| Key Data Set Information | |
| Location | CH |
| Geographical representativeness description | Europe |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage. |
| Technical purpose of product or process | This Environmental Product Declaration is a “specific product with extrapolation rules EPD”, and the declared product is the Air-insulated switchgear UniGear ZS1 12.12.32 500mm IF, BT (w/CT, VT, CB-), including related accessories and packaging. General technical information of the Air-insulated switchgear UniGear ZS1 12.12.32 500mm (w/CT, VT, CB) are presented below. UniGear ZS1 12.12.32 500mm (w/CT, VT, CB) Ratings Rated voltage [kV] 12 Rated feeder current [A] 1250 Rated short time withstand current [kA] 31.5 Size Width 500mm Components Circuit Breaker VD4/P p135 12kV 1250A 31.5kA Current Transformer TPU 43.13 1000//1/1 A Voltage Transformer TJCN 4 - 11000/v3//110/v3/110/3 The UG ZS1 12.12.32 500mm manufactured by ABB Brno located in Czech Republic. The manufacturing site is certified according to the following standards: - ISO 9001:2015 – Quality Management Systems - ISO 14001:2015 – Environmental Management Systems - ISO 45001:2018 – Occupational Health and Safety Management Systems The constituent materials of UG ZS1 12.12.32 500mm IF (with TPU43.13, TJCN4, VD4/P 12.12.32 p.135) is presented below. Weights of VD4/P 12.12.32 p.135, 3 pcs of TPU 43.13 and 3 pcs of TJCN4 are included to bellow table. Type Material Weight [kg] Weight % Metals Aluminum 3.30 0.53 Copper 64.29 10.41 Steel, stainless 165.16 26.76 Steel (Magnelis®) 270.09 43.75 Brass 3.29 0.53 Other metals 0.38 0.06 Plastics Plastics (PA, PP, PVC, ABS) 37.46 6.07 Rubber 3.97 0.64 Others Epoxy resin 63.55 10.3 Safety glass 1.01 0.16 Ceramics 0.9 0.15 Others 3.89 0.63 Total 617.28 100 |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Both primary and secondary data are used. The main sources for primary data are the bill of materials, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. According to PCR, the cut-off criteria can be set to a maximum of 2 % of the overall environmental impacts. In this LCA, stickers have been excluded as their weights are negligible. Process black oxide and phosphate conversion coating have also been excluded due to the model complexity and unavailability of data. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-01-31 - 2030-01-31 |
| Technological representativeness | |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-08-29T22:00:39 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 148127d6-f9d9-4c0f-88bf-339325758670 |
| Date of last revision | 2025-07-02T11:57:37.4867473Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-8899-7606 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle