| Key Data Set Information | |
| Location | NO |
| Geographical representativeness description | Nordic countries. |
| Reference year | 2024 |
| Name |
|
| Use advice for data set | The system boundaries for this EPD is module A1-A5 and C2. A1: Packaging is not included due to different packaging scenarios. A4: Distance for transport from manufacturer to building site is set to 300 km by truck or lorry. This distance is given in new PCRs as default value for Norway. A5: Installation is not included due to different installation methods. Specific EPDs including A5 can be provided on request. C1, C3, C4 and D: Included as zero due to various demolition scenarios, however it is assumed that after 100 years of service life, all end-of-life product is expected to be collected from demolition site (C1). Most of the product materials is assumed to be recycled (C3) while the rest is assumed to be incinerated (C3) and/or landfilled (C4). C2: Transportation distance to nearest waste handling facility is estimated to be 85 km by truck. This distance is given in new PCRs as default value for Norway. |
| Technical purpose of product or process | Nofi VAKOS PE pumping station is in principle, a buried vertical tank equipped with pumps, associated pipe system, power supply and control. Normally used for the delivery of drinking water, industrial water, storm water and waste water to consumers or sewage treatment plants. It is usually the municipalities that own and operate this type of facility, or larger private water and sewage treatment plants. Further information can be found at https://www.nofivakos.no/pe-pumpestasjoner This EPD applies only to the Pumping station produced by Haplast AS, and does not include technical installations (pump, valve, ladder, pipes, etc.) Calculations for this EPD is done based on an average pumping station with size: - Di 2000 - H 5000 - 3x3 m top deck - 1 middle deck Project specific EPD can be delivered on request. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on registered EPDs according to EN 15804, Ostfold Research databases, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-08-23" - "2029-08-23" |
| Technological representativeness | |
| Technology description including background system | https://www.nofivakos.no/ |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-09-18T19:50:16 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 0b42d135-c4d1-48a2-89c3-c26ead37ddf2 |
| Date of last revision | 2024-08-20T11:01:02.964317Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-7336-6726 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle