • 4.173
  • 3.74
  • -388.9
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.4392
  • 0.0004051
  • 2.484E-7
  • 0.00003925
  • 0.000004397
  • 0.00000198
  • -0.002354
Acidification potential, Accumulated Exceedance (AP)
  • 6.456
  • 0.0732
  • 0.001693
  • 0.004084
  • 0.00223
  • 0.0013
  • -0.5482
Global Warming Potential - biogenic (GWP-biogenic)
  • 2.847
  • 0.009737
  • 0.00003035
  • 0.0005882
  • 0.00265
  • 0.0002242
  • -0.07333
Global Warming Potential - fossil fuels (GWP-fossil)
  • 664.2
  • 22.73
  • 0.1619
  • 1.421
  • 7.855
  • 0.3715
  • -40.57
Global Warming Potential - total (GWP-total)
  • 670.2
  • 22.75
  • 0.1619
  • 1.422
  • 7.858
  • 0.3722
  • -40.87
Global Warming Potential - land use and land use change (GWP-luluc)
  • 3.162
  • 0.006926
  • 0.00001276
  • 0.0005058
  • 0.0002572
  • 0.0004778
  • -0.2211
  • 672.5
  • 22.75
  • 0.1619
  • 1.422
  • 7.857
  • 0.3749
  • -53.16
Eutrophication potential - freshwater (EP-freshwater)
  • 0.06593
  • 0.0001809
  • 5.893E-7
  • 0.00001135
  • 0.0000193
  • 0.000004033
  • -0.00441
Eutrophication potential - marine (EP-marine)
  • 0.7907
  • 0.01603
  • 0.0007474
  • 0.0008081
  • 0.0006722
  • 0.0005958
  • -0.05203
Eutrophication potential - terrestrial (EP-terrestrial)
  • 17.89
  • 0.1788
  • 0.008201
  • 0.009039
  • 0.007259
  • 0.004632
  • -0.6124
Photochemical Ozone Creation Potential (POCP)
  • 2.855
  • 0.0702
  • 0.002255
  • 0.003463
  • 0.001874
  • 0.00146
  • -0.2329
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00006047
  • 0.000005481
  • 3.499E-8
  • 3.219E-7
  • 1.078E-7
  • 4.737E-8
  • -0.01553
Water (user) deprivation potential (WDP)
  • 1.193E+5
  • 283.1
  • 0.4733
  • 20.78
  • 21.34
  • 18.08
  • -4491

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 38.49
  • 1.614
  • 0.009547
  • 0.09391
  • 0.01821
  • 0.01546
  • -0.5216
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00006196
  • 0.000002088
  • 4.481E-8
  • 8.7E-8
  • 2.154E-8
  • 2.396E-8
  • -0.000003826
Potential Soil quality index (SQP) 2
  • 1.072E+4
  • 423.3
  • 0.2827
  • 15.03
  • 1.499
  • 10.85
  • -78.39
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.00005439
  • 2.61E-7
  • 1.105E-9
  • 1.74E-8
  • 1.943E-8
  • 2.07E-7
  • -0.000001159
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.000003314
  • 0
  • 0
  • 0
  • 9.44E-10
  • 3.277E-9
  • -2.047E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 3.609E+4
  • 2.7E+2
  • 1.218
  • 15.93
  • 45.41
  • 564.7
  • -4827