| Key Data Set Information | |
| Location | NO |
| Geographical representativeness description | Nordic |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | Cradle to Gate. The following stages have been declared: A1-A4 |
| Technical purpose of product or process | IFX LX 90 building wire to be used for indoor installations, non protected, installed in trunk or pipe on wall, sealing or in deck. Outdoor installed - mechanical protection is required. Current rating shall be based on maximum 70° ambient temperature. Packaging solution result in a "Non spinning" outlook. General: Factory Standard |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging! |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-04-10 - 2030-04-10 |
| Technological representativeness | |
| Technology description including background system | Construction standards Factory Standard Conductor Rigid bare copper EN60228 class 1 Insulation - conductor XLPE Conductor marking Colored acc. Cenelec Conductor laying Twisted Bedding PVC Jacket PVC - lead free White Marking PFXP LX 500V + Meter marking Voltage - nominal Uo/U 300/500V Voltage - test 2000V Max Conductor temperature operation 90° Max temperature at Short circuit 5s max 250° Resistance insulation 1000M?*Km Resistant to fire performance EN 50265-2-1; EN 60332-1-2 CPR EN 50575 compliance Eca DoP DOP-0015/20 Temperature - operation -30 to + 70oC Temperature - installation -5 to + 700C Bending radius 5 x D |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-05-19T10:41:39 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 04d9966a-7387-4df4-87dc-83c44d8d919e |
| Date of last revision | 2025-04-09T11:53:25.3195945Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-9728-9651 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |