Close Go back Collapse all sections
Process Data set: Component EPD Surnadal: PVC insulated and PVC sheathed house wiring cable for open, fixed installation indoors and outdoors PR 2x1,5/1,5 (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norway, Sweden, Finland
Reference year 2024
Name
Component EPD Surnadal: PVC insulated and PVC sheathed house wiring cable for open, fixed installation indoors and outdoors PR 2x1,5/1,5
Use advice for data set The analysis is a cradle-to-gate (A1 - A3) study, with option A4 transport to market. It includes the extraction and production of raw materials, transportation to the production site, the production process itself and transport to the market. A5, installation, is included for the transport of packaging waste from the construction site and the treatment of this waste - not the installation of the products. The material data set used in A1 is generated from the cradle to gate part (A1-A3) of a published EPD from Amo Installationskabel AB. Transport in A2 is the specific transport of the material from Amo Installationskabel AB to Pipelife Norge AS, Surnadal.
Technical purpose of product or process PR 2x1,5/1,5 is a PVC insulated and PVC sheathed house wiring cable for open, fixed installation indoors and outdoors. The insulation of the conductor shall be protected against UV light. Used by Pipelife Norway in Powerline prewired electro pipes for hidden electrical installations inside walls. More information is found on https://www.pipelife.no/
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is not allocated among internally or externally purchased, components which are not further processed, only handled and assembled, before leaving Pipelife Norge AS, Surnadal. Cut-off criteria: All raw materials and all the essential energy are included.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-11-18" - "2029-11-18"
Technological representativeness
Technology description including background system Product standard: EN 61386. See our product catalogue on our website: https://www.pipelife.no/

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 11.4
  • 0.003535
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 11.4
  • 0.003535
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 53.05
  • 0.247
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 11.47
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 64.52
  • 0.247
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.001267
  • 0.0001265
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.004532
  • 0.0004522
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.03598
  • 0.00002641
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0001276
  • 0.00001274
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.1414
  • 0.01201
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00001686
  • 0.000001682
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 64.84
  • 0.247
  • 0
  • 0
  • 0
  • 0
  • 0
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001403
  • 4.512E-7
  • 0
  • 0
  • 0
  • 0
  • 0
Acidification potential, Accumulated Exceedance (AP)
  • 0.03728
  • 0.00004694
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.02101
  • 0.000006761
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.877
  • 0.01633
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - total (GWP-total)
  • 3.909
  • 0.01635
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.01096
  • 0.000005814
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.834
  • 0.01635
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - freshwater (EP-freshwater)
  • 0.000009576
  • 1.305E-7
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - marine (EP-marine)
  • 0.002955
  • 0.000009289
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.03108
  • 0.0001039
  • 0
  • 0
  • 0
  • 0
  • 0
Photochemical Ozone Creation Potential (POCP)
  • 0.0111
  • 0.0000398
  • 0
  • 0
  • 0
  • 0
  • 0
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.713E-8
  • 3.7E-9
  • 0
  • 0
  • 0
  • 0
  • 0
Water (user) deprivation potential (WDP)
  • 3.508
  • 0.2389
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01082
  • 0.001079
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 1.002E-8
  • 1E-9
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 1.731
  • 0.1728
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.004E-9
  • 2E-10
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1.834
  • 0.1831
  • 0
  • 0
  • 0
  • 0
  • 0